Mixed Cellulose Ester Membranes

Report 24 Downloads 128 Views
Particulate Sampling Filters

Mixed Cellulose Ester Membranes A Gold Standard for IH Sampling

ABOUT MCE Filters and Nanoparticles NIOSH has been using the SKC Leland Legacy Sample Pump (pages 22-23) with 0.8-μm MCE filters for exposure assessments of engineered nanoparticles. After collection onto 37-mm MCE filters in open-face cassettes, particles are analyzed for particle morphology and elemental mass. Note that nanoparticles will not fall through the pores of the 0.8-μm MCE filters; the very intense activity of nanoparticles and their constant collision with other particles prevent them from going through the pores like a sieve. For more information, see NIOSH Publication No. 2009125, Approaches to Safe Nanotechnology: Managing the Health and Safety Concerns Associated with Engineered Nanomaterials at www.cdc.gov/niosh/docs/2009125/, download the PDF, and scroll to the Appendix on page 71, which contains the sampling information.

The standard filter for most particulate sampling in industrial hygiene applications, mixed cellulose ester (MCE or MEC) membrane filters are comprised of pure, biologically inert mixtures of cellulose acetate and cellulose nitrate. MCE membranes are naturally low in metal background and are compatible with dilute bases and acids and aromatic and aliphatic hydrocarbons. MCE filters are hydrophilic and autoclavable.

MCE Filters Diameter (mm) 25 25 25 25 25 25 37 37 37 37 37 37 37 47 47 47 102

Pore Size (μm) 0.45 0.8 0.8 0.8 1.2 1.2 0.45 0.45 0.8 0.8 0.8 1.2 5.0 0.45 0.8 1.2 0.8

Support Pad‡ No Yes No No No No No Yes No Yes No No No No No No No

† Recommended for use with the Button Sampler, see page 93

Notes

use with IOM (p. 92) black grid black grid

black grid

Cat. No. 225-1911 225-19 225-1930 225-1913 225-1912† 225-60F 225-1914 225-9 225-1939 225-5 225-334 225-1923 225-1938 225-506 225-504 225-1921 225-1916

Qty. 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 25

‡ Filter supports available on page 87

ACCU-CAP MCE Filter Cassette Inserts

ACCU-CAP Inserts Air with Contaminants Enters Here ACCU-CAP Cassette Insert

Cassette Inlet Section Fibers and Particles

Cellulose Pad

Cassette Outlet Section

ACCU-CAPs are clear static-dissipative PVC or dissolvable cellulose acetate domes heat-sealed to a filter to create a filter capsule. ACCU-CAPs fit between the parts of a two-piece cassette with support pad. Containment of the sample within the capsule prevents cassette wall losses. Use the PVC dome for gravimetric analysis; use the cellulose acetate dome for elemental analysis. ACCU-CAPS are designed to work with SKC cassettes.

Diameter (mm) 25 37 37

Pore Size (μm) 0.8 0.8 0.8

Dome Material static-dissipative PVC static-dissipative PVC dissolvable cellulose acetate

Notes

Preloaded in 2-pc cassette with support

Cat. No. 225-8506 225-8514 225-8517

Qty. 60 60 50

Matched-weight MCE Filters for Faster Gravimetric Determinations

Matched-weight MCE filter pairs are certified as matched in weight to within 50 μg. Load the filters into a cassette; the top filter collects the contaminant, the bottom filter acts as a control. No preweighing or conditioning is required. After sampling, both filters are weighed and the difference between weights is the sample weight.

Diameter (mm) 37 47

Filter Specifications MCE, 0.8 μm, matched-weight within 50 μg, filter pairs only* MCE, 0.8 μm, matched-weight within 50 μg, filter pairs only*

Cat. No. 225-532* 225-531*

Qty. 50 50

* Not preloaded in cassettes

76

www.skcltd.com

SKC Ltd.

Phone: +44 (0)1258 480188

Particulate Sampling Filters

Certified BestChek Asbestos Cassettes The Highest Standard for Cassette Reliability

ABOUT

SKC Certified BestChek Filters in Carbon-filled Polypropylene Cassettes All SKC preloaded asbestos filters include cellulose supports.

