MS6 WALL MOUNT

Report 18 Downloads 131 Views
MS6 WALL MOUNT 1, 2, 3, 4-Lamp, T5, T5HO, T8, Direct/Indirect Distribution Project Information Project Name

Type

Catalog No.

Date

Construction —All fasteners are concealed and maintained with a minimum amount of tolerance to ensure that fixture integrity is maintained. —Inner endplates are welded to housing to reinforce the rigidity of the unit.

Features • • • • • • • • •

Direct/Indirect Beam T8, T5, or T5HO Heavy duty 20-gauge steel construction Controls compatible Separate up/down lamp compartments create an efficient and creative optical system Different lamp and distribution options provide flexibility for any application Multiple shielding options provide a wide array of glare control levels All steel housing is sturdy yet economical Excellent for office, retail and hallway applications

—End caps are die formed 20 gauge steel and are installed in the field. —Individual lamp compartments for optimal light utilization and distribution.

Finish Standard housing finish is powder coat matte white. Other powder coat finishes are available as an option. Please see the Options section of this binder for more details. End caps and connectors are finished the same as the housing on all painted parts. Shielding The MS6 is available with a parabolic louver, acrylic lens, or a white straight blade baffle.

7¾"

Name: Test #: Efficiency: LER:

MS6-1U1DT8-LD-E 10976 68.5% 63

—The white straight blade baffle (WCB) is constructed of steel and finished with a gloss white finish and also is a lay-in type.

Ordering Information

Example: MS6-20-2U1DT8-WM-LD-EU-MW





LAMP PROFILE and DISTRIBUTION Lamp Type 1U1D 1-Lamp Uplight, T5 T52 1-Lamp Downlight1 T5HO T5HO2 1U2D 1-Lamp Uplight, T8 T8 2-Lamp Downlight1 Row Length 2U1D 2-Lamp Uplight, 4 4' Single 1-Lamp Downlight 8 8' Single 2U2D 2-Lamp Uplight, MOUNTING Method — Indicate row 2-Lamp Downlight WM Wall Mount, length over 8' in 1U1AD 1-Lamp Uplight, 1-Lamp Symmetric 4' increments Asymmetric Downlight1 Dist. Note: Rows 2U1AD 2-Lamp Uplight, 1-Lamp WMW Wall Mount, over 8' will be Asymmetric Downlight Wall Wash3 configured by Alera. Example: 16' will 1AU1D 1-Lamp Asymmetric WMR Wall Mount, be (2) 8'. Alternate Uplight, 1-Lamp Room Wash3 configurations: Downlight See HGR-1 for other contact factory. 1AU2D 1-Lamp Asymmetric hanging methods. Uplight, 2-Lamp Downlight 1AU1AD 1-Lamp Asymmetric Uplight, 1-Lamp Asymmetric Downlight



— Shielding LD Low Iridescent Semi-Specular Louver LS Low Iridescent Specular Louver A12 Acrylic Pattern 12 Lens A19 Acrylic Pattern 19 Lens CA Clear Acrylic Lens (No pattern) OA Opal Acrylic Lens (No pattern) WCB White Cross Baffle NA No Shielding

Connector box required on all 1-lamp connector uplight units if pendant or cable mounted. This option does not permit continuous shielding for all 1-lamp symmetric uplights. 2 T5/T5HO at risk for socket shadow in downlight component. 3 For use with asymmetric distributions. 4 LR requires 2 lamps in cross section. UB assumes 1 circuit up, 1 circuit down. Page 1/3 Rev. 06/14/13 1

Quick connect plugs standard.

—A variety of lenses are available and are lay-in type.

6"

Model MS6 MS6

Labels and Electrical All luminaires are built to UL1598 standards and bear the appropriate cUL or CSA labels. Damp location listed.

—Parabolic louvers are constructed of anodized aluminum with either a specular or semispecular finished. They lift and shift for easy lamp access.

Shape and Dimensions

MS6 —

Mounting The MS6 is designed for maximum versatility. Wall brackets are used for wall mounting unless wall-to-wall placement is desired. End caps are field installed so shielding will be continuous in row application. Aligner brackets are provided When patterns or rows are being used it is recommended that the factory be provided with a layout diagram.

— Voltage U 120V277V 120 120V 277 277V 347 347V

— Finish MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.

