P4D22-3 - Columbia Lighting

Report 7 Downloads 160 Views
P4D22-3

2' × 2' DuraLouver® Parabolic / 3-Lamp T8, TT Project Information Project Name

Type

Catalog No.

Date

Construction

Luminaire housing and end caps are die formed code gauge cold rolled steel. Louver is formed from DuraLouver® anodized aluminum and secured in open or closed position by die formed steel hinges. Louver hinges from either side. Mechanical light trap prevents light leaks. Latches are finger-tip actuated, positive feed type, fabricated of spring steel, and completely concealed in the black reveal.

Also available with 16 cells

Features • • • • • • • • • •

Nominal 3" deep louver Fluorescent, energy efficient light source Black reveal with full air handling capabilities Matte anodized low iridescent, semi-specular (MA) louver finish virtually eliminates visibility of fingerprints and construction dust Shallow housing height Lightweight Also available in 2-lamp or 4-lamp configurations Recessed, surface or cable mount UL Listed 1598 Available with exclusive wiHUBB technology preinstalled – Peer to peer, self-healing wireless mesh network – Integrated control system for 0-10VDC or On/Off

22

Model



Finish

AIR HANDLING

Designed for recessed installation in standard inverted tee grid ceilings (G), recessed installation in hard ceilings (G with FK accessory), Surface mount at ceiling plane (SM) or cable mount suspension below ceiling plane (CM). For compatibility with specific ceilings contact your Hubbell Lighting representative.

Parts are treated with a five stage phosphate bonding process and finished with a high temperature baked white enamel. For post painted housing, suffix catalog number with PAF. Regressed slots are flat black. Anodized aluminum DuraLouver standard finish is matte anodized low iridescent (MA). Also available in low-iridescent specular aluminum (LS). All supply/return and air extract functions are available as a specified option. Directional control vanes and/or extract damper features available. Air extract slots are located out of sight in end caps. See air removal data on reverse.

P4D DuraLouver Parabolic

3 Three

Size 22 2' x 2'

– Ceiling Type G Inverted T-bar SM Surface Mount (static only)3 CM Cable Mount (static only)2,3 For hard ceilings use flange kit; see accessories.

1

– NO. CELLS CROSSWISE

Certification

All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.

3 Three 4 Four

3 Three 4 Four

Lamp Type

Louver Finish

FK22 2' × 2' Single Flange Kit FKCR Flange Kit Row Adapter Brackets CM48Y2SC3F-KIT 48" Cable Mount Kit for 2' Wide CM Trim Fixtures, 3 Wire Feed Cord

31U1 U-Bent, 15/8" Leg Spacing T8: 31 Watt 40TT Twin Tube Compact, 2G11 Base: 40 Watt 17 2', T8: 17 Watt

MA Matte Anodized Low Iridescent Semi-Specular Aluminum (std.) LS Low Iridescent Specular Aluminum

For drywall order G ceiling type with FK flange kit accessories. 2 Order hanger accessories separately. 3 Contact factory for continuous row, 3-lamp fixtures. 4 EL or other options may increase fixture depth. 5 In-Fixture module antenna adds 2" to overall fixture height at powerfeed location. 6 Not available with Surface Mount ceiling type. Protected by US Patent 6,582,098. Specifications subject to change without notice.



NO. CELLS LENGTHWISE

Accessories

– Ballast

S A AV C CV CD CVD H HD

Options 4

E Electronic T8, Instant Start 3E 3-Lamp Electronic T8, Instant Start EPTT Electronic Twin Tube, Programmed Start (40TT) For a specific ballast vendor show as option.

AIR FUNCTIONS

1

Page 1/3 Rev. 07/05/13

Ceiling Compatibility

Example P4D22-317G-MA33-S-3EU

3

No. of Lamps

Electrical

Standard class “P”, thermally protected, auto-resetting HPF ballast, sound rated A. All ballast leads extend a minimum of 6" through access location. NEC/CEC-compliant ballast disconnect is standard.

Ordering Information P4D

Installation

An access plate is furnished with each luminaire for fast wiring access from the plenum. No need to open fixture. Product ships standard with mylar dust cover to eliminate job site contamination.

