Lot 19 Martin Close Subdivision

Report 1 Downloads 86 Views
4

MANLY

2

2

6

* All illustrations & floor plans are artistic impressions & should only be used as a visual aid.

LOT 19 SIZE 351.00m2 PRICE $ 426,200

DESIGN MANLY SIZE 199.78m2 PRICE $ 351,300

$777,500

**Package price is subject to availability & subject to change without notice. Furniture shown is for illustrative purpose only & is not included in the purchase price.

Lot 19 Martin Close Subdivision

SOUTH MORANG House & Land Package

__________________________________________________________________________________________________________________________________________________________________________ * All illustrations & floor plans are artistic impressions & should only be used as a visual aid ** Listed lot width is to be used as a guide only and is dependent on the estate plan of the development where the lot is located

CONTRACT HOUSE & LAND PRICING Site Details Property Address: Lot 19 Martin Close Subdivision

Suburb: SOUTH MORANG

Site Area: 351 sqm

Frontage: 10.5 Lm

House Detail

4

2

2

SITE AND ESTATE TRIGGERED COSTS Future NBN connectivity Site cut and Soil removal for 1.5m to 2.0m fall across house pad P Class Soil Engineered retaining to form a level pad Provisional Sum

$500.00 $3,120.00 $6,200.00 $38,480.00

Costs associated with Zero Boundary

$700.00

Piers to natural ground in fill zone

$1,170.00

Removal of surplus site scrape materials

$1,200.00

Bushfire Attack Level 12.5

$4,500.00

Drop Edge Beam on Garage Wall SubTotal HOUSE INCLUSION UPGRADES Ext finish: Brick veneer construction with multiple materials for a high quality finish - see sales plans Hotwater: Solar hot water system with gas booster 5 star Community Infrastructure Levy Additional garage area to comply with FF Setback

$1,583.00 $57,453.00

$2,088.00 $3,776.00 $1,000.00 $2,176.00

Large Gable

$949.00

Frosted glass window in habitable room = 2

$750.00

SubTotal

$10,739.00

TOTALS House Total

$351,300.00

Land Price

$426,200.00

Package Total

$777,500.00

For Sale Signature

Signature

Date

Date

Printed Date 29/03/2018 04:05

ITEMS INCLUDED IN THE CONTRACT PRICE - Contract: Full Turnkey - Roof: Shaped profile concrete tile - Ceiling height: 2.44m - Kitchen bench tops: 20mm Engineered stone kitchen bench tops - Hotplate: Stainless steel 60cm Gas cooktop - Outdoor Living Area: Under Roof if included on plans - Lighting/fan package: White downlights throughout house - Kitchen: Stainless Steel Appliances - Dishwasher: Included to match appliances - Hotwater: Solar with Gas Booster - Security package: Flyscreens to windows - Air conditioning: 1 Split System & ducted gas heating - Internal doors: Flush Panel - Wardrobes: Full Height Built-ins For Easy Storage - Tapware: Flick Mixers - External Concrete: Coloured Concrete - Window Cov: Roller Blinds To Windows & Sliding Doors Excl. Wet Areas - Floor Coverings: Tile & Carpet Flooring - Metal Letterbox - Internal Door Handles: Whitco Bevel Satin Chrome - Architrave & Skirting: Pencil Round - Landscaping: Full Package - Landscaping: Standard landscaping package - Fencing to complete property

WARRANTIES - Full Internal and External Commercial quality clean on completion - 6.5 years structural guarantee - 12 months guarantee on materials and workmanship - Appliances covered by manufacturers warranty

Lot 19 Martin Close Subdivision, SOUTH MORANG VIC 3752

PS812698B 9 6 ° 3 4'40 "

3

1

3

0" 4 '4 1° 3 24

MGA 94 ZONE 55

14 4 . 13 R- 6 " AD 5.634 '4 0 RO 1° 14

1 8 6 ° 3 4 '4 0 "

1

² . 5m

38

ENLARGEMENT

12

E - 1

12 . 5 5

25 26

1 3 8 .9 8 2 7 6 °3 4' 40 "

