Pre-Wired IEC Enclosed Starters

Report 12 Downloads 132 Views
3 Phase — Non-reversing

Setting the standard

Schneider Electric has been saving you time and money with InstaKits motor starters since 1989. They are the number one choice of contractors and end users who have come to rely on our design, engineering and efficiency. We know pre-wired motor starters better than anyone else because we invented the concept with InstaKits.

Maximum Horsepower Rating 280V 230V 460V 575V

Save time. Save money. Eliminate frustration.

Our InstaKits motor starters are one of the most flexible products on the market today. Their ease of installation can save you time and money during installation. Plus, simple plug-in components helps to eliminate frustrations caused by complex wiring.

Anything else is a compromise

Our InstaKits motor starters meet globally accepted standards; including UL, CSA, IEC and ISO.

A worldwide presence

Schneider Electric is a global supplier of electrical distribution, automation and control equipment products under the brand names of Square D®, Telemecanique® and Merlin Gerin®. Backed by a global organization of 90,000 employees in 190 countries, Schneider Electric is a global electrical industry leader. With one of the strongest distribution networks in the U.S. and around the world, you can count on Schneider Electric to keep your business running smoothly and efficiently.

Schneider Electric provides you with technical assistance throughout the world. Visit our web site at: www.us.telemecanique.com

Schneider Electric - North American Operating Division 1415 S. Roselle Road Palatine, IL 60067 Tel: 847-397-2600 Fax: 847-925-7543 Document Number 8536BR0801

04-08 lh

Non-Combination

Combination Fusible

Combination Circuit Breaker

Type 1

Type 12

Type 1

Type 12

Type 1

Type 12

Catalog Number

Catalog Number

Catalog Number

Catalog Number

Catalog Number

Catalog Number

HP

HP

HP

HP

2

2

5

7.5

LE1D093A62OG70 LE1D093A72OG70 LE1D096B62OG70 LE1D096B72OG70 LE1D097D62OG70

LE1D097D72OG70

3

3

7.5

10

LE1D123A62OG70 LE1D123A72OG70 LE1D126B62OG70 LE1D126B72OG70 LE1D127D62OG70

LE1D127D72OG70

5

5

10

15

LE1D183A62OG70 LE1D183A72OG70 LE1D186B62OG70 LE1D186B72OG70 LE1D187E62OG70

LE1D187E72OG70

7.5

7.5

15

20

LE1D253A62OG70 LE1D253A72OG70 LE1D256C62OG70 LE1D256C72OG70 LE1D257E62OG70

LE1D257E72OG70

10

10

20

25

LE1D323A62OG70 LE1D323A72OG70 LE1D326C62OG70 LE1D326C72OG70 LE1D327F62OG70

LE1D327F72OG70

10

10

30

30

LE1D403A62OG70 LE1D403A72OG70 LE1D406C62OG70 LE1D406C72OG70 LE1D407F62OG70

LE1D407F72OG70

10

15

40

40

LE1D503A62OG70 LE1D503A72OG70









20

20

50

50

LE1D653A62OG70 LE1D653A72OG70









25

30

60

60

LE1D803A62OG70 LE1D803A72OG70









3 Phase — Reversing Maximum Horsepower Rating 280V 230V 460V

©2008 Schneider Electric. All rights reserved.

Technical assistance wherever you are

(A) 1 Phase — Non-reversing

575V

Non-Combination

Combination Fusible

Combination Circuit Breaker

Type 1

Type 12

Type 1

Type 12

Type 1

Type 12

Catalog Number

Catalog Number

Catalog Number

Catalog Number

Catalog Number

Catalog Number

HP

HP

HP

HP

2

2

5

7.5

LE2D093A62OG70 LE2D093A72OG70 LE2D096B62OG70 LE2D096B72OG70 LE2D097D62OG70 LE2D097D72OG70

3

3

7.5

10

LE2D123A62OG70 LE2D123A72OG70 LE2D126B62OG70 LE2D126B72OG70 LE2D127D62OG70 LE2D127D72OG70

5

5

10

15

LE2D183A62OG70 LE2D183A72OG70 LE2D186B62OG70 LE2D186B72OG70 LE2D187E62OG70 LE2D187E72OG70

7.5

7.5

15

20

LE2D253A62OG70 LE2D253A72OG70 LE2D256C62OG70 LE2D256B72OG70 LE2D257E62OG70 LE2D257E72OG70

10

10

20

25

LE2D323A62OG70 LE2D323A72OG70 LE2D326C62OG70 LE2D326C72OG70 LE2D327F62OG70

LE2D327F72OG70

10

10

30

30

LE2D403A62OG70 LE2D403A72OG70 LE2D406C62OG70 LE2D406C72OG70 LE2D407F62OG70

LE2D407F72OG70

10

15

40

40

LE2D503A62OG70 LE2D503A72OG70









20

20

50

50

LE2D653A62OG70 LE2D653A72OG70









25

30

60

60

LE2D803A62OG70 LE2D653A7OG70









Note: Above starters include 120V dual frequency (50Hz/60Hz) coils. For other control voltages, please consult your local Schneider Electric distributor.

