FCC CLASS B COMPLIANCE REPORT
For Electromagnetic Emissions Of
USB3.0 TO DUAL SATA HDD DOCKING
Trade Name Model Number Report Number Date
: : : :
UNITEK Y-3021, Y-3020 SZ1109017-F OCTOBER 12, 2011
Prepared for: TECH-TOP TECHNOLOGY LIMITED ROOM 3, 10/F, BLOCK A, TONIC INDUSTRIAL CENTRE, 26 KAI CHENG ROAD, KOWLOON BAY, HONG KONG
Prepared by:
SEC ENGINEERING SERVICE CO., LTD. 21A, BLDG C. SHENNAN GARDEN, SCIENCE & TECHNOLOGY PARK, NANSHAN, SHENZHEN, GUANGDONG, CHINA TEL: 86-755-86110163 FAX: 86-755-86110248
Report Number: SZ1109017-F October 12, 2011
TABLE OF CONTENTS
1
DECLARATION OF COMPLIANCE ....................................................................................3
2
SYSTEM DESCRIPTION ........................................................................................................4
3
PRODUCT INFORMATION ...................................................................................................4
4
SUPPORT EQUIPMENT .........................................................................................................4
5
FCC (LINE CONDUCTED & RADIATED EMISSION)......................................................5 5.1 LINE CONDUCTED EMISSION TEST PROCEDURE.........................................................5 5.2 RADIATED EMISSION TEST PROCEDURE.......................................................................6 5.3 SUMMARY DATA .................................................................................................................7
6
TEST FACILITY.....................................................................................................................11
7
TEST EQUIPMENT LIST......................................................................................................12
8
BLOCK DIAGRAM OF TEST SETUP.................................................................................13
9
PHOTOGRAPHS ....................................................................................................................14 9.1 PHOTOS OF TEST SETUP...................................................................................................14 9.2 PHOTOS OF EUT..................................................................................................................15
SEC Engineering Service Co., Ltd
Page 2 of 15
Report Number: SZ1109017-F October 12, 2011
1
DECLARATION OF COMPLIANCE
Equipment Under Test:
USB3.0 TO DUAL SATA HDD DOCKING
Trade Name:
UNITEK
Model Number:
Y-3021, Y-3020
Serial Number:
N/A
Applicant:
TECH-TOP TECHNOLOGY LIMITED ROOM 3, 10/F, BLOCK A, TONIC INDUSTRIAL CENTRE, 26 KAI CHENG ROAD, KOWLOON BAY, HONG KONG OCEAN COMPUTER TECHNOLOGY (SHEN ZHEN) CO., LTD BLOCK 1, NO.6 INDUSTRIAL ZONE, YU LV VILLAGE, GONG MING TOWN, BAO’ AN DISTRICT, SHEN ZHEN
Manufacturer:
Type of Test:
FCC Class B
Measurement Procedure:
ANSI C63.4: 2003
File Number:
SZ1109017-F
Date of test:
September 26 ~ October 12, 2011
Deviation:
None
Condition of Test Sample: Normal Test Result:
Passed
The above equipment was tested by SEC Engineering Service Co., Ltd. for compliance with the requirements set forth in the FCC Rules and Regulations Part 15, Subpart B and the measurement procedure according to ANSI C63.4. This said equipment in the configuration described in this report shows the maximum emission levels emanating from equipment are within the compliance requirements. The test results of this report relate only to the tested sample identified in this report.
Approved by Authorized Signatory: Jack/ Manager
SEC Engineering Service Co., Ltd
Page 3 of 15
Report Number: SZ1109017-F October 12, 2011
2
SYSTEM DESCRIPTION
EUT Test Program: 1) 2) 3) 4)
Set up the EUT and connect it to the PC via USB 3.0 ports; The PC was loaded and executed in Windows XP mode; The other related support units worked as usual; Keep the data reading and writing during the test.
3
PRODUCT INFORMATION
Housing Type:
Plastic AC 120V/60Hz Unshielded, 1.2 m
Power during test: Cable: I/O Port of EUT: I/O Port Type AC mains USB 3.0
Q’TY 1 1
Tested with 1 1
Difference between model numbers as below: Item
Model No.