Farren Group

74 Maribyrnong Street Footscray 3011

Creating New Boundaries

Phone 9689 1000 Fax 9689 1002 [email protected]

LAND SURVEYING - TOWN PLANNING - HYDROGRAPHIC MAPPING

SCALE 1:750

7.50

0

41 8 m²

9 6 °3 4' 40 " E - 2 ( 3 3 . 47 )

41 8 m²

( 3 3 . 47 )

E - 2

7.50

15

22.50

LICENSED SURVEYOR:

ROBERT J. SIGNORINI

9 6 °3 4' 40 " 3 3 . 48

3 5 2 m²

9 6 °3 4' 40 " 3 3 . 48

32

31

41 9 m²

30

43 2 m²

29

45 6 m²

28

48 1

27

9 6 °3 4' 40 " 3 3 .5 3

9 6 °3 4' 40 " 3 5 .5 1

9 6 °3 4' 40 " 3 7 . 48 m² E - 2

3 9 . 46

1 0 .5 0

CLOSE

1 0 .5 0

1 0 .5 0

M A RTI N

3 5 2 m²

33

1 0 .5 0

9 6 °3 4' 40 " 3 3 . 48

1 0 .5 0

3 5 2 m²

34

1 0 .5 0 9 7 .1 6 1 8 6 ° 3 4 '4 0 "

9 6 °3 4' 40 " 3 3 . 48

1 0 .5 0

2 7° 2 1 5 .5 7 ' 2 1 0 .5 0 6 °3 5 '

30

LENGTHS ARE IN METRES

35

9 6 °3 4' 40 " 3 3 . 48

3 5 2 m²

36

0 .3 4

41 8 m²

9 6 °3 4' 40 " E - 2 ( 3 3 . 47 )

9 6 °3 4' 40 " 3 3 . 48

37

1 2 .1 6

41 8 m²

9 6 °3 4' 40 " E - 2 ( 3 3 . 47 )

9 6 °3 4' 40 " 3 3 . 48

3 5 2 m²

1 0 .5 0 6 °3 5 ' 1 0 .5 0 6 °3 5 ' 1 0 .5 0 6 °3 5 ' 1 0 .5 0 6 °3 5 '

3 5 1 m²

9 6 °3 4' 40 " E 2 ( 3 3 . 47 )

3 5 2 m²

38

1 2 .6 5

24

3 5 1 m²

9 6 °3 4' 40 " E - 2 ( 3 3 . 47 )

1 0 .5 0 6 °3 5 '

1 0 .5 0

23

3 5 1 m²

1 2 .5 0 6 °3 5 '

1 0 .5 0

6 ° 3 4 '4 0 " 13 4 1 0 .5 0 1 0 .5 0

22

3 5 1 m²

9 6 °3 4' 40 " E 2 ( 3 3 . 47 )

9 6 °3 4' 40 " E - 2 ( 3 3 . 47 )

9 6 °3 4' 40 " 3 3 . 48

3 5 2 m²

1 0 .5 0 6 °3 5 '

1 0 .5 0

1 0 .5 0 16

21

3 5 1 m²

9 6 °3 4' 40 " E - 2 ( 3 3 . 47 )

43 7 m²

1 2 .6 6 3 8 .3 1 1 7 7 ° 3 6 '2 0 "

3 0 0 m²

E - 1

12

4

6 °3 5 ' (2 5 )

6 °3 5 ' (2 5 )

3

3 0 0 m²

6 °3 5 ' (2 5 )

8 .5 5

20

3 5 1 m²

9 6 °3 4' 40 " E - 2 ( 3 3 . 47 )

2 3 .9 5

(1 2 . 6 6 )

12

2 E - 1

16

46 . 0 5

6 5 .6 ° 3 5 ' 51

3 0 6 m²

16

3 3 8 m²

8 .5 5

19

3 5 1 m²

9 6 °3 4' 40 " E 2 3 3 . 47

1 2 .5 0 6 °3 5 '

