THE BUILDING BLOCKS FOR LUXURY OUTDOOR SPACES.
48"
15"
21"
Model OLPLSFP04 Outdoor Fireplace 66"
9"
INSTALLATION / OPERATION INSTRUCTIONS 6" 82"
40" 13"
48"
13"
21" 30"
66"
15"
36"
24"
9" 6" 82"
40"
33"
13"
33"
PART NUMBER
DESCRIPTION
OLPLSFP04-1
ILLUSTRATION
13"
30"
36"
33"
16"
33"
24"16"
39"
39"
PART NUMBER
DESCRIPTION
Left Side Hearth
OLPLSFP04-B
Left Side Firebox Insert Panel
OLPLSFP04-2
Right Side Hearth
OLPLSFP04-C
Rear Firebox Insert Panel
OLPLSFP04-3
Left Side Column
OLPLSFP04-21
Metal Flue Liner Bottom Section
OLPLSFP04-4
Right Side Column
OLPLSFP04-22
Metal Flue Liner Top Section with Spark Arrester
OLPLSFP04-5
Mantel Section
OLPLSFP06
Hearth Extension
OLPLSFP04-6
Chimney Section
OLPW81633
Hearth Extension Backrest
OLPLSFP04-7
Back Panel
OLPLSFP05
Chimney Extension with Metal Flue Liner
OLPLSFP04-8
Front Plate
OLPLSFP04-A
Right Side Firebox Insert Panel
ILLUSTRATION
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
WARNINGS
Obtain necessary permits from authorities in local jurisdiction and comply with all local building codes.
To avoid the risk of damaging fireplace materials & increasing risk of spreading fire, do not use the fireplace to cook or warm foods.
This unit has not been tested for use with doors. To reduce the risk of injury, do not install doors.
When burning wood, you must use a fireplace screen to minimize the winds effect on hot embers.
Do not burn large amounts of paper, cardboard, tree branches or building construction materials. The intense fires these products create may overheat the fireplace thus causing damage to the unit or a potential fire outside the firebox.
Do not over burn.
This product has not been tested for use with a chase. To reduce the risk of fire, do not install a chase.
Do not pack air spaces with insulation or other materials.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 2 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
PRODUCT USAGE The OLPLSFP04 is designed to burn solid woods or gas outdoors. This unit is not designed to sit directly against combustible materials. This unit is not designed to be built into a wood structure. The Eldorado Outdoor model number OLPLSFP04 is designed as an outdoor unit only. The OLPLSFP04 is shipped with the appropriate flue liner and has been tested to comply with UL-127/ ULC-S610. Use solid wood, plumbed propane or natural gas fuel only. Gas log appliances used with this product must be approved for outdoor use.
MODIFICATION OF FIREPLACE The addition of extensions may be accomplished by using the Eldorado Outdoor extensions (shown on the first page), metal framing or concrete block. There is no clearance or airspace required when using extensions, metal framing or concrete block.
CHIMNEY EXTENSIONS The standard height of 6 ft. 8 in. is the height tested to achieve proper draft characteristics. If conditions exist that require additional chimney height, please follow all local building codes and regulations during installation. The addition of the concrete extension OLPLSFP05 requires an additional flue liner which is included in OLPLSFP05. A maximum of two OLPLSFP05 Chimney Extensions can be used on top of the OLPLSFP04 Chimney Section. If a prefabricated metal chimney is chosen, it must be tested and found compliant with UL-103. It must be installed in accordance with chimney manufacturer’s instructions and use all necessary parts specified for use with the listed chimney system. Chimney termination must be a minimum of 2 ft. above any combustible structure within 10 ft. of the chimney termination.
INSULATION This product is not designed to be “packed” by insulation. In the event air spaces exist between this product and CMU or metal framing construction, do NOT fill these voids with an insulating product.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 3 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
PRODUCT USAGE VENTILATION The OLPLSFP04 is designed as an outdoor unit only. No additional ventilation or circulation is required. 10" Mantel Fireplace Profile
" 12
Firebox
MANTEL CLEARANCES A decorative mantel may be installed above the opening of a Model OLPLSFP04 Fireplace providing the front edge of the mantel is no more than 10 in. from the face of the fireplace and a minimum of 12 in. above the opening.
CLEARANCES The distances to combustibles while burning solid wood shall be no less than 60 in. from the front of firebox, 12 in. from the side walls and 4 in. from the back wall. When a UL approved 40,000 BTU vent-free gas log set is used and the top of the chimney capped, the clearances shall be no less than 16 in. from the front, 4 in. from the back and 1 in. from the top of the chimney.
DAMAGED PARTS If unit is delivered with obvious damage due to freight, please notify driver or refuse delivery. If product is damaged on job site, you may be able to repair unit using adhesive and/or mortar. If damage is severe, contact your dealer to arrange shipment of replacement parts.
