Protective Cabinet

Report 4 Downloads 139 Views
Protective Cabinet STI-7554, STI-7555 and STI-7555AED

Features · Clear, protective polycarbonate cover with siren/strobe alarm. · Design allows visibility at any angle. · Complete with mounting hardware and gasket. · Includes wire shelf, backing plate and siren/strobe alarm — AED models · External mounting tabs or internal drill dimples. · Cover includes a coated steel internal mounting plate with a baked on white enamel finish. · Siren/strobe alarm lens is red. Also available with amber, green, blue or white lens. · Siren offers 32 user selectable tones. · Alarm can be set for a piercing 100 dB or 85 dB. · Independent strobe and siren timing of 15 seconds, 30 seconds, 60 seconds or continuous. · Powered by a 9 VDC battery or external 12-30 volts. · Low battery indicator.

We protect the things that protect you.® -1-

Table of Contents Warnings..................................................................................................................... page 2 Cleaning Instructions .................................................................................................. page 2 Dimensions.................................................................................................................. page 3 Specifications ............................................................................................................. page 3 Installation of Cabinet ................................................................................................. page 4 Installation of Alarm..................................................................................................... page 4 Alarm Electronic Setup................................................................................................ page 5 Alarm Tones ............................................................................................................... page 5 Alarm Timing and Volume............................................................................................ page 5 Alarm Terminal Strip Connections................................................................................ page 6 Alarm Electronics Assembly......................................................................................... page 6 Assembly Parts List .................................................................................................... page 7 Operation ................................................................................................................... page 7 Warranty...................................................................................................................... page 8 Accessories & Replacement Parts............................................................................... page 8

Warnings

All units are recommended for indoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. When purchasing a siren/ strobe alarm, you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Installer may need to purchase a simple audio-meter, typically 4.31 in. 23.5 in. (109mm) available at your local electronics store, to measure the sound in areas where the alarm is (597mm) expected to be heard during normal noise environment. Results from this test may prove it 16.5 in. 12.2 in. beneficial to purchase additional siren/strobe alarm units. (419mm) (310mm) All specifications and information shown are current as of publication and subject to change 6.44 in. (164mm) 14.2 in. without notice. (360mm)

Cleaning

3/8” DIAMETER

1. Rinse cover with water to remove abrasive dust and dirt. FRONT R.H.NOT SIDESCRUB.) 2. Wash with soap or mild detergent using a soft cloth. (DO 3. Rinse once more, then dry with a soft cloth or chamois. STI-7535AED 4. To remove grease or wet paint, rub gently with a cloth wetted thoroughly with naphtha, then wash and rinse. (DO NOT USE RAZOR BLADES.)

Dimensions

R.H. SIDE

4.31 in. (109mm)

33.75 in. (857mm)

19.75 in. (502mm)

24.75 in. (629mm)

FRONT

3/8” DIAMETER 7.31 in. (186mm)

-2-

R.H. SIDE

Specifications Operating Voltage

Internal power 9 VDC battery (not included)



Remote power 12-30 VDC

OPERATING TEMPERATURE

32°F -120°

Power Consumption

Stand by: 50µA



Siren low volume: 85mA



Siren high volume: 90mA



Strobe: 25mA

Siren Volume

Low: 85 dB



High: 100 dB

Alarm Timing

Independent control for siren and strobe:



15s, 30s, 60s, continuous

Low Battery Warning

LED flash once every 30 seconds

Form C Dry Contacts

0-30VAC/DC, 1 Amp

RATED FOR

Contacts reset after longest alarm setting

Key Switch

Alarm on: normally closed

Alarm Switch

Stand by: normally open contact required

Polycarbonate UL94V-2 Flammability Rating

Installation of Cabinet Note Installation of cabinet should be before installation of alarm because the mounting bracket butts up to cabinet. 1. Insert the (4 or 6) mounting tabs fully into backbox mounting tab slots. Use rubber mallet if necessary.

06298 MOUNTING TABS (6) PROVIDED 19013 SCREW #10 x 1 1/2 in. (6) PROVIDED

2. After selecting a suitable location, place cabinet in closed position, against the wall. Mark and drill (4 or 6) 1/4 in. diameter holes. 04876 Insert the (4 or 6) 19033 anchors. MOUNTING Mount cabinet by driving PLATE in the four or six 07551WR WIRE RACK (INCLUDED WITH #10 x 1 1/2 in. screws. 3. For AED model install shelf, close and lock cabinet.