12

5

R-1 3041m²

5' 1° 3 14 5.66

12

1

(2 5 )

6

ROA D 02 9 6 °3 4' 40 "

1 3 .5 0

13 . 5 0

3 3 1 m²

18

9 6 °3 4' 40 " ( 3 3 . 47 )

1 2 .5 0 6 °3 5 '

12

46 . 0 5 9 6 °3 4' 40 "

E - 1

14

3 2 4m²

1 2 .5 0

13 . 5 0

7

1 2 .5 5

1 2 .5 0

3 2 4m²

6 °3 5 ' 2 7

2 7

8

5 0 .0 5 12

6 °3 5 ' 2 7

3 6 5 m²

9

1 2 .5 0

9 6 °3 4' 40 " 12

1 3 .5 0

6 °3 5 ' 2 7

6 ° 3 4 '4 0 " 13 8

14

7 0 1 m²

1 2 .5 0

9 6 °3 4' 40 " 5 0 .0 5

17

1 0 .5 0

10

ROA D 01

14

7 0 1 m²

11

16

14

9 6 °3 4' 40 " 5 0 .0 5

12 . 5 5

14 8 9 m 6 ° 3 4 '4 0 "

14

7 0 1 m²

RE SE RVE N o .1 5 1 7 m²

( 1 2 .5 0 ) 6 °3 5 '

12 5 0 .0 5

E - 1

2 3

12 9 6 °3 4' 40 "

3 43 m²

E - 1

3 5

' 35 5 1 ° 5 .6 6 16

(2 1) 6 °3 5 '

13 . 5 0

3 3 6 m²

E - 1

9 6 ° 3 4'40 " 13 0

2 4

15

6 °3 5 ' (2 8 )

6 °3 5 ' (2 8 )

14

3 3 6 m²

3 7 8 m²

E - 1

8 .5 5

(2 4 )

13

6 °3 5 ' (2 8 )

(2 8 )

12

12

1 0 .5 0

12

5' 1 °3 1 4 5.66

1 3 .5 0

PLA CE

1 0 .5 0

GI RV A N

SEE ENLARGEMENT

SCALE 1:125

REF: 10637 ORIGINAL SHEET VERSION: 01 SIZE: A3

SHEET 2

NOTE

Structural footings are to be a minimum 1200mm horizontally from sewer and stormwater infrastructure including house Connections AND be founded a minimum 300mm below the zone of influence.

IMPORTANT NOTE:

PLANS AND COSTING ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; COVENANT/CERTIFICATION/COUNCIL FEEDBACK AND ENVIRONMENTAL OVERLAYS/HAZARDS.

NBN estate - National Broadband Network. Please see the job supervisor to ensure the correct method of installation is implemented.

All floor levels and other site specific details are design details only and are subject to change due to construction tolerances and site variables. DISCLAIMER: Site levels, services and existing structures are supplied by others, therefore Impact Homes takes no responsibility for their accuracy. The builder should verify all details before commencing work.

157.00

Charcoal Coloured Concrete Driveway by Builder

158.00

Approx. 800mm High Timber Sleeper Retaining Wall where required

AC

AC Condenser

Solar Panel

Stormwater Line

Sewer Line

1,800

FF SETBACK

2,300

33.47

Gas Cylinder Solar HWS

Stormwater Line

4,000 SETBACK

*Solar Panels*

Solar HWS

GF WALL

2,300

1,200

POS = 55m²

GF SETBACK

CUT

FF WALL

3,000 SETBACK

Crossover by Developer Sewer H/C Sewer Line

Gas Line Water Line

FILL

Downpipe Elect Meter Box Gas Meter Box Int Fuse Box Gas HWS

10.50

10.50

Coloured Concrete 29m²

4,000

5,000 GARAGE 4,000 WALL

EMT

Proposed RL: 158.00 FFL: 158.40

1,282

612

200

1,800 FF WALL

1,800

1,800

1,200

GF WALL

2,000

GF SETBACK

GF Setback Line FF Setback Line

33.47

FF SETBACK

Drop Edge Beam Stormwater H/C

Stormwater Pit

Muster Point

Batter (with direction of fall)

All Required Fencing to be Timber Rail & Paling 1800H with access gates as shown. Roll Under 1 in 6 1500

159.00

1 in 6 1500

1 in 20 1500mm

Min FFL:

157.83

Site Plan

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440 2440 25.00° Concrete Tile 450

02 #

SITE DATE

DESCRIPTION

1 : 200

CLIENT SIGN.