MAINTENANCE Please contact a professional chimney sweep at least once each year to inspect and make recommendations regarding the maintenance of your outdoor fireplace. In the event you have added a decorative chimney termination or rain cap to your fireplace, please be prepared to inform the chimney sweep as to the best method to perform proper inspection/maintenance.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 4 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION GUIDELINES First make sure your installation surface is clean and stable. If needed, use shims to level the fireplace during installation. The unit can be placed on a 4 in. concrete slab or a paver patio that has been installed following ICPI (Interlocking Concrete Paver Institute) guidelines.
STEP 1: HEARTH ( L/R ) A) B) C)
D) E)
Place the Hearth sections next to each other in their final installation location. Lift the Hearth sections onto the front edges to access them from underneath. Apply construction adhesive between the Hearth sections and push them together, being sure to line up the bolt holes. Insert 4 bolts with 8 washers and 4 nuts. Tighten a ¼ turn past snug. Lay the Hearth down and slide into position. Use shims if necessary to level the Hearth
STEP 2: HEARTH EXTENSIONS (IF APPLICABLE) A)
B) C)
D) E)
Place a Hearth Extension next to the assembled Hearth. Make sure the 4 bolt holes on top of the Hearth Extension are at the back of the Hearth. Apply construction adhesive to the Hearth Extension side wall and adhere to the Hearth. Using the access holes in the Hearth and the Hearth Extension, insert 4 bolts with 8 washers and 4 nuts. Tighten a ¼ turn past snug. Repeat on the other side if using two Hearth Extensions. Use shims to level the completed Hearth, if necessary.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 5 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION GUIDELINES
STEP 3: COLUMNS / LEGS ( L/R ) A) B) C)
D)
Apply construction adhesive around the access hole on top of the Hearth section where the column will sit. Place the column over the access hole with the open side facing inward, being sure to line up the bolt holes. Reaching through the column and into the Hearth base, insert 4 bolts with 8 washers and 4 nuts. Tighten a ¼ turn past snug. Repeat on the opposite side.
STEP 4: BACK PANEL (EXTERIOR) A) B) C) D)
E)
Insert Back Panel between two side Columns/Legs. Apply construction adhesive where the pieces connect and line up using bolt holes. Use four 6” bolts included. Insert 4 bolts with 8 washers and 4 nuts. Be sure the bolts extend into the column leaving the Back Panel open to accept the Rear Refractory Panel in step 6. Tighten bolts a ¼ turn past snug.
STEP 5: HEARTH BACKREST EXTENSIONS (IF APPLICABLE) A)
B) C) D) E)
Apply construction adhesive to the top of the Hearth Extension where the Hearth Backrest Extension will be placed. The open side of the backrest should face upward when installed. Place Backrest Extension on top of Hearth Extension and line up bolt holes. Insert 4 bolts, 8 washers and 4 nuts through the holes at the bottom of the backrest section. Reach through the Hearth Extension access holes to tighten nuts ¼ turn past snug. Apply adhesive to the beveled edge of the lid provided and set in place to close off the top of the unit.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 6 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION GUIDELINES
STEP 6: REAR REFRACTORY PANEL A)
B)
Tack the panel in place by applying construction adhesive to the backside (corners only) of the Rear Refractory Panel. Insert panel through fireplace opening with scratch coat facing out. Place foot of Refractory Panel on top of the Back Panel footing. The Rear Refractory Panel fits inside the Back Panel.
STEP 7: MANTEL SECTION A)
B)
C)
D)
Apply construction adhesive to the top of the Legs and the Back Panel (exterior). i) Do not apply adhesive along the top of the Rear Refractory Panel. It should remain clean to accept the Metal Flue Liner Bottom Section in step 9. Place the Mantel Section on top of the unit lining up the bolt holes. The smaller opening should be up and at the back of the fireplace unit. Insert 8 bolts, 16 washers, and 8 nuts in the holes at the top of the Legs. Access these bolt holes through the firebox and the open Legs. Tighten bolts a ¼ turn past snug.
STEP 8: FRONT PLATE A) B) C) D)
Apply construction adhesive to the top of the Front Plate (side with bolt holes). Install Front Plate between the Legs and against the bottom of the Mantel Section. Line up bolt holes and add 3 bolts, 6 washers, and 3 nuts by accessing from inside the fireplace opening. Tighten a ¼ turn past snug.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 7 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION GUIDELINES STEP 9: METAL FLUE LINER – BOTTOM SECTION A)
B) C)
D) E)
Make sure the Rear Refractory Panel is adhered, or supported. This flue section will rest on top of the Rear Refractory Panel and the Side Firebox inserts. The Side Firebox inserts install in Step 10. Remove the provided sheet metal screws from the front of the Flue Liner before installing. Go through the fireplace opening with the long back flange facing up and inward (the front of the flue has no flange). Use the openings in the Legs to maneuver the flue through the fireplace opening. Rest the back flange of the Flue Liner on the top of the Rear Refractory Panel Push the Flue Liner up and hold in place while another person completes Step 10.