AED MODEL) 19002 #8-32 x 3/8 in. SCREWS AND (4) 19055 #8-32 KEPS NUTS PROVIDED 19002 SCREW #8-32 x 3/8 in. (4) PROVIDED

OPTIONAL TAB MOUNTING LOCATION

6297550 GASKET 19033 ANCHOR (6) PROVIDED

07550WR WIRE SHELF ON AED MODELS (ADJUSTABLE)

-3-

ROTARY ACTION LATCH (2) PROVIDED SHOWN WITH COVER CLOSED

H

12-24 VDC, 125mA

Installation of Alarm

NC C OM NO

-

Step 1 - Mounting Options To Key Mount Plate or into Wall without Electrical Box OFF

ACTIVE

ON

DRILL 3/16 DIA HOLES

**MAIN POWER CONTROL

NORMALLY OPEN STAND BY

COM

NORMALLY CLOSED

FORM "C" DRY CONTACTS

SUB-SA505 KEY SWITCH MOUNTING ALARM BRACKET SWITCH 18074 SWITCH LOCK

18075 REPLACEMENT #801 KEY

3 9/32 in.

BASE PLATE 19039 SCREW #6 x 1 1/4 in. (2) PROVIDED

19018 ANCHOR #8-10 (2) PROVIDED

+

REMOTE POWER IN 12-24 VDC, 125mA

DC IN

+

-

-

OFF

EY SWK ITCH

ON

A AR M SWLIT CH

**MAIN POWER CONTROL

NC C OM NO

ROUTE THE TWO KEY SWITCH WIRES THROUGH THE HOLE AS SHOWN

NORMALLY OPEN COM

NORMALLY CLOSED ROUTE THE TWO REED ACTIVE FORM "C" SWITCH WIRES FROM ENCLOSURE DRY CONTACTS STAND CABINET THROUGH THE BY HOLE AS SHOWN ALARM SWITCH WIRE ACCESS HOLE

Step 2 - Electronic Setup Select Alarm Tone and Timing Sequence

S1 SIREN

ALARM TONES

S2 LED QTY 10 BATTERY LOW BATTERY INDICATOR LED

ALARM TIMING STROBE TIMING VOLUME ROUTE THE TWO KEY SWITCH WIRES THROUGH THE HOLE AS SHOWN

ROUTE THE TWO REED SWITCH WIRES FROM CABINET THROUGH THE HOLE AS SHOWN BATTERY CABLE WIRE ACCESS HOLE WIRE ENTRY

ENCLOSURE

TERMINAL STRIP

TAMPER SWITCH (REAR VIEW)

Note Select-Alert must be on a flat surface and lens must be installed or the tamper switch will trigger the alarm.

-4+

D

S2

S1

ALARM TIMING

TIMING Step 3 BATTERY - AlarmSTROBE Tones - S1 VOLUME

* 1 2 3 4 5 WIRE ENTRY 6 7 8 9 10 11 12 13 14 15 16

12345 00000 10000 01000 11000 BATTERY CABLE 00100 10100 01100 11100 00010 10010 01010 11010 00110 10110 01110 11110

SIREN

ALARM TONES

ALA

BUZZ SLOW ON/OFF SLOW SIREN 3 BEEP/PAUSE/REPEAT UFO FAST FAST SIREN #5 FAST #2 MEDIUM #5 MEDIUM SWOOP MEDIUM #3 MEDIUM BUZZ TONE STEADY FAST SWOOP SLOW CONTINUOUS FAST REPEAT



LED QTY 10 STRO 12345 V 00001 STANDARD ALARM BATTERY LOW BATTERY 10001 #3 FAST INDICATOR LED 01001 #5 SLOW TERMINAL STRIP BATTERY CAB 11001 FAST BEEP WIRE ENTRY TAMPER00101 SWITCH SOUND A (REAR VIEW) 10101 SOUND B 01101 SOUND C 11101 SOUND D 00011 SOUND D LOUD 10011 SOUND E 01011 SOUND F 11011 SOUND G 00111 SOUND H + DC IN + 10111 #4 LOW REMOTE POWER IN NC CO - OFF ON M N 12-24 01111 VDC, 125mA O SOUND K (OPTIONAL) 11111 MAIN POWER CONTINUOUS FAST NORMALLY OPEN

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Y SWKE ITCH

CONTROL TO KEY SWITCH

COM

ACTIVE REED

Step 4 - Alarm Timing and Volume - S2 ALARM TIMING

1

NORMALLY CLOSED

FORM "C" STAND DRY CONTACTS BY

SWITCH FROM by CABINET Note Sound may be disabled clipping wires to the siren. THIS WILL VOID ALL WARRANTIES. Remove two screws on circuit board; leave enough length of wire to possibly reattach in the future. Then insulate wires to prevent shorting to electronic components.

