Product Brochure

Report 10 Downloads 319 Views
Hip

Product Brochure

Dynasty® Acetabular Cup System Design Features 64-68mm 8 Screw Holes Dynasty® Porous-Coated System

Dynasty® Biofoam® System

46-68 in 2mm increments

46-76 in 2mm increments

Metal & Ceramic

Metal & Ceramic

28-46

28-54

Cross-linked Poly

Cross-linked Poly

3

3, 7, 8, 10 Depending on Cup Size

Shell Coating

Porous Beads

Cancellous Titanium

Revision Poly Option

36mm ID from a 52-68mm

36mm ID from a 52-68mm

Shell Sizes Head Options Poly Liner Diameters Bearing Surface Number of Screw Holes

52-62mm 7 Screw Holes

46-68mm 3 Screw Holes

70-76mm 10 Screw Holes

Options for Heads A-Class® Advanced Metal Super Finish CoCr Metal

A-Class® Backfilled Metal

BCH® Ceramic Head Biolox® Delta® Ceramic Head Titanium Sleeve

used with Backfilled Metal & BCH® Ceramic Heads

2

Profemur® Renaissance® Classic Stem Design Features Abbreviated Technique: Ream and Broach Ream to templated size or cortical chatter Sequentially broach with reduced flare broaches to corresponding reamer size

Neck Options Short and long neck lengths, Straight (135º CCD) and Varus 8˚ (127° CCD) neck angles allowing for multiple head center positions to meet range of anatomical needs

Driving Platform Dimple and oval slot designed for unidirectional loading and rotational control during stem insertion, respectively

Lateral Shoulder Rounded lateral shoulder designed to ease stem insertion and minimize risk of fracture

If it is not secure, switch to standard flare broach or ream and broach to larger stem size Implant size and flare corresponding to broach size and flare



Ordering Information Templates

Flare Standard and Reduced flare options designed to maximize metaphyseal fit

Plasma Spray Coating thickness provides 0.5mm (0.25mm per side) additional press-fit

PRNCXR15 (Short Necks) PRNLXR15 (Long Necks)

Surgical Technique

009641

Instruments

PRGIKIT1 (General) PRZNKIT1 (Broaches)

Proximal Taper 3° proximal anterior/posterior taper designed for proximal fill

Surface Roughness Titanium stem surface has glass-beaded texture

PRZNKIT2 (Reamers) PRCLIMPT (Classic Stem Impactor) Implants

Distal Splines Designed to provide additional 1mm press-fit (0.5mm per side) for rotational stability

PRRCKITS (Short Necks) PRRCKITL (Long Necks)

For additional risk information, please consult the Instructions for Use package insert.

Sizes Available in Reduced Flare, sizes 10-16 and Standard Flare, sizes 10-18

Distal Slot Minimizes stem stiffness to discourage fracture during stem insertion

3

Distal Bullet Tip Round distal tip designed to reduce the risk of fracture during insertion and minimize point contact after implantation

Profemur® Gladiator® Plasma Classic Stem Driving Platform Dimpled driving platform for unidirectional loading during stem insertion

Design Features Abbreviated Technique: Broach Only Broach to templated size Implant size corresponding to broach

Ordering Information: Templates PRGLXR15 GLSHXR15 (Gladiator® Bipolar)

Neck Options Medium neck length, Straight (135º CCD) and Varus 8º (127º CCD) neck angles allowing for multiple head center positions to meet range of anatomical needs

Surgical Technique 010845 MH175-606 (Gladiator® Bipolar)

Lateral Shoulder Reduced material helps to conserve bone and ease insertion

Plasma Spray Coating thickness provides 0.5mm (0.25mm per side) additional press-fit

Instruments PRGLKIT3 (core plus Classic metal trial necks) PRGLKIT1 (core plus long and short metal trial

necks, broach handles)

PRGIKIT1

(includes plastic trial heads, broach handles)



GLFLKIT1



(Gladiator® Bipolar)

Implants

PGCLKITP



GLFLKITA



GLFLKITB (femoral heads)

(Gladiator® Bipolar)

For additional risk information, please consult the Instructions for Use package insert.