DESIGN: Manly (MOD)

AMENDMENTS

SP

Parish: County: Map Ref: Local Authority: Whittlesea City Council Wind Rating: Area of Land: 351m2 Site coverage: 37% Job Number: 135545 Prelim Plans Issue: 26/03/2018 Date:

CONSTRUCTION DET.

Lot 19 Martin Close Subdivision . SOUTH MORANG . VIC . 3752

DRAWING PROPERTY DETAILS DESCRIPTION

CLIENT

1 : 200

SITE ADDRESS

1

1:4

500

Site Boundary

Stormwater Line

N

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

NOTE

WINDOWS

Floor Areas

PLANS AND COSTING ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; COVENANT/CERTIFICATION/COUNCIL FEEDBACK AND ENVIRONMENTAL OVERLAYS/HAZARDS.

Unless dimensioned all windows are to be centred to the room in which they are located. IF a window is NOT centred OR dimensioned - ASK the job supervisor

GF Living Garage Alfresco Porch FF Living

75.09 m² 40.39 m² 9.63 m² 3.18 m² 71.49 m² 199.78 m²

Ceiling Schedule GF Ceiling FF Ceiling

102.76 m² 65.96 m² 168.72 m²

19,990 18,990

1,000

12,510 240

7,550

90

1,940

90

240

7,550

90

1,940

90 870 90

240 1,000

6,000

240 1,000

Material

Area

Finishes - Interior - Plasterboard 550.07 m²

DP 1806 SW

1806 SW

1806 SW DP

Solar HWS

2,700 240

3,760

3,790

240

3,760

90 920 90 930 90 870 90 3,540

3,790

DP

240 1,600

6,480

1,600 240

240 6,000

90 510 90 90 1,520

Porch Covercrete

Elect & Gas MB

1,800

*Gas Booster*

3,790

820

Tiles

UP

2,190

Entry

820

1,430

820

Tiles

Tiles

240

Robe

RA

Meals

HC

1,600

1500 WSD

240

820

90

REF 2121 SGD

Covercrete

8,000

dwp

Pwd 930

Alfresco

Garage

Carpet

720

3,040

Bed 4

820

Tiles

3,640

Kit

Tiles

DP

Ldy

Gas CT Elect Ov

2,430

mw

1824 SFS

Family

240

1,100

3,640

AC

1215 SW

2115 SGD

DP

240 1,000 90 1,100 90

1806 SW

DP

300

6,000

90

2100 x 4800 Panel Lift

1,600

90

820 1/2 Glass

AC

PTY

HC

240 90

3,380 240 2,300

240 1,000 90 1,100 90

240

1,790

1,600

1218 SW

DP

1,990

3,860

8,000

2,750

Wall Material Takeoff

240 1,000

7,350

1,560

240

1,600

600

2,540

6,240

1,790 90

90

6,240

2,860

240

1,740

10,730

1,000 350 4,470

2,380

1,000 1,000

19,990

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440 2440 25.00° Concrete Tile 450

03a GROUND FLOOR #

DATE

DESCRIPTION

1 : 100

CLIENT SIGN.

DESIGN: Manly (MOD)

AMENDMENTS

SP

Parish: County: Map Ref: Local Authority: Whittlesea City Council Wind Rating: Area of Land: 351m2 Site coverage: 37% Job Number: 135545 Prelim Plans Issue: 26/03/2018 Date:

CONSTRUCTION DET.