STEP 10: SIDE FIREBOX INSERT PANELS (2) A) B) C) D)
Place the foot of the Side Insert Panel at the base of the Leg opening. Tack the panel in place by applying construction adhesive to the backside (corners only). Press the Side Firebox Insert Panel into place. Repeat on the opposite side.
STEP 11: CHIMNEY SECTION A)
B) C) D)
Center the Metal Flue Liner Bottom Section (installed in Step 9) within the Mantel Section opening on the top of the fireplace. Add adhesive to the top of the Mantel Section where the Chimney Section will be placed. Lift Chimney Section into place and line up bolt holes. Add 4 bolts, 8 washers and 4 nuts and then tighten a ¼ turn past snug.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 8 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION GUIDELINES STEP 12: CHIMNEY EXTENSION (IF APPLICABLE) A)
B)
Chimney Extension i) Add adhesive to the top of the Chimney Section where the Chimney Extension will be placed. ii) Lift the Chimney Extension into place and line up bolt holes. iii) Add 4 bolts, 8 washers and 4 nuts and then tighten a ¼ turn past snug. Metal Flue Liner Extension i) When adding a Flue Liner extension, connect the two Metal Flue Liners together as described below. ii) Place the Metal Flue Liner Extension (the one without the spark arrester) on the bottom and the regular Metal Flue Liner Top Section (with spark arrester) on top. iii) Use the 4 sheet metal screws provided to attach the two sections together from the inside.
STEP 13: METAL FLUE LINER – TOP SECTION(S) A)
B)
Insert Flue Liner Top Section (with the spark arrester at the top) through the top opening of the Chimney Section. If using a Chimney Extension, this will be two Flue Liners connected as one with the spark arrester on the top section. Enter through the fireplace and connect the Flue Liner Top Section to the Flue Liner Bottom Section using (4) sheet metal screws provided.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 9 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
INSTALLATION GUIDELINES STEP 14: FIRE BRICK (NOT PROVIDED) A) B) C) D)
Line the fireplace base and firebox with fire brick. We recommend full dimension fire brick on the bottom and split fire brick on the sides and rear wall. Fire brick on the bottom should be dry set to allow for drainage. Rough Dimensions for Fire Brick: Hearth Base = 5.75 SF Back and Side Walls = 20 SF (depending on height of your Hearth base material)
STEP 15: EXTERIOR FINISH (NOT PROVIDED) A)
Finish exterior of the Eldorado Outdoor Wood Burning Fireplace with Eldorado Stone, Eldorado Brick, natural veneer or stucco.
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 10 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
OPERATING INSTRUCTIONS This part of the manual covers methods to maximize the performance of your Eldorado Outdoor fireplace. If you are having trouble with your Eldorado Outdoor unit, please contact your installer or call 1-800-925-1491 for assistance. Use a log grate to place under the fuel when using solid wood fuels. We recommend using hardwood dried 6 to 12 months for best results. Place wood in firebox with ample air space between logs.
BUILDING A FIRE Start by placing some kindling in the center of your fireplace grate (see callout “A” in illustration below). Then lay one split section of log across each side of the kindling (“B”), placing the pieces of wood so that the ends nearer to the back of the fireplace (“C”) are closer together than the ends at the front. The wood should not extend more than an inch beyond the front of the grate or it may cause smoke to move out the front of the unit. Now lay an additional one or two pieces of wood across the two side logs (“D”). Push these top logs all the way to the back (“E”) so the rearmost lies against the rear wall of the fireplace. (E) P ush wood to touch rear interior wall
(D) Additional Wood
(C) (B) Split Logs
(C) M ove ends in back closer together
(A) Kindling
www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 11 of 12
Model OLPLSFP04 Outdoor Fireplace
INSTALLATION / OPERATION INSTRUCTIONS
OPERATING INSTRUCTIONS DISPOSAL OF ASHES •K eep the base of the fireplace clean of excess ash accumulation. This will prevent grate “burn-out.” •K eep the area directly underneath the burning logs free of ash. Make sure ash does not build up to a point where it hinders the air flow. •B efore removal, make sure the fire is completely out and the ashes cool. •U se a small fireplace shovel to remove accumulated ash. • Place the ashes in a metal container with tight-fitting lid and store the closed container on a non-combustible floor surface. Keep it well away from all combustible materials until final disposal. Dispose of the ash by burying it in soil or other local dispersal. Make sure ash is retained in the closed container until cinders have thoroughly cooled. •R eplace any grate that has deteriorated, distorted or sagged from extended use.
Eldorado Stone® LLC, 1370 Grand Ave. B, San Marcos, CA 92078 110711 www.eldoradostone.com/outdoor
|
1.800.925.1491
Page 12 of 12