Microdialysis Sampling

Report 1 Downloads 53 Views
High Temporal and Spatial Resolution Microdialysis to Identify Neurological Disease and CNS Efficacy Biomarkers Robert Kennedy, Woonghee Lee, Omar Mabrouk, Thomas Slaney, Non Thitaphat, Peng Song, Paige Malec Collaborators: George Rebec, Shelly Flagel, Huda Akil, Margaret Gnegy

Monitoring Neurotransmitters in the Living Brain

 Goal: Identify chemical signals in behavior, learning, pharmacology, pathophysiology

 Technical Challenge: Measure release and dynamics for all neurotransmitters in vivo at high spatial and temporal resolution

In Vivo Monitoring Methods PET

Some limits: $$$, immobilized

Implantable Sensors

Some limits: Few analytes, one at a time, no basal concentrations

Genetically Encoded Fluorescent Sensors •Peters, et al. (2002) Bioelectrochemistry 9: 461-482 •Okumoto S et al. PNAS 2005;102:8740-8745

Some limits: genetic, sensor development

Microdialysis for In Vivo Monitoring aCSF

Sample transfer tubing

Fractions Or On-line analysls

Pump

2.0

1.5

1.0

0.5

0

Microdialysis Probe

5

10

15

20

Microdialysis Sampling

aCSF 0.3 - 1 mL/min

Fractions Analyzed: HPLC, RIA, MS

-Highly Versatile but… -Typically only measure 1-2 compounds at a time -Low temporal resolution (10 min) because of assay requirements

1-3mm

(1 s = 16 nL sample)

-Low spatial resolution 200mm

Low Molecular Weight Neurotransmitters & Metabolites

Methods for Neurotransmitter Analysis 

  

LC-EC for dopamine, NE, 5-HT LC-Fluorescence for Amino acids Enzyme assay for Ach LC-MS?

Recent Progress in LC-MS Methods for Neurotransmitter Analysis

Polar neurotransmitters hard to retain Ion-pairing Hydrophilic Interaction LC (HILIC) is promising but LOD problematic

Ji et al., Anal. Chem. 2008, 80. 9195-9203 Zhang et al., Rapid Commun. Mass Spectrom. 2007, 21. 3621-3628

Benzoyl Chloride as Derivatization Reagent

Polar compounds retained Improves MS sensitivity Easy to quantify Reacts with many functional groups

Multicomponent Neurochemical Detection by 400 Benzoylation with LC-MS 350 300 250

%

GABA GluTh Gly Ser 200 Glu Hist Asp 150 Carn Gln Tau 100 ACh 50

HVA

Oct

NM 5HIAA

0 2 4 6 Time (min)

8

10

12

Epi DA

3MT DOPAC AMPH

Ado 0

LDOPA 5HT

NE

14

16

Dialysate Plasma 18 Tissue 20 22 24

Neurochemical Phentotyping by Microdialysis: Drug Abuse Vulnerability  bred High Responders (bHR) – – – – –

Increased cocaine self-administration Greater response to stressors Novelty seeking More aggressive “Impulsive”



bred Low Responders (bLR) – Less likely to self-administer – Avoid novelty – “Anxious”

Flagel et al., 2010 Neuropsychopharmacology

Neurochemical changes in response to cocaine

Norepinephrine differences 

Norepinephrine – Involved in stress and mood – Thought to be involved in ADHD and addiction – Recently shown to modulate cocaine induced dopamine release and hyperactivity in the nucleus accumbens Mitrano et al., 2011 Neuropsychopharm



Neurotransmitteromics uncovered norepinephrine as a possible major contributor to bHR and bLR behavioral traits

Amphetamine • 2nd most abused drug • Approximately 15% of 10th graders have used amphetamines without a prescription.

Effects of Amphetamine • Amphetamine: – euphoria – hyperactivity – tachycardia – appetite suppression – addiction and craving

• Increases extracellular dopamine • No current universally accepted chemical treatment for abuse.

Amphetamine

18

Amphetamine Promotes PKCb Activation & Enhances Outward DA Flux Through DAT

Amp

+

PKCβ

_

+ DAT

Gnegy M, Eur. J. Pharm. 2003, 479: 83

CCG215103

Inhibits Protein Kinase C (PKC) CNS Permeable

20

Subcutaneous Administration of 6 mg /kg CCG215103 Decreases AMPH Effects Locomotion

Effect on endogenous levels of neurochemicals

1-way RM ANOVA 22 p < 0.0001

Effect on endogenous levels of neurochemicals

1-way RM ANOVA

23 p < 0.0001

Extending the Method: 70 Compounds

Classification of 70 BzCl Labeled Metabolites Misc

Di/Tripeptides

Neurotransmitters

Polyamines Trace Amines

Amino Acid Metabolites

Neurotransmitter Metabolites

Amino Acids

Microdialysis for In Vivo Monitoring: Temporal Resolution Issues aCSF Pump

Microdialysis Probe

Sample transfer tubing

Fractions

Fraction volume will decrease with increasing temporal resolution

Analytical Challenge of High Temporal Resolution Sampling 4000

1.2x10 1.0

Sample Per h

3000 0.8

2500 2000

0.6

1500

0.4

1000 0.2

500

Higher Throughput

0

0.0 0

2 4 6 8 Temporal resolution (min)

