Manual Lockout & Exhaust L-O-X® Valves with Soft Start EEZ-ON®

Report 5 Downloads 31 Views
Manual Lockout & Exhaust L-O-X® Valves with Soft Start EEZ-ON®

15 Series

3-Way 2-Position Valve, Classic Port Size

F1

1, 2

3

3/8

3/4

Body Size

Valve Model Number*

1/2

Y1523B3102

CV 1-2

2-3

Weight lb (kg)

3.64

2.81

1.5 (0.7)

1/2

3/4

1/2

Y1523B4102

4.86

3.51

1.5 (0.7)

3/4

3/4

1/2

Y1523B5112

5.09

2.91

1.5 (0.7)

3/4

11/4

1

Y1523B5102

10.08

8.56

3.2 (1.5)

1

11/4

1

Y1523B6102

11.07

8.45

3.2 (1.5)

11/4

11/4

1

Y1523B7112

11.86

8.46

3.2 (1.5)

2

12

10

1 3

* NPT port threads. For BSPP threads, insert a “D” after “Y” to the model number, e.g., YD1523B3102. Valve Dimensions – inches (mm) 1.63 1.25 (41) (32)

1.88 1.75 (48) (34)

Port 2 (outlet) 2.25 (57)

Body Size 1/2

3.00 (76)

0.34 (8) Port 3 (exhaust)

Port 2 (outlet)

Port 1 (inlet)

8.96 (228)

Body Size 1

3.75 (95)

0.34 (8) Port 3 (exhaust)

2.00 (51)

4.36 (111) 6.61 (168)

2.75 (70)

Port 1 (inlet)

10.76 (273)

2.25 (57)

5.50 (140) 7.72 (196)

Accessories & Options

Port Size

Thread Type

Model Number*

3/4

Male - NPT

5500A5003

3/4 11/4

EN Connector Pinout

Pressure Switches

Silencers

Male - BSPT D5500A5003 Male - NPT

5500A7013

Avg. CV

11.5

Connection Type

Normally Open Common Normally Closed 3

Model Number* Port Threads

2

EN 175301-803 Form A 586A86 1/8 NPT M12 1153A30 1/8 NPT *Pressure switch closes on falling pressure of 5 psig (0.34 bar).

11.5 16.4

11/4 Male - BSPT D5500A7013 16.4 Pressure Range: 0 to 150 psig (0 to 10.3 bar) maximum. Flow Media: Filtered air.

F

Model Number**

Pin 4 Normally Open

Pin 2 Normally Closed

988A30

Model Number

356A30

EEZ-ON® Function

With the blue handle pulled out, the adjustable needle valve (accessed through top of handle) setting determines the rate of pressure buildup.

Valved Closed With a short push of the blue handle inward, the flow of supply is blocked and downstream air is exhausted via the exhaust port at the bottom of the valve. It is required by OSHA that the L-O-X® valves with EEZ-ON ® operation be padlocked in this position to prevent the handle from being pulled outward inadvertently when potential for human injury exists or servicing machinery.

Pin 3 Not Used

** 1/8 NPT port threads.

Multiple Lock-out Device

VALVE OPERATION

Ground

M12 Connector Pinout

Pin 1 Common

Pop-Up Indicator

1

2

1 3

2

1

2

1

3

3

Valve Open After the blue handle is pulled out and pressure downstream has gradually increased, the valve automatically changes to a fully open state, allowing full flow from inlet to downstream. Full flow is achieved at approximately 50% of inlet pressure.

STANDARD SPECIFICATIONS (for valves on this page): Construction: Spool. Mounting Type: In-Line. Ambient/Media Temperature: 40o to 175oF (4o to 80oC).

Flow Media: Filtered air. Inlet Pressure: 0 to 150 psig (0 to 10 bar).

NOTE: Per specifications and regulations, these products are defined as energy isolation devices, NOT AS EMERGENCY STOP DEVICES.

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.

F1.22

© 2016, ROSS CONTROLS®. All Rights Reserved.

Online Version Rev. 11/14/16