Macro-Features Vertical grooves are designed for additional rotational stability, while horizontal grooves are designed to evenly distribute load forces Sizes Available in sizes 1-10

Shown with Gladiator® Bipolar Hip System

4

Reduced Tip To minimize point contact in the thigh for comfort

Profemur® TL Classic Stem

Neck Options Short and long neck lengths, straight (135˚ CCD) and varus 8˚ (127˚ CCD) neck angles allowing for multiple head center positions to meet a range of anatomical needs

Design Features

Driving Platform Dimple designed for uni-directional loading during stem insertion and oval slot designed for rotational control during stem insertion

Abbreviated Technique: Broach Only Broach to templated size Implant size corresponding to broach

Lateral Shoulder Reduced material helps to conserve bone and ease insertion

Ordering Information Templates (Short Necks) PTLCXR15 Templates (Long Necks)

PTLLXR15

Surgical Technique

009790

Instrument Kits PRTLKIT2 (broaches and starter reamer) PRGIKIT1

Ti Plasma Spray Designed to provide additional 1mm press-fit (0.5mm per side) to assist initial stability

(includes trial heads/necks)

Implants TLCLKITC For additional risk information, please consult the Instructions for Use package insert. Classic Stem

Impactor

Titanium Stem Surface Glass-beaded texture

Distal Groove Designed to assist rotational stability

Sizes Available in sizes 1-12

Rounded Distal Tip Shape designed to reduce the risk of fracture during insertion and minimize point contact after implantation

5

Profemur® Z Classic and Plasma Z Classic Stems Design Features Driving Platform Dimple designed for uni-directional loading during stem insertion

Abbreviated Technique: Broach-only Broach to templated size Implant size corresponding to broach size Ordering Information Templates

PRFNXR15 (Long Neck Classic)

PRZCXR15 (Short Neck Classic)

Neck Options Include long and short versions with Straight (135˚CCD) and Varus 8˚(127˚CCD) neck angles allowing for multiple head center positions to meet range of anatomical needs

Surgical Technique 010911 Instruments

4251KIT1 (Core plus plastic trial necks, broach handles)



PRZSKIT2



PRGIKIT1



(Includes plastic trial heads, broach handles)



SLBROHAN



Trochanteric Wing Increased trochanteric wing designed to contribute to proximal fill and rotational stability

(In-line broaches)

Plasma Spray Coating thickness of 1mm (0.5mm per side) for additional press-fit

Surface Roughness Titanium stem surface has heavy grit-blast texture (Ra 8μm)

(In-line broach handle)

Implants

PHAZKITA (Long Neck Classic) PHAPKITA (Long Neck Plasma Classic) PZCLKITA (Short Neck Classic) PPZCKITA (Short Neck Plasma Classic) For additional risk information, please consult the Instructions for Use package insert. Classic Stem

Dual Taper Geometry Design intended to provide optimal primary fixation and load transfer



Impactor

Sizes Available in sizes 1-9

Rectangular Cross-Section Provides rotational stability and conserves bone for increased vascularization Rounded Distal Tip Shape designed to reduce risk of fracture during insertion and minimize point contact after implantation

6

Profemur® Preserve Design Features Ordering Information Templates

PPRCXR15

Sizes 1-12 (Classic)

Driving Platform Dimple and oval slot designed for unidirectional loading and rotational control during stem insertion, respectively

Surgical Technique 010439 Instrument Kits

PPREKIT1 (Core) PPREKIT2 (Classic add-on kit) PRGIKIT1 (General)

Implants

PPREKITB (Stems classic)





Lateral Shoulder Reduced material helps to conserve bone and ease insertion

Please consult the Instructions for Use package insert for additional risk information.lassic Stem Impactor

Sizes Available in sizes 1 - 12

Ti Plasma Spray Tapered spray to provide additional 1mm (0.5mm/side) proximal and 0.2mm (0.1mm/ side) distal press-fit to assist initial stability

Surface Grit-blasted design to promote bone apposition and scratch fit

7

EC

MicroPort Orthopedics Inc. 5677 Airline Road Arlington, TN USA 38002 866 872 0211 ortho.microport.com

REP

MicroPort Orthopedics BV Hoogoorddreef 5 1101 BA Amsterdam The Netherlands +31 20 545 01 00

The CE-Marking of Conformity is applied per catalog number and appears on the outer package label, if applicable. Trademarks and Registered marks of Microport Orthopedics Inc. © 2015 MicroPort Orthopedics Inc. All Rights Reserved. 011082