GeneralNotes 

 REFLEXLightinghaspreparedthismanualtoassistyouandyourclientsintakingadvantageof availableutilityincentiveprograms. The enclosed Product Selection Guide includes fixtures that apply to local prescriptive utility incentiveprograms.Useofproductsindicateddoesnotguaranteeanincentive.Pleasecontact yourlocalutilityrepresentativeand/orREFLEXLightingforanyspecificquestionsorconcerns pertainingtoyourspecificproject.Otherproducts,inadditiontothoselisted,maybeeligible forincentives,pleasecontactyourREFLEXrepresentativeforassistance. We also encourage you to visit the REFLEX website for updated Energy Services information regardingnewproducts,linkstoapplicationformsandimportantinformationalsites,beneficial energyanalysistools,etc.Pleasevisitusatwww.reflexlighting.com.

 

         

REFLEXLighting 

7TideStreetBoston,MA02210  PrintedMay2011 1

Understanding&UtilizingPowerCompanyRebates 

• IdentifyUtilitybasedonprojectlocation: Where?

• Massachusetts EnsurethatprojectfallswithinMassSaveProgram AdministratorTerritory(CapeLightCompact,NationalGrid,NSTAR,Unitil, WesternMassElectric) • RhodeIsland NationalGrid

• DetermineifprojectisconsideredRetrofitor NewConstruction/MajorRenovation Which?

What?

• Selectappropriatefixturesandcontrolsfromprovided ProductSelectionGuide

• Download,CompleteandSubmitApplicationtoUtility How?



*Itisveryimportanttoinvolvetheutilityearlyoninyourprojectasprogramsare continuallyevolvingwithnewtechnology!Workwiththeappropriateprogram  administratortoconfirmavailableincentiveprograms,gainpreapprovalfor productsusedandverifytotalprojectincentive$value!



NeedaQuotation?





[email protected]OR   FAXto(617)2699443“Attn:ENERGY”   x Includespecificballastcatalognumbers (ifrequired) x DistributortoconfirmaccuracyofBOM 

NeedaLayout? [email protected]OR FAXto(617)2699443“Attn:ENERGY” x x x x x x

Includeroomdimensions(Length,Width,Height) Mountingheightoffixtureabovefinishedfloor Is it a one for one retrofit (include existing fixture typesandspacing)ornewinstallation? LightLevelPlane(2.5’AFF,floor,other)? FootcandleRequirements RoomConditions/Reflectances o Clean(Office)–80/50/20 o Medium(LightCommercial)–70/30/20 o Dirty(HeavyIndustrial)–50/30/10 2

ASimpleWattsperSquareFootCalculation 

(InputWattsperFixture)x(NumberofFixtures)=Wattspersquarefoot (RoomLength)x(RoomWidth)





 

TypicalCommercialOfficeSpaceExample 72’x72’officewithfixturesspaced8’x10’oncenter  EXISTING: 3lamp/18cellparabolicfixturewith(3)standardT8lampsandelectronicballast(88inputwatts) 

(65)x(88)=5720=1.10Wattspersquarefoot (72)x(72)5184 











PROPOSEDENERGYSAVINGALTERNATIVE: 2lamp/12cellparabolicfixturewith(2)HPT8lampsandNEMAPremiumballast(Normal.88BallastFactor)  (65)x(53)=3445=.66Wattspersquarefoot   (72)x(72)5184  

ThisSolutionProvides: x x x x x

ReductioninW/sqft.from1.10to.66 40%Energysavings 41averagemaintainedfootcandles(IESrecommends3035footcandlesforofficelighting) PotentialPerformancerebatetotheowner EligibilityforanEPActtaxdeduction

LightingPowerDensityLimits BuildingAreaType AutomotiveFacility Gymnasium ManufacturingFacility Office ParkingGarage Retail School/University Warehouse

LPD (W/ft2) 0.9 1.1 1.3 1.0 0.3 1.5 1.2 0.8

*AboveLPDlimitsobtainedfromChapter13Table1308.6.2.1,fortheBuildingAreaMethod.Youmay alsoreferenceChapter13Table1308.6.2.2fortheSpacebySpacemethodandcorrespondingLPD limits.   3