Lot 19 Martin Close Subdivision . SOUTH MORANG . VIC . 3752

DRAWING PROPERTY DETAILS DESCRIPTION

CLIENT

1 : 100

SITE ADDRESS

1

Ground Floor Plan

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

NOTE

WINDOWS

Floor Areas

PLANS AND COSTING ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; COVENANT/CERTIFICATION/COUNCIL FEEDBACK AND ENVIRONMENTAL OVERLAYS/HAZARDS.

Unless dimensioned all windows are to be centred to the room in which they are located. IF a window is NOT centred OR dimensioned - ASK the job supervisor

GF Living Garage Alfresco Porch FF Living

75.09 m² 40.39 m² 9.63 m² 3.18 m² 71.49 m² 199.78 m²

Ceiling Schedule GF Ceiling FF Ceiling

Wall Material Takeoff

12,190 4,950

3,390

2,880 3,460

90

3,960

90

90

3,960

90

RA

Linen

Carpet

Carpet SR

DP

DP 0606 SW

0921 FG

1,890 3,480

90 930 90

2,810

90

90

1,510

4,410

90

240 4,400

175 4,220

2,480

90 51090

90

90

WIR

Linen

1000 WSD

Ens

UP

Ducted Heating Unit

900

3,820

2,800

Carpet 720

6,400

820

240

720

Carpet

1,520

820

1000 WSD

SR

Master Bedroom

820

90

Carpet

2,010

Bed 3

720

Bath

0618 SW

90

WC

DP

1806 AW

Robe

1500 WSD

Robe

1500 WSD

1018 AW

*Frosted*

1215 AW

Carpet

0612 SW

240

*Frosted*

0606 SW

Bed 4

90

Area

3,450

DP

DP

240 1,670

1,690

90 1,040 90 1,940 240 1,000 90

240 1,000 90 965 90 885 90 1,020 90

6,400

150

Material

Finishes - Interior - Plasterboard 550.07 m²

90 1,120 90 800 90 930 90

90

90 90 930 90 90 490 490 90 930 90

90

1818 AW

7,800

2,810

7,150

1806 AW

90

102.76 m² 65.96 m² 168.72 m²

1,880

6,810

3,290

90 90

90

1,560

90

3,290

90

1,560

90

3,380

2,000

3,380

12,190

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440 2440 25.00° Concrete Tile 450

03b FIRST FLOOR #

DATE

DESCRIPTION

1 : 100

CLIENT SIGN.

DESIGN: Manly (MOD)

AMENDMENTS

SP

Parish: County: Map Ref: Local Authority: Whittlesea City Council Wind Rating: Area of Land: 351m2 Site coverage: 37% Job Number: 135545 Prelim Plans Issue: 26/03/2018 Date:

CONSTRUCTION DET.

Lot 19 Martin Close Subdivision . SOUTH MORANG . VIC . 3752

DRAWING PROPERTY DETAILS DESCRIPTION

CLIENT

1 : 100

SITE ADDRESS

1

First Floor Plan

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

NOTE PLANS AND COSTING ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; COVENANT/CERTIFICATION/COUNCIL FEEDBACK AND ENVIRONMENTAL OVERLAYS/HAZARDS.

Solar Panels

300 2,440

NGL

120

Approx. 800mm High Timber Sleeper Retaining Wall where required

PGL

2

Rendered Brick

7,000 OVERALL BUILDING HEIGHT

Site Boundary

Site Boundary

Scyon Linea

5,440 OVERALL WALL HEIGHT

Scyon Linea Feature Colour

Brick Above Openings

2,700 GARAGE WALL HEIGHT

1 : 100

2,440

1

Elevation A

Feature Brick

Rendered Brick to Piers

Elevation B 1 : 100

DESIGN: Manly (MOD) Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440 2440 25.00° Concrete Tile 450

04 # AMENDMENTS

Parish: County: Map Ref: Local Authority: Whittlesea City Council Wind Rating: Area of Land: 351m2 Site coverage: 37% Job Number: 135545 Prelim Plans Issue: 26/03/2018 Date:

CONSTRUCTION DET.

