S & C SERIES 1800 Series
2CH 1820-009
pilots and ignitors
1820 SERIES PG9 REPLACEMENT PILOT UNI-KITS® The 1820 Series Uni-Kits are designed to replace those hard-to-find ITT-General PG9 type pilots. Most Uni-Kits come with a natural gas orifice installed and a separate LP gas orifice. A special 1/4”[6.35mm] tubing adaptor is typicallu provided with nut and ball sleeve. Uni-Kits are available with and without a 32” thermopile. These 1820 Pilot UniKits are aerated type pilots, combining the best feature of an incinerator type pilot and a target type pilot. These pilots have nonlinting characteristics, and no air shutters or supplementary shields requiring assembly or adjustment.
1830 (2CH & 2C SERIES) INCINERATORTARGET PILOT UNI-KITS 6CH24-6 1830-490
The 1830 Series Pilot Uni-Kits is designed to be used with all Robertshaw® and competitive thermocouples. Uni-Kits include an adaptor that converts a threaded thermocouple/thermopile model 2CH to a snap-in thermocouple type, model 2C. Most kits come with a natural gas orifice installed and a separate LP gas orifice. Pilot tubing size is typically 1/4” [6.35mm] tubing. These 1830 Pilot Uni-Kits are aerated type pilots, combining the best feature of an incinerator type pilot and a target type pilot. These pilots have non-linting characteristics, and no air shutters or supplementary shields requiring assembly or adjustment are needed.
1830-700 SERIES PILOT ELECTRODES 6S14-2ER 1830-717
Specifications • Pilot tubing ¼” [6.35mm] • Incinerator type pilots • Natural gas or LP • Various lead lengths 13” to 48” [330 mm to 1220 mm] • Various flame hoods (1, 2 or 3) with different orientations • Left or right hand flame orientations
The 1830-700 Series Pilot Uni-Kits are designed for use with the OEM-style Pilot Ignition systems. The electrode is permanently riveted to the pilot frame and the spark gap is fixed at 1/8” [3.18mm]. These pilots can be used to replace existing pilot assemblies or for retrofitting standing pilot applications when an exact replacement is desired. Most Uni-Kits come with a natural gas orifice installed and a separate L.P. gas orifice. Pilot tubing size is typically 1/4”[6.35mm]. The 1830 Pilot Uni-Kits are aerated type pilots, combining the best feature of an incinerator type pilot and a target type pilot. These pilots have non-linting characteristics, no air shutters or supplementary shields requiring assembly or adjustment.
Features and Benefits • Many flame pattern types available • Thermocouple or thermopile options • Spark electrode available • Horizontal or vertical gas inlet • Several mounting bracket types
S & C SERIES 1800 Series
PILOT MODEL TYPE IDENTIFICATION ELECTRODE LOCATION “E” = End “F” = Front BRACKET TYPE (7 Types) HOOD WIDTH (Type 6 Only) First digit is for increments of one inch [25.4mm] Second digit is for number of increments in 1/8” [3.18mm]
HOOD TYPE (5 Types) PILOT TYPE C Thermocouple Type CH
Thermopile Type
S
Spark Electrode
SH
Spark with Thermopile
Note:
Uni-Kits® are “CH” type with adaptor to convert to “C” type
HOOD TYPE
FLAME PATTERN TYPE
2 CH AL 24-6
DRAFT SHIELD (Optional)
FLAME PATTERN “L” for Left Hand “R” for Right Hand
MOUNTING BRACKET TYPE
pilots and ignitors
pilots and ignitors
S & C SERIES 1800 Series
1-33/64 [1.51] Dia.
21/64 [8.3]
DIMENSIONAL DRAWINGS Visit www.Uni-Line.com for more product information.
2C
11/32 [8.7]
1-33/64 [1.51] Dia.
CL
21/64 [8.3]
inches mm
25/32 [19.8]
#10 - 32 NF Thd
0.360 [9.1] Dia.
1-1/8 [28.6]
3/32 [2.4] Typ. 1/2 [12.7]
1-33/64 [1.51] Dia.
21/64 [8.3]
CL
1-7/16 [36.5]
25/32 [19.8]
11/16 [17.4]
1-1/8 [28.6]
25/32 [19.8] 0.360 [9.1] Dia.
3/32 [2.4] Typ.
