OLIVETO CONTEMPO (2c)

Report 6 Downloads 47 Views
10,890 O/ALL 4,990

230

230

8,130

DINING / KITCHEN

230

4,570

90

4,570

90

THEATRE / PASS

230

3,600

230 90 510 90 1,300 1,480

BATH 2

1,300

PTY 90 / D

BATH 2

230

SCULL

600

3,780

LIN

PIER

B 9

TIMBER TRIM SHOWN DASHED (REFER DETAIL SHT)

RENDERED PIER W/- TIE DOWN ROD (T.O.F. @ -02c)

25x1210 DP

PAVED @ -1c

2,610

FAMILY

CEILINGS @ 28c UNLESS NOTED OTHERWISE

ALFRESCO

25x2410 SD

LINE OF UPPER FLOOR WALL OVER

25x2410

3,000

ALFRESCO

2,410

230

LDRY

390

3,210

DP EV

BRICKLAYER NOTE : EXTERNAL BRICKS TO BE 290 x 162 x 90 (1st external course to be a 2 course brick)

490

ALFRESCO

3

25x1210

1,610

P/BOARD CL @ 25c (26c AFL)

MH

3,000

FAMILY

990 200

1,810

590

4,530

800

230

230

1,210

2,410

230

EXTENT OF CAVITY INSULATION

590

1,990

3,000

1,210

ALFRESCO

2

290

2,300

390

ALL ROOF BEAMS SHOWN DIAGRAMMATIC ONLY. CONVENTIONAL TIMBER FRAMED ROOF IN ACCORDANCE WITH AS 1684. STRUCTURAL STEEL IN ACCORDANCE WITH NCC 3.4.4. L.V.L's IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. CEILING JOISTS @ 450 CENTERS IN OPEN PLAN LIVING AREA. PROVIDE WESPINE H2 BLUE TREATED TIMBER TO ROOF STRUCTURE.

3,600 290

PIER

ROOF FRAMING NOTES:

25x1810 A

T.O.F. -4c

NOTES:

B 9

5,700

4,110

DP

4,700

4,700

1,800

1,800

GARAGE

GARAGE

7,990

EXTENT OF CONTRAST

90 RENDER (SHOWN DASHED) 410 90

WIND CLASSIFICATION "N1" T-BAR @ 25c W/ 190w COASTAL CAT_N/A (APPROX. >10km) 590 BWK OVER EXTERNAL WALLS CONSIST OF 230 WIDE CAVITY BRICK CONST., UNLESS NOTED OTHERWISE. 90mm EXTERNAL LEAF & 90mm 1,610 INTERNAL LEAF. ALL DIMENSIONS INDICATED ON PLANS ARE TO BRICKWORK ONLY. ROOM & OPENING SIZE WILL BE REDUCED WITH PLASTER FINISH. ALL INTERNAL WALLS ARE PLASTERED UNLESS NOTED 230 2,160 90 2,320 90 OTHERWISE. ST ENTRY RECTANGULAR DOWNPIPES. DOWNPIPE POSITION AT PLUMBERS 230 2,730 90 1,750 90 DISCRETION FINAL POSITION MAY VARY TO PLAN. STUDY ENTRY 110 PROVIDE R 4.0 CEILING INSULATION (INCL. VERTICALS) TO HOUSE 230 2,730 230 1,610 90 90 AND GARAGE AREA ONLY. STUDY PORCH 150 PROVIDE R 1.3 CAVITY INSULATION TO EXTERNAL CAVITY WALLS 690 1,810 690 1,260 290 AS INDICATED. PROVIDE WEATHER SEAL TO ENTRY AND SHOPPER DOORS (ALL 3,190 1,700 EDGES) REFER ADDENDA FOR DOOR AND DOOR FURNITURE INFO. PROVIDE COLD PLUMBING TO DISHWASHER RECESS. PROVIDE E-VENT/S & EAVE VENTS AS INDICATED.

490

5,010

4

1

4c FLOORTECH

6,090

GARAGE O/ALL

RENDER TO ENTIRE HOUSE (EXCL. ZERO LOT WALL & GARAGE INTERNAL WALLS)

5,910

90

GARAGE

5,710

90

GARAGE

SUPERVISOR / BRICKLAYER NOTES: BUILT IN CAVITY PVC PIPES TO BE IN ONE LENGTH WITH NO JOINS.

SUPERVISOR / PLUMBER NOTES: PLUMBER TO CHECK LOCATION OF ALL UPPER FLOOR WET AREAS. ALL PLUMBING PIPES TO BE CONCEALED FROM BELOW. PLUMBER TO NOTIFY SUPERVISOR IF NO ALLOWANCE HAS BEEN MADE ON THE PLAN BEFORE PROCEEDING. ALL WC VENT PIPES ON EXTERNAL WALLS TO BE CONCEALED IN CAVITY.