Trade Name
1 2
Y-3021 Y-3020
Unitek Unitek
4
Tested
SUPPORT EQUIPMENT
No.
Equipment
Model #
Serial #
Trade Name
1)
PC
G3S831X
DELL
N/A
Unshielded 1.8m
3)
PS/2 Mouse
M-48a
SZ0204H005 LZE14823966A W
HP
Shielded 1.5m
N/A
4)
PS/2 Keyboard
SK-2502C
C011114546
HP
Shielded 1.8m
N/A
Data Cable Power Cord
Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during emission test. Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended use.
SEC Engineering Service Co., Ltd
Page 4 of 15
Report Number: SZ1109017-F October 12, 2011
5
FCC (LINE CONDUCTED & RADIATED EMISSION)
5.1 LINE CONDUCTED EMISSION TEST PROCEDURE 1)
2) 3) 4)
5) 6)
7)
8) 9)
The equipment was set up as per the test configuration to simulate typical actual usage per the user’s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. Support equipment, if needed, was placed as per ANSI C63.4. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4. The EUT received DC from the PC which received 120VAC/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power source and was grounded to the ground plane. All support equipments received AC power from a second LISN supplying power of 120VAC/60Hz, if any. The EUT test program was started. Emissions were measured on each current carrying line of the EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions. Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. If EUT emission level was less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using an Average detector. Analyzer / Receiver scanned from 150 kHz to 30MHz. The test data of the worst case condition(s) was reported on the Summary Data page. LINE CONDUCTED EMISSION LIMIT
Frequency
Maximum RF Line Voltage QP(Quasi-peak)
AV(Average)
150kHz-500kHz
66-56dBuV
56-46dBuV
500kHz-5MHz
56dBuV
46dBuV
5MHz-30MHz
60dBuV
50dBuV
Note: N/A
SEC Engineering Service Co., Ltd
Page 5 of 15
Report Number: SZ1109017-F October 12, 2011
5.2 RADIATED EMISSION TEST PROCEDURE 1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which is placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. 2) Support equipment, if needed, was placed as per ANSI C63.4. 3) All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4. 4) The EUT received DC from battery. All support equipment received 120VAC/60Hz power from socket under the turntable, if any. 5) The antenna was placed at 3 meters away from the EUT as stated in CISPR 22. The antenna connected to the Analyzer via a cable and at times a pre-amplifier would be used. 6) The Analyzer / Receiver scanned from 30MHz to 1000MHz. Emissions were scanned and measured rotating the EUT to 360 degrees, varying cable placement and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. 7) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization and turntable position were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit and Q.P/Peak reading is presented. 8) The test data of the worst case condition(s) was reported on the Summary Data page. RADIATED EMISSION LIMIT Frequency (MHz)
Distance (m)
Maximum Field Strength Limit (dBuV/m/ Q.P.)
30-88
3
40.00
88-216
3
43.50
216-960
3
46.00
960-1000
3
54.00
SEC Engineering Service Co., Ltd
Page 6 of 15
Report Number: SZ1109017-F October 12, 2011
5.3 SUMMARY DATA CONDUCTION EMISSION Model Number: Y-3021 Tested by: Sammy Test Mode: Working
SEC Engineering Service Co., Ltd
Location: Shielding Room Test Point: Line Detector Function: QP/AV
Page 7 of 15
Report Number: SZ1109017-F October 12, 2011
Model Number: Y-3021 Tested by: Sammy Test Mode: Working
SEC Engineering Service Co., Ltd
Location: Shielding Room Test Point: Neutral Detector Function: QP/AV
Page 8 of 15
Report Number: SZ1109017-F October 12, 2011
RADIATED EMISSION TEST Model Number: Y-3021 Tested by: Tony
Location: Chamber Polar: Horizontal
Test Mode: Working
Detector Function: Peak/QP
SEC Engineering Service Co., Ltd
Page 9 of 15
Report Number: SZ1109017-F October 12, 2011
RADIATED EMISSION TEST Model Number: Y-3021 Tested by: Tony Test Mode: Working
SEC Engineering Service Co., Ltd
Location: Chamber Polar: Vertical Detector Function: Peak/QP
Page 10 of 15
Report Number: SZ1109017-F October 12, 2011
6 Location:
Site Accreditation:
TEST FACILITY
No.1 Workshop, M-10, Middle Section, Science& Technology Park, Shenzhen, China
CNAS: NO. CNAS L2929 NO. CNAS L2929 has been accredited by CNAS for the competence in the field of testing. VCCI: The 3m Semi-anechoic chamber and Shielded Room (7.5m×4.0m×3.0m) have been registered in Accordance with the Regulations for Voluntary Control Measure with Registration No.: R-2197 and C-2383 respectively. Date of Registration: September 29, 2008. Valid until September 28, 2011. FCC-Registration No.: 556682 The Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 556682, June. 27, 2008. Industry Canada (IC) The 3m Semi-anechoic chamber has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1
Instrument Tolerance:
All measuring equipment is in accord with ANSI C63.4 and CISPR 22 requirements that meet industry regulatory agency and accreditation agency requirement.
