mariner™ stainless steel floodlight

Report 7 Downloads 99 Views
SFM

Mariner™ Stainless Steel Floodlight

class i division 2

• For use in corrosive, hosedown, marine, shipboard and hazardous environments • Integrally ballasted luminaire • SFMM series for marine applications. SFM2 for hazardous and marine applications • Restricted Breathing “RB” option for lower T-Ratings • Elevated ambient “EA” option capability up to 65°C • ”Quick release” lens latches for ease of entry, no screws • Luminaire, lens frame, lens latches – 16 gauge 316SS

• Mounting yoke, safety lens door chains, cord grip (SFMM), conduit hubs (SFM2) – SS316 • Mounting accessories – Hot dipped galvanized steel • SFMM and SFM2 Listings • UL1598 and 1598A Marine Outdoor • NEMA 4X; IP66/67 • Type approval American Bureau of Shipping (ABS) • SFM2 Listings • UL844 Standard: Class I, Div. 2 Groups A, B, C, D; Class I, Zone 2 Groups IIC, IIB, IIC • ExnR, AxnR Restricted Breathing • Pulse-rated mogul socket standard

Ordering Information

series

wattage

source

SFMM Stainless Flood Marine SFM2 Stainless Flood Class I, Division 2

15 150w PSMH, HPS 17 175w PSMH only

S High Pressure Sodium P Pulse Start Metal Halide (lamp included)

      1       2       3       4       5

255 250w PSMH, HPS 40 400w PSMH, HPS

To denote voltage, replace X with 1 - 120V; 2 - 208V; 3 - 240V; 4 - 277V; 5 - 480V; 6 - 347V Not UL 1598A Marine Listed or CSA listed for hazardous locations CSA certification applilcable to Tri-Tap® ballast only Available in SFMM only; Not suitable for hazardous locations 250w Pulse Start not available in 480V or Tri-Tap®

voltage 5

OPTIONS

480V 65 Tri-Tap® (120, 277, 347V) 8 Quad Tap® (120, 208, 240, 277V) E 220/240V, 50 Hz P 220V, 60Hz (250, 400w PSMH only)

F(X)

5

1,2,3

Fusing (specify voltage)

RS Hot re-strike (150w HPS) QS4 Quartz standby PCR(X)1,2,3,4 Photocontrol EA Elevated ambient (40°C, 55°C, 65°C) capabilities; See chart for applicable wattages RB Restricted Breathing housing allowing lower T-Ratings for SFM2 and SFMH2 Series only (Fixture provided with test port entry on side)

Ordering Information - Requires Remote Ballast Assembly on following page

sfmH2 series SFMH2 Stainless Steel Remote Head, ClassI, Division 2 Marine

entries C1 3/4” Conduit hub C3 3/4” Conduit hub restricted breathing

source

8.6" (220mm)

18.3" (465mm)

UH2 Universal head, 350w PSMH, 400w HPS, PSMH, 1000w HPS HH 1000w PSMH

19.7" (500mm) 25.2" (640mm)

11.0" (279.4mm) 4.2" (106.3mm)

10.16"(258.06mm) Center Hole 0.88" (22.2mm)

1.5" (39.75mm) 20.2" (513mm)

2 Holes 0.56" (14.3mm) 3.1" (79.5mm)

10.8" (274.3mm) 2.0" (50.8mm)

2.0" (50.8mm)

ENTRY sfmm: 3/4" CORD GRIP sfm2: 3/4" CONDUIT HUB

462

SSRB

Mariner™ Floodlight Remote Ballasted • Mounting accessories – Hot dipped galvanized steel • SFMH2 and SSRB Listings • UL844, CSA 22.2 No. 137-M1981: Class I, Div. 2 Groups A, B, C, D; Class I, Zone 2 Groups IIC, IIB, IIC • ExnR, AxnR Restricted Breathing • UL1598A Marine Outdoor • UL 1598 Wet Location • Type approval American Bureau of Shipping (ABS) • NEMA 4X, IP66/67