EPAct2005AcceleratedTaxDeduction Whyshouldyoucare? TheEnergyPolicyActof2005createdtheEnergyEfficientCommercialBuildingsTaxDeduction(CBTD) whichincludesanacceleratedtaxdeductiondesignedtoreducetheinitialcostofinvestinginenergy efficientlightingandotherbuildingsystems.Inshort,withtheCBTD,thecostofnewlightingorother buildingsystemscanbeclaimedinasingletaxyearinsteadofamortizedoveraperiodofyears.Thisis especiallybeneficialinourlocalmarketbecausewearegovernedbyastricterbuildingcodeand reducedLPDlimits.

Whatdoyouneedtoknow? x x x x x

FederalGovernmentextendedthroughDecember2013 Bilevelswitchingrequiredinalloccupanciesexcept: o Hotelguestrooms,storerooms,restrooms,publiclobbies MinimumIESNArecommendedlightlevelsmustbeachieved Lightingsystemsmustbecapitalexpendituresthatarenormallydepreciated (simplelampreplacementsdonotqualify) Thetotalamountthatcanbedeductediscappedatbetween$0.30and$0.60/sq.ft.onthe belowslidingscalebasedona2540%reductionbelowthemaximumallowablelighting powerdensityinASHRAE/IESNA90.12001:  ASHRAE/IESNA90.12001LPDLimits  (Watts/sq.ft.)

LPD Reduction 0% 25% 30% 35% 40% 45% 50%

Office 1.3 0.975 0.910 0.845 0.780 0.715 0.650

School/ University 1.5 1.125 1.050 0.975 0.900 0.825 0.750

Retail

Warehouse

1.9 1.425 1.330 1.235 1.140 1.045 0.950

1.2 0.900 0.840 0.780 0.720 0.660 0.600

TaxDeduction  InterimLightingRules Non Warehouse $0.00 $0.30 $0.40 $0.50 $0.60 $0.60 $0.60

Warehouse $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.60



Whocantakeadvantage? x x x x

CommercialBuildingownersgetthedeductionfordepreciableproperty(June2,2006IRSclarification) Publicownedbuildingthedesigner(s)ofthesystemcanclaimthetaxdeduction Tenantsmaybeeligibleforthetaxdeductioniftheycarrythelightingfixturesasanasset(retailstores) Independentcertificationbya“qualified”individualisrequired

AboveinformationtakenfromtheCommercialLightingTaxDeductionwebsite. Pleasevisitforadditionalinformation–http://lightingtaxdeduction.org 4

PRODUCTSELECTIONGUIDE NEWCONSTRUCTIONINCENTIVES RETROFITINCENTIVES

CODE10HighPerformanceorReducedWattageLamp&BallastSystem(4'T8or4'T5) AnynewfluorescentfixturewithHighPerformance/ReducedWattage(HP/RW)4'T8or4'T5lampsandelectronicballast.Eachnewfixtureiscomposedofaballastand1, 2,3or4lamps.Onlyoneincentivemaybecountedperfixture.Multiplefixturesservedbyasingleballastareonlyeligibleforoneincentive.

CODE30AHighEfficiency2LampPrismaticLensedFluorescentFixture(2x2or2x4) CODE30AHighEfficiency2LampPrismaticLensedFluorescentFixture(2x2or2x4) MinimumWattsSaved=27W MANUF. MANUF METALUX METALUX

CATALOG# CATALOG # 2GC8232AUNVHB81 2GC8217AUNVEB81

DESCRIPTION 2X42HPT8LensedTroffer 2X22T8LensedTroffer

EFFICIENCY 84.6% 76.9%

CODE30BHighEfficiency2LampParabolicFluorescentFixture(2x2or2x4) CODE30BHighEfficiency2LampParabolicFluorescentFixture(2x2or2x4) MinimumWattsSaved=27W MANUF. METALUX METALUX METALUX METALUX METALUX METALUX

