Prod Sheet Dual Exterior Hood Installation Kit - Broan

Report 13 Downloads 47 Views
DUAL EXTERIOR HOOD INSTALLATION KIT Part number: VTYIK1

Pressure drops (air intake) 0.25

Inch water gauge

0.20 0.15 0.10 0.05 0.00

0

VG0075A

20

40

60

80

100

120

80

100

120

Airflow (cfm) VR0003

TWO EXTERNAL VENTS IN ONE! Imagine... Only one hole to cut in the exterior wall to perform an outdoor connection for an HRV or ERV. Introducing the simplest way to perform the outdoor connection for units that have a flow rate of less than 110 CFM (0.4 in. w.g.) : the Dual Exterior Hood Kit.

Pressure drops (air exhaust)

• Only one 6” diameter hole in the exterior wall • Aesthetic white polypropylene dual outdoor port

0.25

• Transition fits both 5” or 6” diameter insulated flexible ducts

• Light materials, handy design • Outdoor connection performed in half of the time • Complies with ASHRAE 62.2-2016 The revolutionary design of the Dual Exterior Hood Kit simplifies the installation because there is only one hole to cut in the exterior wall. In fact, every installer knows that locating efficiently one outdoor port is easier (and faster) than locating two. And moreover, there is almost no cross-contamination between the exhaust and intake airflows!

Available at:

Inch water gauge

• Hardware included

0.20 0.15 0.10 0.05 0

0

20

40

60

VG0077A

Airflow (cfm)

Dimensions of the Dual Outdoor Port Backplate

Dimensions of the Dual Outdoor Port

A

B

C

D

A

B

E

F

83/8” (214 mm)

9” (231 mm)

3/4” (19 mm)

3” (76 mm)

83/8” (214 mm)

9” (231 mm)

17/8” (48 mm)

35/8” (92 mm)

E

A

A C

B

VD0048

D VD0047

Dimensions of the Transition 9¾” 248 mm

F

B G

H

6” (152 mm)

20” (508 mm)

G 8¾” 222 mm

H VD0046

VD0118A

Installation

Specifications and ratings

NOTE: Always install the stale air duct from unit on top.

Stale air duct from unit (5” or 6” dia).

• Part number: VTYIK1 • Material for transition: Expanded polystyrene, Grade 54 (building material)

Exhaust stale indoor air, at very high speed

• Material for dual outdoor port: White polypropylene • Contamination rate: 3.2% between stale air to outdoors and fresh air from outdoors

VD0045

Intake of fresh outdoor air, by the bottom of the dual outdoor port

Submitted by: Quantity:

Fresh air duct to unit (5” or 6” dia.)

Exterior wall

Model number:

Date:

Project:

Remarks:

Location: Architect: Engineer: Contractor: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-877-862-7626)

VTYIK1d161108