SP

Site Boundary

Easement

7,000 OVERALL BUILDING HEIGHT

PGL

Face Brick

DRAWING PROPERTY DETAILS DESCRIPTION

Lot 19 Martin Close Subdivision . SOUTH MORANG . VIC . 3752

NGL

ELEVATION 1 DATE

DESCRIPTION

1 : 100

CLIENT SIGN.

Feature Brick

CLIENT

Rendered Brick to Piers

2,440

2,741 GARAGE WALL HEIGHT

300

00°

5,440 OVERALL WALL HEIGHT

25.

*Frosted*

2,440

Scyon Linea Feature Colour

SITE ADDRESS

Site Boundary

F.C. Sheeting Above All Brick Openings

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

NOTE PLANS AND COSTING ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; COVENANT/CERTIFICATION/COUNCIL FEEDBACK AND ENVIRONMENTAL OVERLAYS/HAZARDS.

Solar Panels

Site Boundary

Scyon Axon

2,440

300

*Frosted*

Site Boundary

F.C. Sheeting Above All Brick Openings

1 : 100

2,440

1

Elevation C

NGL PGL

Face Brick

400mm Garden Edge

1 : 100 Scyon Axon

Site Boundary

2,440

Easement

*Solar Panels*

2,440

300

F.C. Sheeting Above All Brick Openings

NGL

Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440 2440 25.00° Concrete Tile 450

04a ELEVATION 2 #

DATE

DESCRIPTION

Rendered Brick to Piers

1 : 100

CLIENT SIGN.

DESIGN: Manly (MOD)

AMENDMENTS

SP

Parish: County: Map Ref: Local Authority: Whittlesea City Council Wind Rating: Area of Land: 351m2 Site coverage: 37% Job Number: 135545 Prelim Plans Issue: 26/03/2018 Date:

CONSTRUCTION DET.

Lot 19 Martin Close Subdivision . SOUTH MORANG . VIC . 3752

Rendered Brick

Face Brick

DRAWING PROPERTY DETAILS DESCRIPTION

CLIENT

PGL

SITE ADDRESS

Site Boundary

2

Elevation D

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

NOTE

Electrical Legend

IMPORTANT NOTE:

PLANS AND COSTING ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; COVENANT/CERTIFICATION/COUNCIL FEEDBACK AND ENVIRONMENTAL OVERLAYS/HAZARDS.

Elect Meter Box Gas Meter Box Fuse Box (Int) Gas HWS

NBN estate - National Broadband Network. Please see the job supervisor to ensure the correct method of installation is implemented.

Solar HWS AC AC

AC Condenser AC Head Unit Gas Cylinder

Solar Panel

Ducted Heating Throughout

Ceiling Fan Ceiling Fanlight (Fluro)

DP

Double GPO, Batten Light and Switch to be placed above Roof Access in ceiling cavity.

Exhaust 3 in 1 Exhaust Fan AC

HC

AC

S mw

Smoke Detector

DP

PTY

DP

Exhaust Fanlight

Sgl Fluro Tube 18w Dbl Fluro Tube 36w

R

Gas CT Elect Ov dwp

Sgl Globe Fluro Oyster Dbl Globe Fluro Oyster

DP

Downlight 12V Low Voltage

REF

Downlight 240V Downlight 12V Pendant

2W

RA

Downlight Low V Fluro Eyeball Light

2W

Wall Light

UP

Bunker Light (External)

2W

Flood Light (Eave)

HC

DP

DP

Solar HWS

Flood Light (Wall)

Elect & Gas MB

DP

*Gas Booster*

Sensor Sensor Flood Light Batten Holder R

Single GPO Double GPO Roof Single GPO Waterproof Single GPO Waterproof Doube GPO Gas Outlet

Electrical Fixture Schedule Count

Pay TV Point

37 17 4 1 1 3 1 4 2 1 1 72

Phone Point Data Point Door Chime Button

1 : 100

SITE ADDRESS

CLIENT

Electrical points positions subject to construction constraints

GF Electrical Plan

Lot 19 Martin Close Subdivision . SOUTH MORANG . VIC . 3752 SP

Parish: County: Map Ref: Local Authority: Whittlesea City Council Wind Rating: Area of Land: 351m2 Site coverage: 37% Job Number: 135545 Prelim Plans Issue: 26/03/2018 Date:

DESIGN: Manly (MOD) Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440 2440 25.00° Concrete Tile 450

08 # AMENDMENTS

1

Isolation Switch

CONSTRUCTION DET.