10

Moles of analyte per sample

3500

-11

Use Segmented Flow to Collect Nanoliter Fractions from Dialysis Probes Sample

Immiscible Fluid (fluorinated oil/ gas)

On-Board Droplet Generator for Awake Animal Experiments with Reagent Addition Dialysis Probe

Droplet Generator

Coupling to Analysis On-line analysis

MS Enzyme CE

PDMS Headpiece aCSF 4 cm Volume ~2 nL

Off-line Analysis Collection Tubing

Pump

MS Enzyme CE

Microdialysis Interfaced to Segmented Flow ESI-MS

“MS-Based Sensor”

MS Sensing In Vivo: ACh Response

Recording Rapid Chemical Changes in the Brain

50 25 0

Aspartate (% of Basal)

0

200

400

600

800

1000

Aspartate 10 s

400

300B. K.; Pomerleau, F.; Burmeister, Day, J. J.; Huettl, P.; Gerhardt, G. A. J. 200 Neurochem. 2006, 96, 1626-1635. 100 0 0

200

400

600

Glutamate 500

10 s

400 300 200 100 0 0

800

1000

Taurine (% of Basal)

GABA mM)

10 s

Glutamate (% of Basal)

GABA

200

200

400

Taurine

600

800

1000

10 s

150 100 50 0 0

200

400

600

800

1000

Huntington’s Disease • “CAG Repeat” disease • Neurodegenerative • Cognitive and motor impairment • Death within 15 years • ~30k cases in USA • Little treatment available

Glutamate Neurotransmission Decrease of Glt-1 expression (glutamate toxicity?)

HD Mice Have Impaired Glu Uptake Measured by Microdialysis with Electrophoresis Percent Basal (Glu)

220

WT

160

100

40 80 s

HD

Drugs to Affect Glutamate Transporter

“beta-Lactam antibiotics offer neuroprotection by increasing glutamate transporter expression” by Rothstein JD, Patel S, Regan MR, et al. NATURE, 2005, 433: 73-77

ceftriaxone

Increase of Glt-1 with Ceftriaxone Treatment

Ceftriaxone Improves Motor Performance

Recovery of Normal Glu Uptake in HD Mice with Cef Percent Basal (Glu)

220

Control 160

HD (R6/2)

HD + Cef

S S S

100

40 80 s

Spatial Resolution Issues

mm

Ventral Tegmental Area (VTA)

Miniaturized Alternative to Microdialysis Sampling Microfabricated “Push-Pull” Sampling Probe

Improved Spatial Resolution

Pull

Push

1 mm

Microdialysis PushPull

50 mm 50 nL/min flow

Rat Brain “Atlas”

Microfabricated Probes

Channel ID: 19 µm

Inside channel view 50 mm

Evolution of Sampling Probes: Better Spatial Resolution Dialysis Mini Push-pull Microfab Push-pull

Tyrosine Hydroxylase is Localized

Red Nucleus

Ventral Tegmental Area

0.5 mm

Ikemoto, S. Neuroscience & Biobehavioral Reviews 2010, 35, 129-150.

Spatially Resolved Measurements in VTA/RN

Microinjection into the Brain to Evoke Local Changes in Neurochemistry Microinjector

2 mm Dialysis Probe

Push-pull

500

10 s

400 300 200 100 0

Taurine (% of Basal)

0

200

400

600

800

10 s

150 100 50

2 mm probe

0 0

200

400

600

800

Glutamate

1500

1000

10 s

1000 500 0 0

1000

Taurine

200

Glutamate (% of Basal)

Glutamate

Taurine (% of Basal)

Glutamate (% of Basal)

Effect of Probe Size on Measuring Local 2 mm Probe Changes 0.5 mm Probe

200

50 100 150 Relative Time (s) Taurine

10 s

100

0

Small probe

Less Invasive Sampling Track Dialysis Probe Track

mm

Photograph of Probe with Droplet Generator

R1

Push Oil

1 cm

R2

PDMS chip Pull Collection Tubing

Probe

Combining High Temporal and Spatial Resolution R2

R1

Plugs Oil

Vacuum

PDMS chip Holder

Inlet

500 µM Probe

Sample

In Vitro Sampling of Glutamate at 150 nL/min 120000

R² = 0.996

120000 13 µM 60000

9 µM

80000

0

RFU

0

5 10 [Glu], µM

15

6 µM

40000

4 µM 2 µM

0 220

270

320

• Rise time = 5 s

370 Time (s)

420

470

520

Microfabricated Dialysis Probe

Summary • LC-MS Method for 70 neurochemicals • Used to assess drug effects, disease states, and • •

behavior Microfabricated probes for better spatial resolution Droplet technology for high temporal resolution

Acknowledgements