Maximum Horsepower Rating 120V

240V

HP 0.3

(B) Field installable operator interface kits Description

Non-Combination Type 1

Type 12

HP

Catalog Number

Catalog Number

1

LESD093A62OG70

LESD093A72OG70

One Operator

Name Plate

Catalog Number

3 Phase motor horsepower

(C) Overload relay selection* Catalog Number

Relay Setting Range

For Use with Starters LE

3 Position Selector Switch Hand-off-auto

LA9CA06ET

2 Position Selector Switch Off-on

LA9CA06DT

LRD01

0.10 to 0.16A

D09 to D32

Pilot Light Full Voltage

Power on

LA9CA06ST

LRD02

0.16 to 0.25A

D09 to D32

Pilot Light Transformer

Power on

LA9CA06FT*

LRD03

0.25 to 0.40A

D09 to D32

Power on

LA9CA16ST*

LRD04

0.40 to 0.63A

D09 to D32

Class 10 with Connection by Screw Clamp Terminals

0.5

2

LESD123A62OG70

LESD123A72OG70

Pilot Light LED

1

3

LESD183A62OG70

LESD183A72OG70

Push Button (double touch) I-O

LA9CA06IO

LRD05

0.63 to 1A

D09 to D32

2

3

LESD253A62OG70

LESD253A72OG70

2 Push Buttons

LA9CA06GT

LRD06

1 to 1.6A

D09 to D32

2

5

LESD323A62OG70

LESD323A72OG70

LRD07

1.6 to 2.5A

D09 to D32

3

5

LESD403A62OG70

LESD403A72OG70

LRD08

2.5 to 4A

D09 to D32

3

7.5

LESD503A62OG70

LESD503A72OG70

LRD10

4 to 6A

D09 to D32

5

10

LESD653A62OG70

LESD653A72OG70

LRD12

5.5 to 8A

D09 to D32

7.5

15

LESD803A62OG70

LESD803A72OG70

LRD14

7 to 10A

D09 to D32

LRD16

9 to 13A

D12 to D32

LRD21

12 to 18A

D18 to D32

LRD22

16 to 24A

D25 to D32

LRD32

23 to 32A

D25 to D32

LRD35

30 to 38A

D32

LRD3322

17 to 25A

D40 to D80

LRD3353

23 to 32A

D40 to D80

Two Operators

Ordering example: to select a 10HP, 600V FVNR starter complete with hand off auto (HOA), full voltage pilot (PL) light and 600 to 120V control transformer, Order the following components: Base Starter A. HOA with PL kit B. Control power transformer kit C. Overload relay

= LE1D123A62OG70 = LA9CA06UT = LA9TD32X = LRD16

A B

C Note: Above starters include 120V dual frequency (50Hz/60Hz) coils. For other control voltages, please consult your local Schneider Electric distributor.

Start Stop

2 Position Selector Switch Off-on + Full Voltage Pilot

LA9CA06WT*

2 Position Selector Switch Off-on power + Transformer Pilot

LA9CA06HT*

2 Position Selector Switch Off-on + LED Pilot power on

LA9CA06WT*

3 Position Selector Switch Hand-off-auto + Full Voltage Pilot power on

LA9CA06UT*

3 Position Selector Switch Hand-off-auto + Transformer Pilot power on

LA9CA06JT*

3 Position Selector Switch Hand-off-auto + LED Pilot power on

LA9CA16UT*

* Add the appropriate suffix to the catalogue number (Volts)

24V

120V

208/ 240V

480V

600V

LRD3355

30 to 40A

D40 to D80

Code

B

G

M

T

X

LRD3357

37 to 50A

D40 to D80

LRD3359

48 to 65A

D50 to D80

LRD3361

55 to 70A

D50 to D80

LRD3363

63 to 80A

D50 to D80

Note: LED type are only available for voltage codes: B, G and M. Above catalog numbers specify green pilot lights as standard. For other available InstaKit variations please consult the catalog.