CATALOG# 2P2GX217S24MIUNVEB81PAF 2HP2GX232S26IUNVHB81 2HP2GX217W23PUNVEB81 2HP2GX232W26PUNVHB81 2OPG217FB23WUNVEB81 2OPG232FB26WUNVHB81

DESCRIPTION 2X22T88CellSilverParabolic 2X42HPT812CellSilverParabolic 2X22T86CellWhiteParabolic 2X42HPT812CellWhiteParabolic 2X22T8OPTICA6CellWhiteParabolicwithTannenbaumLouvers 2X42HPT8OPTICA12CellWhiteParabolicwithTannenbaumLouvers

HPT8:QualifyingHighPerformanceT8lampsmustbeinstalledinfixturetoqualifyforincentive. HB81andUHB:IndicatethatqualifyingNEMAPremiumHighEfficiencyT8ballastwillbeinstalledinfixtureatfactory.

EFFICIENCY 80.9% 80.5% 81.9% 84.8% 82.5% 87.1%

5

PRODUCTSELECTIONGUIDE NEWCONSTRUCTIONINCENTIVES RETROFITINCENTIVES

CODE30CHighEfficiency2LampRecessedIndirect/DirectFluorescentFixture(2x2or2x4) CODE30CHighEfficiency2LampRecessedIndirect/DirectFluorescentFixture(2x2or2x4) MinimumWattsSaved=27W MANUF. METALUX METALUX METALUX METALUX METALUX NEORAY NEORAY

CATALOG# 2RDI232FLSUNVHB81 2RDI217FLSUNVEB81 2RDI228T5RPUNVEBT1 2RDI214T5RPUNVEBT1 2RDI224T5RPUNVEBT1 274R2T5ETGUEBSI 272R2T5HOETGUEBSI

DESCRIPTION 2x42HPT8OVATIONRecessedIndirect/DirectwithFLSLens 2X22T8OVATIONRecessedIndirect/DirectwithFLSLens 2X42T5OVATIONRecessedIndirect/DirectwithCenterPerfBasket 2X22T5OVATIONRecessedIndirect/DirectwithCenterPerfBasket 2X22T5HOOVATIONRecessedIndirect/DirectwithCenterPerfBasket 2X42T5FENESTRARecessedIndirect/DirectwithCenterPerfBasket 2X22T5HOFENESTRARecessedIndirect/DirectwithCenterPerfBasket

EFFICIENCY 82.0% 80.4% 76.9% 73.3% 73.3% 81.1% 81.5%

CODE31HighEfficiency3LampFluorescentFixture(2x4) CODE31HighEfficiency3LampFluorescentFixture(2x4) MinimumWattsSaved=31W MANUF. CATALOG# DESCRIPTION METALUX 2GC8332AUNVHB81L 2X43HPT8LensedTroffer METALUX 2HP3GX332S36IUNVHB81L 2X43HPT818CellSilverParabolic METALUX 2RDI332FLSUNVHB81L 2x43HPT8OVATIONRecessedIndirect/DirectwithFLSLens *Eligiblefixturesarelimitedto3lampswithalowpowerballastfactor250sqft.

CODE64BWallMountedVacancyOccupancySensors(Minimum51WControlled)* CODE64BWallMountedVacancyOccupancySensors(Minimum51WControlled)* MANUF. CATALOG# DESCRIPTION COOPER VNLWP1001MVN PassiveInfraredTech./Singlecircuit/(120/277)WallSwitchVacancysensor *SensorsmustoperateasManualON,AutomaticOFF.Noteligibleifinstalledinrestrooms,lockerrooms,stairwellsorrooms>250sqft.

CODE65PhotocellSensors(Minimum70WControlled)* CODE65PhotocellSensors(Minimum70WControlled)* MANUF. CATALOG# DESCRIPTION StandalonePhotocellSensor(canbeconnectedtoupto50ballasts) GREENGATE DLCPDDIM *Photocellcontrolforlightingsystemsthatoperateon24hoursaday,7daysaweek(8,760hoursannually).

