NSSR1601 USA Instructions

Report 7 Downloads 60 Views
Assembly Instructions

Shelter Type: SR1601 Email : [email protected] Web : www.nobutts.com Tel : 1-888-662-8887

SR1601-05-09032017-USA

EXPLODED VIEW

13

12

14

11

4 8

7

2 6 9 1

18 14 5

10

3

15

Tools required: Drill/Screwdriver

Spanner

Mallet

Torx bit

Hack saw 2

PARTS LIST ITEM NO. PART NO. DESCRIPTION

DIMENSION

IMAGE

QTY.

1

S1

Frame

3 3 78 4 x 40 4

2

2

S3/20

Frame

3 3 78 4 x 20 4

1

3

JF1

Bracket

5 5 1 8 8x1 8x 8

2

4

CB1

Bracket

1 7 1 4 3x1 8x 8

4

5

S3/60

Frame

3 1 78 4 x 20 3

1

6

RB2

Bracket

1 7 1 4 3x1 8x 8

4

7

R3

Rafter

3 40 4

3

8

L3

Bracket

7 1 1 2 8x1 2x 8

2

9

L1

Bracket

3 3 1 3 4x1 4x 8

4

10

B2

Beam

5 82 8

1

11

SS

Sealing Strip

3 Trim to 42 8

8

12

PCE1

Roof Panel

1 3 45 4 x 41 8

2

13

RC1

Roof Strip

1 44 2

3

14

2MD

Roof Edge

1 41 2

4

15

FT1

Foot Bracket

1 1 4 3x4x 8

5

18

EC40

Square Plastic End Cap

1 1 1 2x1 2

8

Fittings Bolt set M10 M10 x 60

Pack A Required Spare

Nut

T25

30

30

60

8

8

16

22

T50

25mm 50mm Washer Black Cap Tech Tech

22

44

Image

3

60 44 16

screw

72 32

40

AB1210

M10 x 100 Concrete Bolt screw

30

8

12

3

18

5

Step 1 Assemble main frame using S1 and S3 welded Frames. Join the frames

using CB1 brackets in the corners and JF1 brackets for the flat joints. Then move the shelter to its final position, attach FT1 foot brackets and use the concrete bolts to secure it to the ground.

7

51

GENERAL NOTE: THE 50mm TECH SCREWS ARE FOR FIXING ROOF STRIPS (RC) ONLY

S1

21

10

CB1

S1

JF1

S3

CB1

CB1 JF1 FT1

S3

Check dimensions to ensure correct alignment

FT1

ENSURE CORRECT ALIGNMENT ON BOTH SIDES

4

Step 2 Attach R3 rafters using RB2 brackets at rear and L3 brackets in the centre.

RB2

R3

RB2

R3

L3

R3 S1

L3

RB2

R3 R3

RB2

L3 R3

5

RB2

Step 3

Attach L1 brackets to R3 rafters. Then attach B2 tie bar.

R3

L1 B2 L1

L1 L1

B2

6

Step 4 Apply sealing strips to R3 rafters then put the PCE1 Panels on top,

apply more sealing strips on top of the panels and secure down with RC1 strips. Then attach the 2MD edge trim. RC1

APPLY SEALING STRIP TO ON TOP AND UNDERNEATH THE ROOF PANEL

SEALING STRIP PCE1

2MD

2MD

RC1 PCE1

2MD RC1

7

PLAN VIEW Suggested size for concrete base: 200mm oversized on all four sides 426

938

2110

2181 HOLE CENTRES (FT1 BRACKETS)

1035

63

140

471 1157 8

Notes:

9

Notes:

10

Notes:

11

THANK YOU FOR PURCHASING THIS PRODUCT

MAINTENANCE: To ensure your product gives you many years of use we recommend that you: • • •

Clean panels regularly with soapy water Ensure all fittings are tight (for example after a big storm) Touch up any exposed metal should it get scratched

CONTACT DETAILS: Email : [email protected] Web : www.nobutts.com Tel : 1-888-662-8887 No Butts Bin Company, Inc. 16 Birch Lane, Madison, CT 06443

All Parts and Fixings checked by: Print Name:

Signature:

12