Voltage control circuit transformer VA Rating

For LE1 starters

Catalog Number

50VA

D09 – D32

LA9TD32*

100VA

D40 – D80

LA9TD80*

Secondary

* These overload relays meet Class 10 trip characteristics. For Class 20 overload relays refer to the Digest or contact your local Schneider Electric distributor.

Primary

Voltage

600V

480V

240V

208V

120V

120V

X

T

M

L



24V

A

B

C

D

Replace * with suffix from above table

E



Type 2 coordination fuse selection table

200V

230V

460V

575V

HP

HP

HP

HP

Starter

Overload Relay

Pre-Wired IEC Enclosed Starters

SHAWMUT FUSES (max) Class J

Class 10 with Connection by Screw Clamp Terminals —





1/2

LE*D09

LRD05

AJT 1.5





1/2

3/4

LE*D09

LRD06

AJT 2





3/4



LE*D09

LRD06

AJT 2

1/2

1/2

1

1

LE*D09

LRD07

AJT 5







1 1/2

LE*D09

LRD07

AJT 5

3/4

3/4

1 1/2

2

LE*D09

LRD08

AJT 5





2

3

LE*D09

LRD08

AJT 5

1

1

3



LE*D09

LRD10

AJT 20

1 1/2

1 1/2



5

LE*D09

LRD12

AJT 20

2

2





LE*D09

LRD12

AJT 20





5



LE*D09

LRD14

AJT 20

3

3

7 1/2

7 1/2

LE*D12

LRD16

AJT 20







10

LE*D18

LRD16

AJT 20

5

5

10



LE*D18

LRD21

AJT 25







15

LE*D25

LRD21

AJT 25



7 1/2

15



LE*D25

LRD22

AJT 35





15

15

LE*D32

LRD22

AJT 40







20

LE*D32

LRD22

AJT 40

7 1/2

10

20

25

LE*D40

LRD32

AJT50





25



LE*D40

LRD3355

AJT 60

10



30

30

LE*D40

LRD3355

AJT 60

15

15

30

40

LE*D50

LRD3357

AJT 70





40



LE*D50

LRD3359

AJT 70

20

20

50

50

LE*D65

LRD3359

AJT 100







60

LE*D80

LRD3361

AJT 100

25

25

60



LE*D80

LRD3363

AJT 110



30





LE*D80

LRD3363

AJT 110

1

Wire to your power source and motor

2

Plug in your InstaKits

3

Start your motor

Quick Selection Guide

Save time and money with InstaKits

The InstaKits line of IEC magnetic starters allows factory-wired starters to be conveniently assembled from your local distributor's stock. InstaKits starters use a completely pre-wired universal connector, which allows for quick installation of plug-in options. Choose from a wide selection of push button kits, control transformers and userfriendly connectors for reliable remote control.

InstaKits include:

• NEMA Type 1 general purpose or NEMA Type 12 dust

• • • •

tight enclosures Maintenance-free TeSys® D-Line™ IEC style contactor Class 10 or 20 overload relay with manual or auto reset Common operator interface kits for Type 1 or 12 enclosures Provision for a control transformer kit in same size enclosure

Across the product line

• Compact space saving design • Easy component access on shallow base • Conduit entry knockouts located on all four sides

(NEMA Type 1 enclosure only)

• Padlock provision

How to get started

Combination

• Fusible type featuring Type 2 coordination • Breaker type featuring Square D® brand – circuit breakers

motor circuit protectors

• Thru the door rotary handle switch or breaker mechanism • Easy component access with hinged door

Wide range of styles • Compact design • Flexible field modification

Local control features • Pre-wired, ready-to-operate InstaKits • Push buttons, pilot lights and

selector switches



used with NEMA Type 12 enclosures

• One, two or three pilot devices • InstaKits rated NEMA Type 12 when • Single- or three-phase. • Non-reversing or reversing • Combination or

non-combination (fuse or breaker) up to 60HP at 600V

1

Wire L1, L2 and L3 to power source and T1, T2 and T3 to motor.

Adapters

Local and remote control adapters allow easy connection to external and cover mounted pilot devices. Please contact your local Schneider Electric distributor for more information.

Plug-in transformers

• • • •

2

Pre-wired and ready to install Fits in same size enclosure Control block and fuses included Costs 50% less than a factoryassembled plug-in transformer!

Plug in desired Instakits to match your specific application. The control devices assembles to the enclosure with two screws. Select from a wide range of options to meet your specific application needs including pilot devices and control power transformers.

InstaKits starter is ready to operate.

3