CODE68HighBayFluorescentOccupancyControlSystems(Minimum110WControlledperFixture)* CODE68HighBayFluorescentOccupancyControlSystems(Minimum110WControlledperFixture)* MANUF.

CATALOG#

DESCRIPTION

HighBayFixtureMountOccupancySensor,360andAisleway(360degreelensandAislewaylensincluded), PassiveInfraredTechnology,800VA6.67A@120VAC5060Hz,1200VA4.33A@277VAC5060Hz,1500VA 4.32A@347VAC5060Hz,120/277/347vac,CommercialGradeWhiteCaliforniaTitle24Compliant. HighBayFixtureMountOccupancySensor360degree,PassiveInfraredTechnology,800VA@120VAC, COOPER OEFP 1200VA@277VAC *Ballastsmustbeautomaticallycontrolledbasedonoccupancy.Systemswithmanual"ON"oroverrideswitchesarenoteligible.Sensorsmaybemountedonindividual fixturesonly. LEVITON

OSFHUITW

14

PRODUCTSELECTIONGUIDE NEWCONSTRUCTIONINCENTIVES RETROFITINCENTIVES PleasenotethatLEDproductsmustbeapprovedbytheappropriateentitytoqualifyforutilityincentives.PleasecontactReflexforcurrentlistingofapprovedproducts underEnergyStarandDesignLightsConsortium(DLC)asproductsarecontinuallybeingevaluatedforapprovalandaddedtotheselists.

CODE80LEDDownlightFixtures(EnergyStarRated&HardwiredorGU24base)* CODE80LEDDownlightFixtures(EnergyStarRated&HardwiredorGU24base)* MinimumWattsSaved=25W MANUF. HALO HALO HALO HALO PORTFOLIO PORTFOLIO PORTFOLIO PORTFOLIO

CATALOG# H455TUNVD010EL405830TL402WHS H750TML706830493WBS06 H750TML709830ICAT120D493WBS06 H750TD010ML712830TUNVD010493WBS06 LD409835D1204LS50LI LD413835D0104LS50LI LD610835D1206LS50LI LD615835D0106LS50LI

DESCRIPTION 4"550LumenEnergyStarDownlightwithSoliteRegressedLens&WhiteReflector,3000K 6"600LumenEnergyStarDownlightwithSoliteRegressedLens&WhiteBaffle,3000K 6"900LumenEnergyStarDownlightwithSoliteRegressedLens&WhiteBaffle,3000K 6"1200LumenEnergyStarDownlightwithSoliteRegressedLens&WhiteBaffle,3000K 4"900LumenEnergyStarDownlightwithSpecularClearReflector,3500K 4"1300LumenEnergyStarDownlightwithSpecularClearReflector,3500K 6"1000LumenEnergyStarDownlightwithSpecularClearReflector,3500K 6"1500LumenEnergyStarDownlightwithSpecularClearReflector,3500K

PleaseaskyourReflexRepresentativeforotheravailabletrimoptions,LEDcolortempsandfixturesthatmeetEnergyStarcriteria.

*EligiblefixturesmustbelistedasCommercialLEDbyEnergyStar.

CODE81AIntegralLEDDirectionalReplacementLamps(MR16,PAR16&PAR20)* MinimumWattsSaved=12W MANUF. CATALOG# DESCRIPTION LEDMR16HOReplacementLamp,2700K,Spot(15deg)BeamSpread,6.5W NEXXUSARRAY AACMMR162715 LEDMR16HOReplacementLamp,2700K,NarrowFlood(25deg)BeamSpread,6.5W NEXXUSARRAY AACMMR162725 LEDMR16HOReplacementLamp,3000K,Spot(15deg)BeamSpread,6.5W NEXXUSARRAY AACMMR163015 LEDMR16HOReplacementLamp,5000K,NarrowFlood(25deg)BeamSpread,6.5W NEXXUSARRAY AACMMR165025 *EligiblelampsarerequiredtobelistedbyEnergyStarorMassSaveInterimLEDPreQualifiedlist.

