PMA Leading in Cable Protection Systems PMA Reference Guide*
PMAFLEX: Common Conduit Conversions
NW
PG
Metric
Conduit Size
Conduit ID mm / in
Conduit OD mm / in
7 10 12 17 23 29 36 48
7 9 11 13.5 21 29 36 48
m10 m12 m16 m20 m25 m32 m40 m50 or m63
¼" ¾" 8 ½" ½" ¾" 1" 1 ¼" 1 ½" or 2"
6.20 / 0.24 9.60 / 0.38 12.00 / 0.47 16.20 / 0.64 22.60 / 0.89 29.00 / 1.14 36.50 / 1.44 47.50 / 1.87
10.00 / 0.39 13.00 / 0.51 15.80 / 0.62 21.20 / 0.83 28.50 / 1.12 34.50 / 1.36 42.50 / 1.67 54.50 / 2.15
PMAFIX: Common Fitting Conversions Nema Rating vs. IP Rating Nema IP 12 12k 13 4 4x 6 6p
IP54 IP54 IP54 IP66 IP66 IP67 IP68
Bar vs. PSI Bar PSI
IP69KHigh Pressure Wash Down (up to 80 bar / 1160psi) from any angle
1 80 100
14.5 1160 1450
PG
mm / in
7 9 11 13.5 16 21 29 36 48
12.7 / 0.50 15.4 / 0.61 18.8 / 0.74 20.7 / 0.81 22.8 / 0.90 28.6 / 1.13 37.4 / 1.47 47.5 / 1.87 59.8 / 2.35
Panel Cut Out Hole Size Metric mm / in NPT 12 16 20 20 25 32 40 50 63
12 / 0.47 16 / 0.63 20 / 0.79 20 / 0.79 25 / 0.98 32 / 1.26 40 / 1.57 50 / 1.97 63 / 2.48
¼" ¾" 8 ½" ½" ¾" 1" 1¼" 1½" 2"
General: Common Conversions Length 1 Foot 1 Meter 1 Inch 1 Millimeter 1 Inch 1 Centimeter
= = = = = =
Weight
0.305 Meter 3.281 Feet 25.4 Millimeters 0.039 Inches 2.54 Centimeters 0.394 Inches
1 Pound 1 Pound 1 Kilogram 1 Gram 1 Ounce
= = = = =
454 Grams 0.454 Kilograms 2.205 Pounds 0.035 Ounces 28.349 Grams
Temperature C F C F
= = = =
Degrees Centigrade Degrees Fahrenheit (F-32)/1.8 (Cx1.8)+32
*This guide is designed as a reference tool only and not meant to indicate exact substitutions. PMA AG · Aathalstrasse 90 · 8610 Uster · Tel.: +41 (0)44 905 61 11 · Fax: +41 (0)44 905 61 22 ·
[email protected] · www.pma.ch
mm / in 13.9 / 0.55 17.4 / 0.69 21.6 / 0.85 21.6 / 0.85 26.9 / 1.06 33.7 / 1.33 42.4 / 1.67 48.5 / 1.91 60.6 / 2.39
PMA Leading in Cable Protection Systems PMA Reference Guide
Assembly Instructions** IP66 (PMAFIX, PMA Smart Line)
IP68 (PMAFIX)
IP69K (PMAFIX Pro)
conduit
ribbed sealing area
fitting
fitting concave interior form
conduit
fitting
conduit
seal cap
schematic diagram schematic diagram
schematic diagram
ribbed sealing area
clip seal cap conduit
conduit
conduit
fitting
fitting
clip
thread seal or O-ring
thread seal or O-ring
fitting
**For more information refer to: www.pma.ch/pma_com/downloads/download_man.html
Application Guide*** Outdoor Applications no
yes
Continuous Flex Application? Reverse Bending / Automation / Robotic?
Continuous Flex Application? Environmental Condition / Climate Temperature?
no
yes
no
PA 6 Conduit Type
PA 12 Conduit Type PCS, PIS, LLPI
PA 6 Conduit Type
Flame Protection Required / Human Safety?
High Mechanical Strength / Rigidity?
yes
yes
VAM/L, LLPF
no PCL, CYL, LLPF
***For more information refer to: www.pma.ch/pma_com/guide.php PMA AG · Aathalstrasse 90 · 8610 Uster · Tel.: +41 (0)44 905 61 11 · Fax: +41 (0)44 905 61 22 ·
[email protected] · www.pma.ch
VOH, VCS