Specifications Feature

Specification

3.5mm Plug (input) Wiring/ Voltage

Tip: Contact closure control 0-4 VDC Ring: Single-ended mono audio, line level Sleeve: Ground

Screw Terminals Wire size

14-26 AWG (0.5-2.5mm2 ) Solid or Stranded

Audio Output (Screw Terminals)

Voltage: Floating, balanced, Line Level Insertion Loss into 600 Ohms, 0dBm @2kHz: 3dB max

Contact Closure Output (Screw Terminals)

Max Load: 50mA, 60VDC or 42.4VAC peak On-state resistance: 25 Ohms Typical

Power Consumption

0.1 W max

Body Dimensions (LxWxH)

2.07 x 1.58 x 0.87 inches (52.68 x 40.13 x 22.20 mm)

3.5mm Audio Plug Tail Length

11.4 in. (290 mm)

Weight

0.07 lb (0.031 kg)

Humidity

5-90% relative humidity (non-condensing)

Operating Temperature

0-50˚ C

Copyright ©2014 - 2015 ShoreTel, Inc. The ShoreTel logo and ShoreTel are registered trademarks of ShoreTel, Inc. in the United States and/or other countries. All other trademarks, trade names, and service marks herein are the property of their respective owners. PN 800-1913-03

ShoreTel Paging Adapter

Quick Install Guide

960 Stewart Drive Sunnyvale, California 94085 Phone: +1.408.331.3300 OR +1.800.425.9385 Fax: +1.408.331.3333 www.shoretel.com

About the ShoreTel Paging Adapter The ShoreTel Paging Adapter PA-1 provides transformer-coupled line level audio between a ShoreTel Voice Switch and a paging system. The ShoreTel Paging Adapter mitigates 50/60Hz and ground noise found in some paging installations. The ShoreTel Paging Adapter is compatible with all ShoreTel switches with paging ports. The ShoreTel Paging Adapter also includes a solid-state, contact closure relay output. The normally open relay provides optional keying to contact-closure capable paging systems. The contact closure feature is supported by ShoreTel ST model voice switches.

ST200/ST500 ST24A/ST48A 3. To enable the contact closure for a Voice Switch, navigate to Administration > Appliances/Servers > Platform Equipment in ShoreTel Director, select the Voice Switch, click the Switch tab, and select Enable contact closure for paging. 4. Insert the paging adapter 3.5mm audio plug into the ShoreTel Voice Switch paging port. • •

Installation Equipment To install the ShoreTel Paging Adapter, you need the following equipment: • 1/8-inch (3.1 mm) Slotted screwdriver

Connecting the ShoreTel Paging Adapter

1. Connect audio conductors from the paging adapter

audio out screw terminals to the paging system 600 Ohm audio input page port terminals. Use twistedpair audio conductors to minimize electromagnetic noise pickup. 2. (Optional) Connect the paging adapter contact closure screw terminals to the paging system contact closure wiring. The contact closure feature is supported for the following ShoreTel Switches: • ST1D/ST2D • ST50A/ST100A/ST100DA

Audio out screw terminals

Contact closure screw terminals

Warranty and Limitation of Liability Refer to www.shoretel.com/about/warranty.html for details on ShoreTel’s warranty policy.