15

PRODUCTSELECTIONGUIDE NEWCONSTRUCTIONINCENTIVES RETROFITINCENTIVES

CODE81BIntegralLEDDirectionalReplacementLamps(PAR30&PAR38) &ScrewBaseLEDDownlightRetrofitKits* MinimumWattsSaved=25W MANUF. NEXXUSARRAY NEXXUSARRAY ALLPRO HALO HALO HALO

CATALOG# AE26PAR38183010 AE26PAR38183025 RL706830E26WBS ML706830493WBS06 ML709830ICAT120D493WBS06 ML712830TUNVD010493WBS06

DESCRIPTION LEDPAR38ReplacementLamp,3000K,Spot(10deg)BeamSpread,18W LEDPAR38ReplacementLamp,3000K,NarrowFlood(25deg)BeamSpread,18W 6"600LumenEnergyStarDownlightRetrofitKit,WhiteBaffle,3000K 6"600LumenEnergyStarDownlightRetrofitKitwithSoliteRegressedLens&WhiteBaffle,3000K 6"900LumenEnergyStarDownlightRetrofitKitwithSoliteRegressedLens&WhiteBaffle,3000K 6"1200LumenEnergyStarDownlightRetrofitKitwithSoliteRegressedLens&WhiteBaffle,3000K

PleaseaskyourReflexRepresentativeforotheravailabletrimoptions,LEDcolortempsandfixturesthatmeetEnergyStarcriteria.

*EligiblelampsarerequiredtobelistedbyEnergyStarorMassSaveInterimLEDPreQualifiedlist.

CODE82ALEDCooler,FreezerCaseorRefrigeratedShelvingFixtures(3'&4'Length)* CODE82ALEDCooler,FreezerCaseorRefrigeratedShelvingFixtures(3'&4'Length)* MinimumWattsSaved=14W MANUF. ElectraLED ElectraLED ElectraLED ElectraLED ElectraLED

CATALOG# ELS42DR4R1N ELS43DR4R1N ELS44DR4R2N ELS45DR4R2N ELS46DR4R3N

DESCRIPTION 4'2DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 4'3DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 4'4DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 4'5DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 4'6DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) Alsoavailablein35Kand/orwithdimming.

*EligiblefixturesarerequiredtobelistedbyMassSaveInterimLEDPreQualifiedlistorDesignLightsConsortium.

CODE82BLEDCooler,FreezerCaseorRefrigeratedShelvingFixtures(5'&6'Length)* CODE82BLEDCooler,FreezerCaseorRefrigeratedShelvingFixtures(5'&6'Length)* MinimumWattsSaved=23W MANUF. ElectraLED ElectraLED ElectraLED ElectraLED ElectraLED ElectraLED ElectraLED ElectraLED ElectraLED ElectraLED

CATALOG# ELS52DR4R1N ELS53DR4R1N ELS54DR4R2N ELS55DR4R2N ELS56DR4R3N ELS62DR4R1N ELS63DR4R1N ELS64DR4R2N ELS65DR4R2N ELS66DR4R3N

DESCRIPTION 5'2DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 5'3DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 5'4DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 5'5DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 5'6DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 6'2DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 6'3DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 6'4DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 6'5DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) 6'6DoorLEDFreezerCaseKitincludingallpowersupplies,accessories,etc.(42K) Alsoavailablein35Kand/orwithdimming.

*EligiblefixturesarerequiredtobelistedbyMassSaveInterimLEDPreQualifiedlistorDesignLightsConsortium.

16

PRODUCTSELECTIONGUIDE NEWCONSTRUCTIONINCENTIVES RETROFITINCENTIVES

CODE83LEDLowBayFixtures(Garage&Canopy)* CODE83LEDLowBayFixtures(Garage&Canopy)* MinimumWattsSaved=60W MANUF.

