Mini™ Sizing Guide

Flow Rate at Sink

Mini™ Sizing Guide Single Hand Washing Sink Tankless Electric Water Heater Flow

GPM

Ultra-Low

0.32

Standard

0.50

Standard

0.66

High

1.0

Mini 2-1* ™

MINI™ MODEL

Mini 2.5-1

Mini™ 3-1



120 V Min. recommended 15 A circuit breaker

120 V Min. recommended 20A circuit breaker

Mini™ 3.5-1

120 V Min. recommended 25 A circuit breaker

Mini™ 4-2

120 V Min. recommended 30 A circuit breaker

240 V Min. recommended 15 A circuit breaker

Mini™ 6-2

240 V Min. recommended 25 A circuit breaker

*Mini™ 2-1 is internally restricted to 0.32 GPM. Mini™ 2-1, 2.5-1, 3-1 ship with a 0.5 GPM pressure compensating flow reducer/aerator that must be installed. Mini™ 3.5-1, 4-2 ship with a 0.66 GPM pressure compensating flow reducer/aerator that must be installed. Mini™ 6-2 ships with a 1.0 GPM pressure compensating flow reducer/aerator that must be installed.

AK

BC AB

ON

MT

ME

ND

OR

MN

ID WY NV CA AZ

CO

NY

WI

SD

MI IA

NE UT

IL

KS OK

NM

IN

MO

PA OH KY

WV VA

SC

LA

AL

NS

VT NH MA RI CT

NJ DE MD

NC

TN AR MS

TX

NB

QC

MB

WA

Cool (Northern) Climate Inlet water 45°F - 55°F

PE

SK

GA

Warm (Southern) Climate Inlet water 55°F - 70°F

HI

Recommendations for 240 V models are correct if installed with 240 V service. Increase one model size if unit will be installed with 208 V service. Call Stiebel Eltron at 800.582.8423 if you have any sizing questions, or if you have any out-of-the-ordinary situations. Stiebel Eltron service representatives can make recommendations on sizing, or provide assistance with our water heaters, to both homeowners and professional installers.

Scroll for temp rise charts. 

17 West St., W. Hatfield, MA 01088 | 800.582.8423 | 413.247.3380 | fax 413.247.3369 | [email protected] | www.stiebel-eltron-usa.com

Mini™ Sizing Guide Temperature Rise vs. Flow Rate 90 80 Mini™ 2-1, 2.5-1, 3-1, 3.5-1 @ 120 V

70

Mini™ 4-2, 6-2 @ 240 V & 208 V

Temp Rise °F

60 50 40

Mini™ 2-1 0.32

0.5

0.77 0.66

30 20

Mini™ 6-2 Mini™ 4-2 Mini™ 3.5-1 Mini™ 3-1 Mini™ 2.5-1

10 0

0.25

0.5

0.75

1.0

1.25

1.5

1.75

2.0

Flow Rate GPM

Temperature Rise vs. Flow Rate @ 208 V 90 80 Mini™ 4-2, 6-2 @ 208 V

70

Temp Rise °F

60 50 40

0.77 0.66

30 20

Mini™ 6-2 Mini™ 4-2

10 0

0.25

0.5

0.75

1.0

1.25

1.5

1.75

2.0

Flow Rate GPM