7 Click Supported Models. Select models from the list and click OK.
RANADVISOR TRUESITE MATRIX QUICK START GUIDE
CONFIGURING RANADVISOR TRUESITE CONTROLLER
8 Click Sequencer Test and select a sequencer file from the list.
If you are using RANAdvisor TrueSite Controller for the first time, configure the settings as shown below before performing any operations such as indoor navigation, recording and running a sequencer test.
9 Click Default Display Measurements and select parameters from the list. You can select up to eight parameters from the list to be reported back to the tablet during collection. When finished, press OK at the bottom. 10 Select the Save icon on the top right corner of the Phone Configuration screen.
OVERVIEW
A.
RANAdvisor TrueSite Matrix helps you analyze multiple network technologies using a master/slave mode. The master tablet can control and receive measurements from multiple slave devices running TrueSite PRO. The application allows you to connect a tablet with six slave devices and one receiver. You must have appropriate licenses to use the RANAdvisor TrueSite Controller.
11 After creating a phone configuration, perform step D as shown below.
Setting up your Master and Slave Connections
1 Power on the master tablet and slave devices.
D.
2 Go to the device Settings on the master tablet and slave devices. For example, on the Google
1 Launch RANAdvisor TrueSite on the master tablet. 2 Select Controller.
Nexus 10 tablet, you will see the Settings icon as 3 Enable Bluetooth on the master and slave devices.
FEATURES
Ultra-portable with an intuitive user interface
Tablet app controls up to six devices and one receiver
Bluetooth connectivity eliminates cables
Identifies missing/faulty antennas and macro-ingress issues during collection
Fully iBwave design compatible; floor plans can be added as picture files
Covers LTE, WCDMA, GSM,CDMA, and EV-DOM
Importing an Indoor Map
3 Tap the Main Menu icon
4 Select Bluetooth and enable Visible to all nearby Bluetooth devices on the master tablet and slave devices.
on the Controller screen.
4 Select Configuration Settings > Test Configurations > Indoor Maps.
5 On the master tablet Bluetooth screen, under AVAILABLE DEVICES, select a device to pair.
5 Tap the Import icon
6 Click Pair/OK when you receive a prompt on the master tablet and slave device Settings screen. After pairing the devices, you will see it listed under Paired devices on the master tablet.
.
6 Select an iBwave file from the device storage. The application imports all the floor plans and antennas included in the iBwave map file. 7 Click the back button until you reach the Controller screen. 8 Select the MAPS tab.
7 Go to the device Apps and launch RANAdvisor TrueSite slave devices.
KEY BENEFITS
Helps quickly deploy and troubleshoot small cells and DAS
Tests faster with real-time problem resolution
Enables unobtrusive, discreet testing
Minimizes repeat data capture walks
on the master tablet and 9 Select the Main menu icon
.
8 From the TrueSite Home screen, go to Settings > General and select Automation Control Mode on the master tablet and slave devices.
10 Select Choose Indoor Map.
9 From the Automation Control Options, select Local Bluetooth Control on the master tablet and slave devices.
12 Select a floor plan from the list. The application will perform Geo-Referencing if it is loaded for the first time.
10 By default, you will see the tablet configured as Master. For other devices, you must configure it as Slave. After enabling the local Bluetooth control, you will see the Controller screen on the master tablet.
13 After selecting a floor plan, perform step E as shown below.
11 Select an iBwave file from the list.
E.
11 On the master tablet Controller screen, under Bluetooth, select Paired Devices. This displays a list of slave devices with a Bluetooth address and device name.
Applying a Phone Configuration
1 Launch RANAdvisor TrueSite on the master tablet.
12 Select a slave device from the list to connect with the master tablet. Make sure the Bluetooth address and the device name matches with the slave device you are connecting.
2 Select Controller. 3 Select a device under Connected.
13 Click Connect on prompt. When a device is connected with the master, you will see it listed under Connected.
4 Select the Configure icon
on the top right corner of the screen.
14 After setting up master and slave devices, perform step B as shown below. 5 Select the Folder icon
B.
Loading a Test Sequence
on the top right corner of the screen.
6 Select a phone configuration to apply from the list.
1 Launch RANAdvisor TrueSite on the master tablet.
7 Click OK when you receive a prompt to apply the configuration. After applying the
2 Select Controller.
configuration, you will see a green indicator
beside the selected device.
8 After applying a phone configuration, perform step F as shown below. 3 Tap the Main Menu icon
on the Controller screen.
4 Select Configuration Settings > Test Configurations > Test Sequences.
F.
5 Click Tap here to Create or Load a Test Sequence.
Starting/Stopping a Recording
1 Launch RANAdvisor TrueSite on the master tablet.
6 Select Load option.
2 Select Controller.
7 Select a Test Sequencer XML file from the list. 8 After loading a Test Sequencer file, perform step C as shown below.
C.
3 Tap the Main Menu icon
on the Controller screen.
4 Select Create A New Job. Enter a name to identify the job.
Creating a Phone Configuration
5 Click Start Recording Now. You will see a recording indicator
beside the device.
6 To stop recording, select the Main menu icon and click End Current Job. The recording will stop on all the slave devices.
1 Launch RANAdvisor TrueSite on the master tablet. 2 Select Controller. 3 Tap the Main Menu icon
on the Controller screen.
4 Select Configuration Settings > Test Configurations > Phone Configurations. 5 Click the + icon on the top right of the Phone Configuration screen to add a phone configuration. 6 Click Name. Enter a name and description to identify the phone configuration, and click OK. Quick Start Guide – April 2016
1
Quick Start Guide – April 2016
2
Quick Start Guide – April 2016
3
CONFIGURING TRUESITE CONTROLLER SETTINGS
INTERACTING WITH TRUESITE CONTROLLER
TECHNICAL ASSISTANCE If you require technical assistance, call 1-844-GO-VIAVI (1-844-468-4284). For the latest TAC information, go to http://www.viavisolutions.com/en/services-and-support/support/technicalassistance or email
[email protected].
Configure Settings
Start
Connect Devices / Receiver Enable Bluetooth on all Devices Apply Settings to Devices/ Receiver Pair Devices
Prepare for Data Collection
Define Master/Slave
Load Planned Route/ Point to Location
Connect Master/Slave
Go to Test Configurations
1. 2. 3.
Click the Controller Main Menu icon. Click Configuration Settings. Click Test Configurations in the left panel.
1. 2.
Click the + icon on the top right. Click Tap here to Create or Load a Test Sequence. Add the required tests. Click the test sequencer blue bar and select Save.
Define Test Sequencer 3. 4.
Create Phone Configuration
1. 2. 3. 4.
Enter a phone configuration name. Select supported models. Select a sequencer test. Select up to 8 parameters for collection.
1.
Copy the ibwc files to the device storage /FTA/IBWave folder. Click the import icon on the top right. Select the ibwc files.
Create a New Job
Save for Later Start Recording Now
Select a Job / My Jobs
Replay the Job Import Indoor Maps
Load Indoor Map
2. 3.
Do the Job Again
Record the Walk / Drive State
Stop Recording/Playback Configuration Complete
Quick Start Guide – April 2016
4
Quick Start Guide – April 2016
5
Quick Start Guide – April 2016
6