CATALOG# DESCRIPTION VPLA02LEDE1SQ ValetGarageFixturewith2LightBarsandTypeVSquareDistribution,4000K,>70CRI,53W VPLA03LEDE1SQ ValetGarageFixturewith3LightBarsandTypeVSquareDistribution,4000K,>70CRI,80W VPLA04LEDE1RW ValetGarageFixturewith4LightBarsandRectangularWideDistribution,4000K,>70CRI,104W VPLA04LEDE1SQ ValetGarageFixturewith4LightBarsandTypeVSquareDistribution,4000K,>70CRI,104W *Eligiblefixturesarerequiredtobeinstalledin8,760hourapplicationsandlistedbyMassSaveInterimLEDPreQualifiedlistorDesignLightsConsortium. McGRAWEDISON McGRAWEDISON McGRAWEDISON McGRAWEDISON

CODE84LEDTrackHeads(Hardwired)* MANUF. HALO HALO HALO HALO HALO HALO AMERLUX AMERLUX

CATALOG# L805SMLSP830 L805SMLNF830 L805SMLFL830 L805MEDSP830 L805MEDNF830 L805MEDFL830 CNTRV3324LEDEWTTN3120NF3000 CNTRV3432LEDEWT120NF3000

DESCRIPTION STASISSMALLLEDTrackheadwithSpotDistribution,3000K(alsoavailable4000K) STASISSMALLLEDTrackheadwithNarrowFloodDistribution,3000K(alsoavailable4000K) STASISSMALLLEDTrackheadwithFloodDistribution,3000K(alsoavailable4000K) STASISMEDIUMLEDTrackheadwithSpotDistribution,3000K(alsoavailable4000K) STASISMEDIUMLEDTrackheadwithNarrowFloodDistribution,3000K(alsoavailable4000K) STASISMEDIUMLEDTrackheadwithFloodDistribution,3000K(alsoavailable4000K) Contour3x3TrackheadwithNarrowFloodDistribution,3000K Contour3x4TrackheadwithNarrowFloodDistribution,3000K

AskyourReflexRepresentativeforothervariationsofaboveproductthatareapproved.

*Replacementlampsnoteligible.EligiblefixturesarerequiredtobelistedbyMassSaveInterimLEDPreQualifiedlistorDesignLightsConsortium.

17

PRODUCTSELECTIONGUIDE NEWCONSTRUCTIONINCENTIVES RETROFITINCENTIVES ThedevelopmentofstandardsforLEDsisconstantlyevolvingwithcontinuousupdatesandadditionstobothEnergyStarandDesignLightsConsortiumQualifiedProduct Lists.BelowrepresentsalistofproductsontheDLCQualifiedProductsListatthetimeofprintingofthismanual.PleasenotethatEnergyStarorDesignLightsConsortium approvaldoesnotguaranteeanincentive,eachopportunityisevaluatedonacustombasisperproject. PleasecontactReflexforcurrentlistingofApprovedLEDproductsthatmaybeeligibleforcustomincentives.

OUTDOORPOLE/ARMMOUNTEDAREA&ROADWAYLUMINAIRES MANUF. McGRAWEDISON McGRAWEDISON McGRAWEDISON McGRAWEDISON McGRAWEDISON McGRAWEDISON McGRAWEDISON

CATALOG# VTSA05LEDE1SL4 VTSA06LEDE1T3 VTSA06LED480T3 VTSA09LEDE1SL3 VTSA09LEDE1SL4 VTSA09LEDE1T4 VTSA12LEDE1T3

DESCRIPTION VentusSiteFixturewith5LightBarsandTypeIVDistribution&SpillControl,4000K,>70CRI,129W VentusSiteFixturewith6LightBarsandTypeIIIDistribution,4000K,>70CRI,156W VentusSiteFixturewith6LightBarsandTypeIIIDistribution,4000K,>70CRI,156W VentusSiteFixturewith9LightBarsandTypeIIIDistribution&SpillControl,4000K,>70CRI,232W VentusSiteFixturewith9LightBarsandTypeIVDistribution&SpillControl,4000K,>70CRI,232W VentusSiteFixturewith9LightBarsandTypeIVDistribution,4000K,>70CRI,232W VentusSiteFixturewith12LightBarsandTypeIIIDistribution,4000K,>70CRI,309W

OUTDOORWALLMOUNTEDAREALUMINAIRES MANUF.