WIRES TO SIREN

1

A R M SWLA ITCH

2

STROBE TIMING

3

4

VOLUME

5

ON

0 OFF ALARM SIREN STROBE VOLUME TIMING 1 2 3 4 5 15 seconds 1 1 1 1 * High 30 seconds 1 0 1 0 1 60 seconds 0 1 0 1 Low Continuous 0 0 0 0 2 1 = ON 0 = OFF *Factory default settings

-5-

(4) PROVIDED

Step 5 - Electronics Assembly Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 6). Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with tamperproof screw and special. Unit will not operate properly if lens cover is not installed.

ELECTRONICS

TO STI B 05050- LENS COLORS A - AMBER B - BLUE G - GREEN R - RED W - WHITE

INSTALLED BASE PLATE

19011 TAMPER-PROOF SCREW 19016 TAMPER-PROOF TOOL (1) PROVIDED

ROUTE WIRES THRU HOLE WIRE ACCESS HOLE

+

DC IN

+

19002 SCREW #8-32 x 3/8 in. (4) PROVIDED

-

EY SWK ITCH

A R M SWLIA TCH

REMOTE POWER IN 12-24 VDC, 125mA

NC C OM NO

-

NORMALLY OPEN OFF

ACTIVE

ON

**MAIN POWER

STAND BY

NORMALLY CLOSED

FORM "C" DRY CONTACTS

ALARM SWITCH

CONTROL

COM

Step 6 - Terminal Strip Connections

+

REMOTE POWER IN 12-24 VDC, 125mA

+

DC IN

-

-

OFF

EY SWK ITCH

ON

A AR M SWLIT CH

**MAIN POWER

NC C OM NO

NORMALLY OPEN

CONTROL

COM ACTIVE

ALARM SWITCH

NORMALLY CLOSED

FORM "C" STAND DRY CONTACTS BY

-6-

Note “DC IN” are the only polarity sensitive terminals. When external power is used, battery will act as a backup. “Dry Contacts: NC, COM, NO” are used for remote alarm monitoring.

Assembly Parts List SIREN/STROBE ALARM QTY. 1 1 1 2 1 1 4 2 2 1 1

PART # 05000 05050-R 09723 18075 18074 18151 19002 19039 19018 19011 BAT-9VDC

DESCRIPTION Electronics assembly (includes base plate & electronics assembly) Red lens (unless otherwise specified) Key switch mounting bracket #801 key Switch lock N.C. reed switch and magnet (installed in cabinet) Screw #8-32 x 3/8 in. Screw #6 x 1 1/4 in. Anchor #8-10 #8-32 x 1/2 in. tamper screw 9 volt battery

CABINET 1 6 6 6 1 1 1 4 1 1 1 2

07550 06298 19013 19033 07550WR 07551WR 04876 19002 6297550 07503 18050 18054

Hinged polycarbonate enclosure Mounting tabs #10 x 1 1/2 in. screw Plastic anchor Wire shelf (included with AED models only) Wire rack (included with AED models only) Mounting plate #8-32 x 3/8 in. screw Gasket Thumb lock - STI-7555 models Key lock STI-7554 models CH751

}

Step 7 - Operation · Turn key switch onto arm. · Cycle key switch to reset alarm · Alarm will sound when cabinet is opened (alarm switch is electronically closed), alarm cover is removed or unit is removed from the wall. · To service, turn key switch off.

Warnings

Three year guarantee against breakage of polycarbonate housing (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14.

-7-

Accessories and Replacement Parts AED-LBL

Optional AED label - 2 included (applied to sides of cabinet; must be factory installed)

STI-SA5000-R

Replacement Siren/Strobe Alarm

18054

Replacement key for cabinet lock on STI-7554

18075

Replacement key for Siren/Strobe Alarm

07550WR

Wire shelf (included with AED models)

07551WIR

Wire rack (included with AED models)

2306 Airport Rd • Waterford, MI 48327 Phone: 248-673-9898 • Fax: 248-673-1246 [email protected] • www.sti-usa.com

Safety Technology International (Europe) Ltd.

Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 • E-mail: [email protected] • Web: www.sti-europe.com

Printed in USA



Subject to change without notice.

-8-

Inst. 7555AED 2015_05