Static Air Handling Air Handling w/Supply Vanes Combination Supply/Extract Combination Supply Vanes/ Extract Combination Supply Extract Dampers Combination Supply Vanes Extract Dampers Heat Extract Heat Extract w/Dampers

Voltage U 120V-277V 347 347V

GLR GMF EL C388 C488 TB4 MS9 PAF NYC NYCU WIH

Fast Blow Fuse Slow Blow Fuse Emergency Battery Pack 3-Wire Flex 4-Wire Flex Four Bulk T-bar Clips Master/Satellite w/9' Harness Paint After Fabrication NYC Compliant NYC Compliant, Union Label wiHUBB Enabled5,6

Parabolics / P4D22-3

© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com

P4D22-3

2' × 2' DuraLouver® Parabolic / 3-Lamp T8, TT

Photometric Data

Test 12463 Test Date 3/21/00

Luminaire Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion

P4D22-331U1-MA33 P4D, Parabolic 2' X 2' 3 LAMP WITH 3X3 CELL SEMI-SPECULAR LOUVER B332I120RH 0.88 F31U1 2725 80 0º = 21 90º = 37 0º = 1.20 90º = 1.38

Energy Data

Zone

Lumens

Lamp

Fixt.

Total Luminaire Efficiency

62.4%

0-30 0-40 0-60 0-90 0-180

1720 2828 4674 5103 5103

21.0 34.6 57.2 62.4 62.4

33.7 55.4 91.6 100.0 100.0

Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

56 Noncompliant $4.29 based on 3000 hrs. and $0.08 per KWH

AVG. LUMINANCE (Candela/Sq. M.) 0.0 22.5 45.0 67.5 90.0

Indoor Candela Plot 90

RCR

Coefficients of Utilization (%) RC RW 1 2 3 4 5 6 7 8 9 10

70 69 64 59 54 50 47 43 40 38 35

80 50 30 67 65 60 56 53 49 48 43 43 38 39 34 35 30 32 27 30 25 27 23

10 63 53 45 39 34 30 27 24 22 20

70 68 62 57 53 49 45 42 39 37 35

70 50 30 66 64 59 55 52 48 47 42 42 38 38 33 35 30 32 27 29 25 27 23

10 62 52 45 39 34 30 27 24 22 20

50 63 56 50 45 41 37 34 31 29 27

50 30 61 54 47 41 37 33 30 27 24 22

10 60 51 44 38 34 30 26 24 21 20

0 0 55 48 41 36 32 28 25 22 20 18

75

1200 60

0 30 40 45 50 55 60 65 70 75 80 85

7711 7266 6989 6778 6460 6000 5383 4122 1331 495 287 204

7711 7718 7723 7612 7273 6626 5475 3659 1383 481 307 204

7711 8486 8108 7678 7163 5703 4309 3155 1289 398 266 204

7711 8818 8451 7778 5824 5095 4793 2482 582 343 246 163

7711 8913 8790 7572 5791 5820 5212 2322 499 316 205 122

2400 0

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Average Luminance Angle

Luminaire

Zonal Lumen Summary

15

0.0

Dimensional data

30 Horiz 0-180 45.0

45

90.0

Ceiling Compatibility Type G

53/16"

FK22 Flange Kit

313/16" 211/16" 24"

Side

253/4" 3/8"

For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed.

24" 13/4"

FKCR 33/4"

24"

1/4" Diffuser Mtg. K.O. 3/16" High Embossed

253/4"

End

2" × 3" F-Cap Hole

Side

End

For hard ceiling applications order FK22 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK22 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK22 & (1) FKCR)

Row cut out dimensions using FK22s & FKCR adapters: Width 243/8", Length [24" × (# in row)] + 3/8". Example: (24" × 2) + 3/8" = 483/8" Flange kit rough in dimensions for single unit only: 243/8" × 243/8"

NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.

Page 2/3 Rev. 07/05/13

Parabolics / P4D22-3

© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com

P4D22-3

2' × 2' DuraLouver® Parabolic / 3-Lamp T8, TT Dimensional Data - surface or cable mount 191⁄8" (4) 1⁄4–1⁄2" K.O. Mounting Locations, "A"

NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.

75⁄8"

15"

11⁄2" K.O. 41⁄2" x 5" Mounting Collar (SM only). For Cable Mount (CM) a 2" x 3" access plate with (2) 7⁄8" K.O.s provided in place of Mounting Collar shown.

31⁄8"

End View

Side View

25"

25" 51⁄4"

SURFACE MOUNT

CABLE MOUNT

Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 1⁄4" to 1⁄2" provided as shown, marked "A".

Order CM ceiling type. Access plate supplied for cable mounting or suspension. Use CM48Y2C3F-KIT 48" cable mount kit. Includes 3 wire feed cord. For other wiring needs, contact Hubbell Lighting representative. Mounting knock-outs, 1⁄4" to 1⁄2", provided as shown, marked "A".

Page 3/3 Rev. 07/05/13

Parabolics / P4D22-3

© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com