7/16 5/32 - 27 [NS-2 3.9] Thd
1-29/64 [ 36.9] 21/64 [ 8.3]
11/32 [8.7] #10 - 32 NF Thd
7/8 [22.2]
1-3/16 [30.1]
11/32 1/2 [8.7] [12.7]
CL Dimensions are: inches [milliimeters]
3/32 [2.4]
Removable orifice spud Ball sleeve
1/2 [12.7]
11/32 [8.7]
1/2 [12.7]
3C
7/8 [22.2]
1-3/16 [30.1]
25/32 [19.8] 1-29/64 [ 36.9] 1-7/16 [36.5]
7/16 - 27 NS-2 Thd
21/64 [ 8.3]
d
1-1/8 [28.6]
11/16 [17.4]
CL
11/32 [8.7]
25/32 [19.8]
0.360 [9.1] Dia. 3/32 [2.4] Typ. Dimensions are: inches [milliimeters]
3/32 [2.4]
Removable orifice spud Ball sleeve
7/8 [22.2]
1-3/16 [30.1]
Compression nut for 1/4 tubing
5/32 [ 3.9]
25/32 [19.8] 19/64 [7.5]
3/4 [19]
7/16 - 27 NS-2 Thd
Compression nut for 1/4 tubing 1-15/64 [31.3]
Dimensions are: inches [milliimeters]
3/8 [9.5]
3/8 [9.5] 0.360 [9.1]
Removable orifice spud Ball sleeve
9/32 [7.1]
3/32 [2.4]
11/16 [17.4]
0.195 [ 4.9] Dia.
25/32 [19.8] 19/64 [7.5] 3/4 [19]
31.3]
Compression nut for 1/4 tubing
Ball sleeve Compression nut for 1/4 tubing
3/8 [9.5]
7/16-27 N.S.-2 THD
Removable orifice spud
3/8 [9.5] 0.360 [9.1]
Dimensions are: inches [milliimeters]
1-29/64 [ 36.9]
5/32 [ 3.9] 21/64 [ 8.3]
S & C SERIES 1800 Series 11/16 [17.4]
CL
pilots and ignitors
3/32 [2.4]
DIMENSIONAL DRAWINGS Visit www.Uni-Line.com for more product information.
4C
inches mm
25/32 [19.8] 1-29/64 [ 36.9]
5/32 [ 3.9]
3/8 [9.5]
19/64 [7.5]
21/64 [ 8.3] 11/16 [17.4]
CL
3/32 [2.4]
1-15/64 [31.3]
3/8 [9.5]
3/8 [9.5] Dia. 0.360 [9.1]
3/32 [2.4]
9/32 [7.1] 0.195 [4.9]
1-5/16 [ 33.3]
11/16 [17.4]
7/16-27 N.S.-2 THD 5/32 [ 3.9]
Removable orifice spud Ball sleeve
11/16 [17.4]
Dimensions are: inches 3/32 [2.4] [milliimeters]
Compression nut for 1/4 tubing
CL
25/32 [19.8] 3/8 [9.5]
19/64 [7.5]
5C
64 [31.3]
3/8 [9.5]
25/32 [19.8]
3/8 [9.5] Dia.
5/32 [ 3.9]
0.360 [9.1]
19/64 [7.5] 13/32 [10.3] Typ.
9/32 [7.1]
3/32 [2.4]
3/32 [2.4]
Thermocouple 11/16 [17.4]
0.195 [4.9]
7/16-27 N.S.-2 1-29/64 THD [36.9] 1-15/64 [31.3]
Removable orifice spud
3/8 [9.5] Dia.
Ball sleeve Dimensions are: inches [milliimeters]
Compression nut 1-5/16 [ 33.3] for 1/4 tubing
9/32 [ 7.1]
3/8 [9.5]
3/32 [2.4]
31/64 [12.3]
3/8 [ 9.5]
25/32 [19.8] 19/64 [7.5]
5/32 [ 3.9]
0.195 [ 4.9] Dia. 11/16 [17.4]
CL
3/32 [2.4] 13/32 [10.3] Typ.
Thermocouple
Removable orifice spud Ball sleeve Compression nut for 1/4 tubing
3/8 [9.5] Dia.
25/32 [19.8]
9/32 [ 7.1]
31/64 [12.3]
3/32 [2.4] 191 E. North Avenue Carol Stream Illinois 60188 USA 3/8 [ 9.5] Customer Service Telephone 1.800.304.6563 Customer Service Facsimile 1.800.426.0804
[email protected] Removable orifice spud 1-29/64
19/64 [7.5] ® Invensys™, Robertshaw®, Uni-Kit®, Uni-Line For Technical Service , and Simply the Right Choice™ 13/32 [10.3] Typ. Telephone 1.800.445.8299 are trademarks of Invensys plc., its subsidiaries and/or affiliated Thermocouple Facsimile 1.630.260.7294 companies. All other brands mentioned may be the trademarks of
[email protected] their respective owners.
www.Uni-Line.com www.InvensysControls.com ©2012 Invensys Controls
09/12 – 150-2377