Line Voltage Regulation Line Volts Line Watts Frequency Circuit Type Power Factor (min)
FOR ONE 50 WATT, M110 MH
120/277 V
+/-5% +/-10% 60 Hz HX-HPF 90% A(105°)
Insulation Class Min. Ambient Starting Temp.
ISO-9000
-20º F or -30° C
Line Voltage (Volts) Line Current (Amps) Operating Open Circuit Starting Input Watts (W) Open Circuit Voltage (V) Drop Out Voltage (V) UL(1029) Bench Top Rise Recommended Fuse (Amps)
120
277
0.60
0.25
1.33 0.57 67
0.58 0.24 67
250 90 A 3
250 208 A 2
“B”
2.63”
3.19”
2”
“C” “A” 5/16”Slots
CASE DIMENSIONS Over-all Length Case Length Mounting dimensions
HIGH POTENTIAL TEST (VOLTS)
1Minute
2000
2 Seconds Open Circuit Voltage Test(volts)
2500 230-280
Short-Circuit Current Test (Amps) 0.16 0.23
0.36 0.50
Input Current (Amps)
11.75” 10.50” 11.13”
Sound Rating Lead Lengths (inches)
0.70-0.85
Secondary Current
“A” “B” “C”
B 12
PRODUCT LABEL Lamp Type
120V
50W M110
M50/120/277/F-CAN
CLASS 105 INSULATION SYSTEM
120/277 V 0.60/0.25 A 250 Voc 60Hz HX-HPF Autotransformer Máx. Input current without lamp 1.330 A
R
LISTED E-191673
SOUND RATED
47195-4
BALLAST
TYPE 1 Outdoor
Made in Mexico
277V
BLACK YELLOW
Do not install insulation within 3 inches of ballast sides or above ballast in such a manner to entrap heat Use 4KV pulse rated lampholder
WHITE
LAMP
Ground ballast case
WIRING DIAGRAM G
Thermally Protected Suitable for Recessed Use
RED
B
COM
277V
COM
BLACK YELLOW
BALLAST
Non PCB
G 03
120V
WHITE RED
CARTON LABEL 1B l l a s t Kit 1 aBallast
1 S K U ’s
M50/120/277/F-CAN
GROUND BALLAST CASE
M 11 0
R O
METALARC
120/277V
Magnetic Ballast / Ballast magnétique
120/277 VOLT CONNECTION
Mexico
47195-4 1
0 0
4 6 1 3 5
4 7 1 9 5
LAMP
IGNITOR: IN CAN The ignitor is included as part of the potted assembly. Maximum Distance to Lamp: 50 feet
4
Thermally Protected Suitable for Recessed Use Do not install insulation within 3 inches of ballast sides or above ballast in such a manner to entrap heat