Diameter (mm) Filter Specifications 25 MCE, 0.8 μm

Cassette Description with cowl, banded

Cat. No. 225-321

Qty. 50

225-321A

50

225-326

50

25

MCE, 0.8 μm

25

MCE, 0.8 μm, black grid

with cowl, banded, with stand-up plug in outlet end with cowl, banded

25

MCE, 1.2 μm, black grid

with cowl, banded

225-1934

50

25

MCE, 0.45 μm* TEM analysis

with cowl, banded, with support and 5.0-μm diffuser pad

225-327

50

The 5 C’s of Asbestos Cassettes Only from SKC — BestChek® cassettes meet or exceed NIOSH, OSHA, and ASTM standards in Count, Clearing, Conductivity, Collection Area, and Construction.

Specify SKC BestChek Asbestos Cassettes — your assurance of reliability and accuracy.

* Available as microvacuum carpet cassette with nozzle, see far right

Preloaded MCE Filters Preloaded MCE Filters

All SKC preloaded filters include supports and are in SureSeal leak-free cassettes requiring a SureSeal Cassette Opener (see p. 88).

Diameter (mm) 25 25 37 37 37 37

Filter Specifications MCE, 0.8 μm MCE, 1.2 μm MCE, 0.45 μm MCE, 0.45 μm MCE, 0.8 μm MCE, 0.8 μm

Cassette Description 3-pc clear plastic, banded 3-pc black conductive, banded 3-pc black conductive, banded 4-pc clear styrene, banded 2-pc clear styrene, banded 3-pc clear styrene, banded 3-pc clear styrene, banded 3-pc clear styrene, not banded

Cat. No. 225-3100 225-507 225-1924 225-1925 225-508 225-3-01 225-3-01A 225-3-01NB

Qty. 50 50 50 50 50 50 500 50

Matched-weight MCE Filter Cassettes

All SKC preloaded filters include supports and are in SureSeal leak-free cassettes requiring a SureSeal Cassette Opener (see p. 88).

Diameter (mm) 25 37 37

Filter Specifications MCE, 0.8 μm, matched-weight within 50 μg MCE, 0.8 μm, matched-weight within 100 μg MCE, 0.8 μm, matched-weight within 50 μg

37

MCE, 0.8 μm, matched-weight within 50 μg

Cassette Description 2-pc clear styrene, banded 3-pc clear styrene, banded 2-pc clear styrene, banded

Cat. No. 225-525 225-3-02 225-502 225-527 3-pc clear styrene, banded 225-503 225-528

Qty. 50 50 50 12 50 12

Microvacuum Cassettes for Asbestos • Nozzle for easy sampling of settled dust on surfaces • Meets specifications of ASTM D5755 and D5756 • Use with a high flow pump

Carbon-filled polypropylene with cowl and nozzle. 25-mm 0.45-μm MCE filter, BestChek, for TEM analysis Cat. No. ................................225-322 Styrene (non-conductive) with nozzle. 37-mm 0.45-μm MCE filter, for TEM analysis Cat. No. ..............................225-9543

Nano-Neat MCE Filter Cassettes

Ultra-pure for sampling workplace chromium. Cassettes are tinted purple for easy identification. Each box contains a Certificate of Conformance. All SKC preloaded filters include supports and are in SureSeal leak-free cassettes requiring a SureSeal Cassette Opener (see p. 88).

Diameter (mm) 25 25 37 37

SKC Inc.

Filter Specifications MCE, 0.8 μm, Nano-Neat MCE, 0.8 μm, Nano-Neat MCE, 0.8 μm, Nano-Neat MCE, 0.8 μm, Nano-Neat

Phone: +1-724-941-9701

Cassette Description 2-pc purple styrene, banded 3-pc purple styrene, banded 2-pc purple styrene, banded 3-pc purple styrene, banded

Cat. No. 225-8402 225-8404 225-8408 225-8410

Qty. 50 50 50 50

www.skcinc.com

For asbestos sampling pump and accessories see pages 26-27 77