Ballast E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ED Electronic, Dimming (Must specify) ESD Electronic, Step Dimming Unless specified, Alera will use fewest ballasts possible.

Options DC Dust Cover (T8 or T5 only) LR Left/Right Switching4 UB Upper/Lower Switching4 EL One Emergency Battery Pack5, 6 EMC One Emergency Circuit 6, 7 NLC Night Light Circuit6, 7 GLR Fast Blow Fuse GMF Slow Blow Fuse TBAR T-Bar Mounting

Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). 6 Not available with all configurations; some limitations apply. Contact factory for details. 7 One extra feed drop per EMC/NLC. For through wiring, contact factory. 5

© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Beams / MS6 WM

MS6 WALL MOUNT 1, 2, 3, 4-Lamp, T5, T5HO, T8, Direct/Indirect Distribution Cross section 6"

7¾"

1-L Uplight, 1-L Downlight, Parabolic 1U1D

1-L Uplight, 2-L Downlight, White Cross Baffle 1U2D

2-L Uplight, 1-L Downlight, Lens 2U1D

2-L Uplight, 2-L Downlight, Parabolic 2U2D

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

MS6-2U1ADT8-WCB-3E MS6 Architectural Beam 6 × 48 WITH 2-LAMPS UP OPEN TOP AND 1-LAMP DOWN WHITE LVR ASY B332I120RH 0.93 FO32/741 2900 86 0º = 90  90º = 90 0º = N/A  90º = N/A Length: 3.96 Width: 0.40 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

90.0 135.0 180.0 225.0 270.0 5701 6215 5473 4901 4186 3341 1155 450 318 236 196 156

5701 6081 6130 5526 4504 3305 1971 740 397 315 274 156

5701 5956 5269 4392 3531 2820 1631 547 318 210 157 156

5701 6324 6343 5776 4493 3258 1903 740 397 315 274 156

5701 6215 5456 4949 4208 3388 1237 466 318 263 196 156

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 689 1148 1795 1865 1041 1820 3435 4611 6476

7.9 13.2 20.6 21.4 12.0 20.9 39.5 53.0 74.4

10.6 17.7 27.7 28.8 16.1 28.1 53.0 71.2 100.0

RCR

Luminaire

Angle

Luminaire Data Test 10990

RC RW 1 2 3 4 5 6 7 8 9 10

70 70 64 59 54 49 45 42 39 36 34

80 50 30 67 64 59 55 52 47 46 41 41 36 37 32 33 28 30 25 28 22 25 20

10 62 52 43 37 32 28 24 21 19 17

70 63 57 52 48 44 41 38 35 32 30

70 50 30 60 58 53 50 47 43 42 37 38 33 34 29 30 26 28 23 25 21 23 19

10 56 47 40 34 29 25 22 20 17 16

50 47 42 38 34 30 27 25 22 20 19

50 30 46 40 35 30 27 24 21 19 17 15

10 45 38 32 28 24 21 19 16 15 13

Indoor Candela Plot 0 0 19 17 15 13 12 10 9 8 8 7

135

150

165

180

165

150

135

1500

120

120 750

105

105

90

90

75

75 750

60

60

1500 45

30

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

15

0

270.0-90.0

15

30

45

180.0-0.0

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

74.4% 70 Yes-VDT Intensive Use $3.43 based on 3000 hrs. and $0.08 per KWH

Test Date 10/28/94

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

MS6-1AU1DT8-A12-E MS6 Architectural Beam 6 × 48 WITH 1-LAMP UP OPEN TOP ASY AND 1-LAMP DOWN A-12 LENS B232I120RH 0.95 FO32/741 2900 60 0º = 90  90º = 90 0º = N/A  90º = N/A Length: 3.96 Width: 0.40 Height: 0.65

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

90.0 135.0 180.0 225.0 270.0

5402 2206 1407 1124 878 674 506 376 291 227 157 68

5402 3043 2100 1692 1346 1034 755 525 378 297 234 110

5402 5402 5402 5730 18017 69193 5525 0 0 5243 0 0 4823 0 0 4333 0 0 3817 0 0 3424 0 0 3330 0 0 4406 0 0 27215 0 0 0 0 0

Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 603 936 1424 1629 583 1004 1837 2423 4053