Dimmer Switch

S

DRAWING PROPERTY DETAILS DESCRIPTION

Door Chime Speaker

GF ELECTRICAL DATE

DESCRIPTION

Family Light Downlight GPO Fan Isolation Switch Service Point GPO GPO Service Point Service Point Light Point GPO

1 : 100

Type 240V Double Exhaust Fan Isolation Switch Phone Single Single Roof Smoke Detector TV Wall Waterproof Single

CLIENT SIGN.

$

TV Point

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.

NOTE

Electrical Legend

IMPORTANT NOTE:

PLANS AND COSTING ARE SUBJECT TO CHANGE UPON COMPLETION OF PROPERTY BOUNDARY IDENTIFICATION SURVEY; CONTOUR SURVEY; SURVEYED LOCATION OF NEIGHBOURING DWELLINGS; COVENANT/CERTIFICATION/COUNCIL FEEDBACK AND ENVIRONMENTAL OVERLAYS/HAZARDS.

Elect Meter Box Gas Meter Box Fuse Box (Int) Gas HWS

NBN estate - National Broadband Network. Please see the job supervisor to ensure the correct method of installation is implemented.

Solar HWS AC AC

AC Condenser AC Head Unit Gas Cylinder

Solar Panel

Ducted Heating Throughout

Ceiling Fan Ceiling Fanlight (Fluro) Exhaust 3 in 1 Exhaust Fan

Double GPO, Batten Light and Switch to be placed above Roof Access in ceiling cavity.

Exhaust Fanlight

DP

Smoke Detector

DP

Sgl Fluro Tube 18w Dbl Fluro Tube 36w Sgl Globe Fluro Oyster Dbl Globe Fluro Oyster Downlight 240V Downlight 12V Low Voltage

2W

Downlight 12V Pendant

RA

Downlight Low V Fluro Eyeball Light

Ducted Heating Unit

2W SR

Wall Light

DP

Bunker Light (External) Flood Light (Eave)

SR

UP

DP

DP

Flood Light (Wall) Sensor Sensor Flood Light

R

Batten Holder Single GPO Double GPO Roof Single GPO Waterproof Single GPO Waterproof Doube GPO Gas Outlet

Electrical Fixture Schedule Count

Pay TV Point

37 17 4 1 1 3 1 4 2 1 1 72

Phone Point Data Point Door Chime Button

1 : 100

SITE ADDRESS

CLIENT

Electrical points positions subject to construction constraints

FF Electrical Plan

Lot 19 Martin Close Subdivision . SOUTH MORANG . VIC . 3752 SP

Parish: County: Map Ref: Local Authority: Whittlesea City Council Wind Rating: Area of Land: 351m2 Site coverage: 37% Job Number: 135545 Prelim Plans Issue: 26/03/2018 Date:

DESIGN: Manly (MOD) Ceiling GF Ceiling FF Ceiling SF Roof Pitch Roof Material Eave O'hang

2440 2440 25.00° Concrete Tile 450

08a FF ELECTRICAL # AMENDMENTS

1

Isolation Switch

CONSTRUCTION DET.

Dimmer Switch

S

DRAWING PROPERTY DETAILS DESCRIPTION

Door Chime Speaker

DATE

DESCRIPTION

Family Light Downlight GPO Fan Isolation Switch Service Point GPO GPO Service Point Service Point Light Point GPO

1 : 100

Type 240V Double Exhaust Fan Isolation Switch Phone Single Single Roof Smoke Detector TV Wall Waterproof Single

CLIENT SIGN.

$

TV Point

SIGN: _______________ DATE: _____/____/_____

This plan may not be copied in part or in whole without the written permission of Impact Homes Pty Ltd. © Copyright 2014 Impact Homes Pty Ltd.