Ground Plane: Two conductive reference ground planes were used during the Line Conducted Emission, one in vertical and the other in horizontal. The dimensions of these ground planes are as below. The vertical ground plane was placed distancing 40 cm to the rear of the wooden test table on where the EUT and the support equipment were placed during test. The horizontal ground plane projected 50 cm beyond the footprint of the EUT system and distanced 80 cm to the wooden test table. For Radiated Emission Test, one horizontal conductive ground plane extended at least 1m beyond the periphery of the EUT and the largest measuring antenna, and covered the entire area between the EUT and the antenna. It has no holes or gaps having longitudinal dimensions larger than one-tenth of a wavelength at the highest frequency of measurement up to 1GHz.
SEC Engineering Service Co., Ltd
Page 11 of 15
Report Number: SZ1109017-F October 12, 2011
7
TEST EQUIPMENT LIST
For Conducted Emission Test Item
Equipment
Manufacturer
Serial No.
Last Cal.
Cal. Interval
1
L.I.S.N.
ETS-LINDGREN
SEL0021
18-06-2011
17-06-2012
2
EMI Test Receiver
Rohde& Schwarz
SEL0022
18-06-2011
17-06-2012
3
Shielding Room
ZhongYu Electron
SEL0042
N/A
N/A
4
Coaxial Cable
SGS
SEL0024
18-06-2011
17-06-2012
For Radiated Emission Test Item
Equipment
Manufacturer
Serial No.
Last Cal.
Cal. Interval
1
EMI Test Receiver
Rohde&Schwarz
SEL0023
12-12-2010
11-12-2011
2
BiConiLog Antenna ETS-LINDGREN
SEL0014
12-08-2011
11-08-2012
3
Double-ridged horn ETS-LINDGREN
SEL0005
25-12-2010
24-12-2011
SEL0053
18-06-2011
17-06-2012
4
Amplifer
Agilent Technologies
The calibrations of the measuring instruments, including any accessories that may effect such calibration, are checked frequently to assure their accuracy. Adjustments are made and correction factors applied in accordance with instructions contained in the manual for the measuring instrument.
SEC Engineering Service Co., Ltd
Page 12 of 15
Report Number: SZ1109017-F October 12, 2011
8
BLOCK DIAGRAM OF TEST SETUP EUT: USB3.0 TO DUAL SATA HDD DOCKING Trade Name: UNITEK Model Number: Y-3021
Shielding Room Spectrum Analyzer EMI Receiver
LISN
EUT
AC Main
PC
Keyboard
Mouse
Chamber EUT
PC
Keyboard
AC Main
Mouse
Shielding Room
SEC Engineering Service Co., Ltd
Spectrum Analyzer EMI Receiver
Page 13 of 15
Report Number: SZ1109017-F October 12, 2011
9
PHOTOGRAPHS
9.1 PHOTOS OF TEST SETUP RADIATED EMISSION TEST
CONDUCTION EMISSION TEST
SEC Engineering Service Co., Ltd
Page 14 of 15
Report Number: SZ1109017-F October 12, 2011
9.2 PHOTOS OF EUT
SEC Engineering Service Co., Ltd
Page 15 of 15