10.4 16.1 24.6 28.1 10.1 17.3 31.7 41.8 69.9

14.9 23.1 35.1 40.2 14.4 24.8 45.3 59.8 100.0

RCR

Luminaire

Angle

Luminaire Data Test 10992

RC RW 1 2 3 4 5 6 7 8 9 10

70 61 56 52 47 44 40 37 35 32 30

80 50 30 59 57 52 48 46 42 41 36 37 32 33 28 30 25 27 23 25 20 23 18

10 54 45 38 33 28 25 22 19 17 16

70 56 51 47 43 40 37 34 32 29 28

70 50 30 53 52 47 44 42 38 37 33 34 29 30 26 28 23 25 21 23 19 21 17

10 50 42 35 30 26 23 20 18 16 15

50 43 39 34 31 28 25 23 21 19 18

50 30 42 36 32 28 25 22 20 18 16 15

10 41 35 30 26 22 20 17 16 14 13

Indoor Candela Plot 0 0 21 18 16 14 13 11 10 9 9 8

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

135

150

165

180

165

150

135

800

120

120 400

105

105

90

90

75

75 400

60

60

800 45

30

15

270.0-90.0

0

15

30

45

180.0-0.0

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

69.9% 64 Yes-VDT Intensive Use $3.75 based on 3000 hrs. and $0.08 per KWH

Page 2/3 Rev. 06/14/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Test Date 10/28/94 Beams / MS6 WM

MS6 WALL MOUNT 1, 2, 3, 4-Lamp, T5, T5HO, T8, Direct/Indirect Distribution Cross section 6"

7¾"

1-L Uplight, 1-L Asym. Downlight, Lens 1U1AD

2-L Uplight, 1-L Asym. Downlight, Parabolic 2U1AD

1-L Asym. Uplight, 2-L Downlight, Lens 1AU2D

1-L Asym. Uplight, 1-L Downlight, White Cross Baffle 1AU1D

1-L Asym. Uplight, 1-L Asym. Downlight, Parabolic 1AU1AD

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

MS6-1AU1DT8-WCB-E MS6 Architectural Beam 6 × 48 WITH 1-LAMP UP OPEN TOP ASY AND 1-LAMP DOWN WHITE LVR B232I120RH 0.95 FO32/741 2900 60 Pendant 0º = 45  90º = 47 0º = N/A  90º = N/A Length: 3.96 Width: 0.40 Height: 0.65

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

90.0 135.0 180.0 225.0 270.0 5708 2737 1561 1161 990 831 702 581 422 264 130 44

5708 2777 1849 1385 1024 795 643 510 388 276 165 67

5708 5708 5708 4074 16446 85825 3055 0 0 2564 0 0 2418 0 0 2337 0 0 2298 0 0 2357 0 0 2570 0 0 3321 0 0 16442 0 0 0 0 0

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 587 882 1267 1452 583 1004 1837 2423 3875

10.1 15.2 21.8 25.0 10.0 17.3 31.7 41.8 66.8

15.1 22.8 32.7 37.5 15.0 25.9 47.4 62.5 100.0

RCR

Luminaire

Angle

Luminaire Data Test 10993

RC RW 1 2 3 4 5 6 7 8 9 10

70 64 58 54 49 45 42 39 36 34 31

80 50 30 61 59 54 50 48 43 43 38 38 33 34 29 31 26 28 23 26 21 24 19

10 57 47 40 34 29 26 23 20 18 16

70 58 53 49 45 41 38 35 33 31 29

70 50 30 56 54 49 46 44 40 39 35 35 30 31 27 29 24 26 22 24 20 22 18

10 52 43 37 31 27 24 21 19 17 15

50 45 40 36 32 29 26 24 22 20 19

50 30 44 38 33 29 26 23 21 19 17 15

10 43 36 31 27 23 20 18 16 15 13

Indoor Candela Plot 0 0 22 19 17 15 13 12 11 10 9 8

135

165

180

165

150

135

900

120

120 450

105

105

90

90

75

75 450

60

60

900 45

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

150

30

15

270.0-90.0

0

15

30

45

180.0-0.0

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

64.2% 61 Yes-VDT Intensive Use $3.93 based on 3000 hrs. and $0.08 per KWH

Page 3/3 Rev. 06/14/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Test Date 10/28/94

Beams / MS6 WM