6,000

6,000

10,890 O/ALL

DRAWING NAME THIS IS ONE OF THE DRAWINGS HOUSE NAME Home Group WA P/L reserves the REFERRED TO IN THE CONTRACT right to vary dimensions and OLIVETO CONTEMPO (2c) materials from those on display Please check plans, specification DATED: .............../.............../............... AREAS & PERIMETERS: VARIATIONS and addenda carefully. UF House Area 115.83 Rev No. Variation: Date Drn: All dimensions to take preference GF House Area 114.33 B 11357H2S VO1 VO2 16/09/14 over scaling Garage Area 36.12

SHEET No.

REVISION No. JOB No.

GROUND FLOOR PLAN 2 OF 10

.......................... OWNER

11 DELAWNEY STREET BALCATTA W.A. 6021 PHONE : (08) 6241 4555 FACSIMILE : (08) 6241 4455 www.homegroupWA.com.au

© Home Group WA Pty Ltd This work shall remain the sole property of Home Group WA .......................... Pty Ltd and may not be given, lent, OWNER resold or otherwise disposed, copied or reproduced without Home Group WA Pty Ltd’s express .......................... written consent. BUILDER

.......................... WITNESS

Alfresco Area Porch Area

10.80 2.09 279.17 m2

.......................... WITNESS

GF Perimeter UF Perimeter

56.16 45.56

GF Roof Area UF Roof Area

57.41 139.61 197.02 m2

.......................... WITNESS

17,190 O/ALL

1,990

1,110 1,990

90

LDRY

D LIN

90

1,670 230

PTY

90 250 90 1,330 1,410

1,900 190

290

1,410

5,810

AUTO-SECTIONAL DOOR BWK ON T-BAR @ 25c

4,590

KITCHEN

90

LINE OF UPPER FLOOR WALL OVER

1,410

12x1110

ZERO LOT WALL @ 31c w/- HOMEGARD GT CAVITY FILL TERMITE BARRIER (REFER DETAIL SHT.)

200

290

1,220

100

PTY LIN

2 x FULL HT. SLDRS (SOFFIT CEIL.)

2nd FACE OF BWK TO INSIDE OF GARAGE

D1

190

DP

ATTACHED 100 PIERS

500

PAVED @ -1c

CAVITY DP

PLASTERBOARD CEILING @ 28c (29c AFL)

5,810

PLASTERBOARD CEILING @ 28c (29c AFL)

GRANO @ -1c

300

500 190

PORCH

T.O.F. -4c

2,310

A 9

1,010

200

1,200 L TDF

INSET WM TR REC

D2

290

STUDY DP

ENTRY

1,400

820L

LDRY

290 1,010 290

290

450 x 510 SLAB PENETRATION FOR A/C

DP

1,010

1112

FW

25x1610 SD

190

ST

4 x 450D SH'S

GARAGE

190

5,810

10

S

720L

2x620 DW 830W FHO REC

WALL VENT FOR BATH 2 EXHAUST

BRICK CAVITY CLOSER W/- ALCOR FLASHING

1,410

9

290

TO NCC REQUIREMENTS

910

UP HANDRAIL

820R 3 x HINGES

SCULL

820L 3 x HINGES

200

7 6 5 4 3 2 1

PLUMB. DUCT W/ 1x ACCESS PANEL ( REFER ROOM LAYOUTS)

2

290

90

3,470

GAS/ELECTRIC METERBOX EXTENT OF CAVITY INSULATION

SHR

370 x 510 SLAB PENETRATIONS FOR A/C EXPOSED CHROME 720L THEATRE TRAP (WASTE PIPE LOHFW CHASED INTO WALL) BATH

25x2410

3,170

1,530

DP

GAS HWU ON CONC. SLAB

120

400 x 510 SLAB PENETRATIONS FOR A/C 4 x 450D SH'S (CL@ 25c)

WALL VENT FOR R/HOOD EXHAUST

ZERO LOT WALL @ 31c w/- KORDON TMB (REFER DETAIL SHT.)

25x2410

HARDIFLEX LINED SPANDREL END

GARAGE

ST

230

230 4,110 90

DP

8

3,370 STUDY 300 110 90 190

90

HARDIFLEX LINED SPANDREL END

DINING

90 955 90 955

90 2,000

STAIRS

90 3,370

STUDY

230

FR/FZ REC

FL. CANOPY R/HOOD UBO HP

3,470

BATH 2

190 3,880

THEATRE

190 THEATRE

3,880

1,290 2,410 6,590

230

KITCHEN

DP

A 9 17,190 O/ALL

LOCKABLE MANHOLE

EV

KITCHEN

7,110

DINING / FAMILY

7,110

DINING / FAMILY

2,410

1,490

25x1810

C

11357H2S VO3

09/12/14

CLIENT NAME

C

11357H2S

DANIEL & BIJU

By: HP DB SITE ADDRESS

LOT 116 BELLAS CIRCUIT PIARA WATERS SHIRE

CITY OF ARMADALE

Drawn By HP

Date Drawn. 16/09/14

Scale. 1:100

Checked.

PRINTED : 9/12/2014 | DATE SAVED : 9/12/2014 2:54 PM | BY : danielle.baker | TO: G:\Client Documents\11300H\11357H2S - DANIEL & BIJU\Drafting\Working Drawings Files\11357H2S BIJU.pln