class i division 2

• For use in corrosive, hosedown, marine, shipboard and hazardous environments • SSRB luminaire available in two styles; UH for asymmetric and HH (1000w MH only) for symmetric distribution • Restricted Breathing option for lower T-Ratings • Elevated ambient capability up to 65°C • Luminaire and ballast housing, lens frame, quick release lens latches – 16 gauge 316SS • Mounting yoke, safety lens door chains, cord grip, conduit hubs – 316SS Ordering Information

ssrb series

entries

SSRB Stainless Flood Remote Box, Class I, Division 2 Marine, Class I, Division 2/Zone 2 Marine

C1 3/4" Conduit hub

      1       2

wattage 0350 350w PSMH only 0400 400w PSMH, HPS 1000 1000w PSMH, HPS

source

voltage

H Metal Halide (1000w only) S High Pressure Sodium P Pulse Start Metal Halide (lamp included)

5 480V 6 Tri-Tap® (120, 277, 347V – not available in 400w PS) 8 Quad Tap® (120, 208, 240, 277V) E 220/240V, 50 Hz P 220V, 60Hz (400,1000w MH only)

Not CSA or NEMA certified with “F” option To denote voltage, replace X with 1 - 120V; 2 - 208V; 3 - 240V; 4 - 277V; 5 - 480V; 6 - 347V

Accessories - Order Separately Catalog Number 4024C-M38 4040-M38 4090-M38 PTL11, 2 PTL81, 2 PTL51, 2 PSC1, 2 SFM-LR 1 2

OPTIONS F(X)

1,2

Fusing (specify voltage)

SFMM/SFM2 Integral Ballast Ambient Suitabilities & T-Ratings

Description Hot-dipped galvanized steel slipfitter for 2” pipe (2 3/8” OD tenon) - hardware included Hot-dipped galvanized steel wall/pole bracket - hardware included Hot-dipped galvanized cross arm fitting for horizontal trunnion 20.0" (508mm) hardware included 15.25" (387mm) Photocontrol - Twist-Lock® cell 120V 0.62" diameter ® (16mm) Photocontrol - Twist-Lock cell 120 - 277V Photocontrol - Twist-Lock® cell 480V Photocontrol shorting cap - Twist-Lock® mount (completes circuit) 1/8” diameter, 3’ steel safety cable, hot-dipped galvanized

Not UL 1598A Marine Outdoor listed Available in SFMM only; Not suitable for hazardous locations

Wattage and Lamp Type 150w PSMH 250w PSMH 400w PSMH 150w9.25" HPS (235mm) 250w HPS 11.25" (286mm) 400w HPS Note:

Supply wire rating is 90° 20.0" (508mm)

6.63" (168mm)

15.25" (387mm) 0.62" diameter (16mm)

9.25" (235mm)

6.0" (152mm)

11.25" (286mm)

T-Ratings & Ambient Temperatures 40°C 50°C 65°C Class I Class I Class I Class I Class I Class I Div. 2 Zone 2 Div. 2 Zone 2 Div. 2 Zone 2 / Zone ExnR / Zone ExnR / Zone ExnR 2 AExnR 2 AExnR 2 AExnR T1 T4 T1 T3 T1 T3 T1 T3 T1 T1 — — T1 T3 — — — — T2A/T2 T4 T2 T4 T2 T3 T1 T3 T1 T3 — — T1 T3 — — — —

For standard SFM2 (less suffix “EA”), apply T-Ratings from 40°C column above

SFMM/SFM2 Integral Ballast Supply Wire Ratings (Suffix “EA”) Wattage and Lamp Type 250w PSMH 400w PSMH 150w HPS 250w HPS 400w HPS

40°C 110°C 110°C 90°C 90°C 110°C

Ambient Temperature 55°C 110°C — 90°C 110°C —

65°C — — 110°C — —

1.5" (38mm)

Supply wire rating is 90° 6.63" (168mm)

463 6.0"