CATALOG#

McGRAWEDISON ISTA02LEDE1BL3

DESCRIPTION ImpactWallPackwith2LightBarsandTypeIIIDistributionw/BackLightControl,4000K,>70CRI,53W

HIGHBAY&LOWBAYFIXTURESFORCOMMERCIAL/INDUSTRIALBUILDINGS MANUF. LIGHTWILD LIGHTWILD LIGHTWILD LIGHTWILD LIGHTWILD

CATALOG# LWLUSIOLBAYMX2X2HONWXXX LWLUSIOLBAYWX2X2HONWXXX LWLUSIOHBAYX2X2HONWXXX LWLUSIOHBAYNX2X2HONWXXX LWLUSIOALX2X2HONWXXX

DESCRIPTION LUSIOLowbay,MediumBeamSpread,2x2,HighOutput,4000K,180W LUSIOLowbay,WideBeamSpread,2x2,HighOutput,4000K,180W LUSIOHighbay,2x2,HighOutput,4000K,180W LUSIOHighbay,NarrowBeamSpread,2x2,HighOutput,4000K,180W LUSIOAisleLighter,2x2,HighOutput,4000K,180W

LINEARPANELS(2X2TROFFER) MANUF. FAWOO

CATALOG# LSL22/1045R1

DESCRIPTION Lumisheet1.0,2X2ZeroPlenumTroffer,4100K,50W(LSLA600H)

18

SpecificationIncentivePrograms InadditiontotheNewConstructionPrescriptiveincentiveprogram,wewelcometheopportunityto workwithourspecifierpartnersindesigningprojectsthatqualifyunderthebelowdesigndriven incentivestructurethatcanearnevenhigherincentivesfortheenduser.

PerformanceLightingIncentiveProgram Incentivesofupto$1.00perwattsavedbelowstateenergycodeLPDlimitsareavailable! PleaseseebelowhighlightsandreferencethePerformanceLightingapplicationformforadditional details.  Tier1$0.40perWattsavedbelowcode x Minimum15%reductioninLightingPowerDensity(W/sqft)belowEnergyCode (AbovedoesnotreferencethereducedLPDsoftheStretchEnergyCodeAppendix) x IndustrialprojectslimitedtoTier1only,including:garages,warehouse,manufacturing,etc. x Openfixtureselection,norestrictionontypesoffixturesutilized Tier2$1.00perWattsavedbelowcode x Minimum25%reductioninLightingPowerDensity(W/sqft)belowEnergyCode (AbovedoesnotreferencethereducedLPDsoftheStretchEnergyCodeAppendix) x Majorityofthelightingfixturesinstalledintheprojectmustbeofthefollowingqualifying type: ¾ HighPerformancefixtureswithoverallefficiencyratingsofatleast75% ¾ QualifyingHighPerformanceorReducedWattageT8lamps&ballasts ¾ T5orT5HOSystems ¾ LEDand/orCeramicMetalHalideDisplayLighting(excludesincandescent/halogen) **PleasenotethatLEDproductsarerequiredtobelistedoneitherEnergyStar,DLCor“Grandfathered” MassSaveLEDlisttobeeligible. 

 AdvancedBuildingsCorePerformanceIncentiveProgram AdvancedBuildingsprovideseasytoimplementguidelinesthatsupportimprovedenergyefficiencyand sustainabledesign.Thelocalutilitieshavedesignedanincentiveprogrambaseduponthesuccessful implementationofthesedesignguidelinestobenefitourcollectivecustomerbase.Pleasereference highlightsbelowandreachouttousfordesignassistancetobringtheseincentivestoyourclients.  x Incentivesavailableupto$1.50persqft. x Programavailableforbuildings20,000100,000sqft.(contactutilityforlargerprojects) x Design&EngineeringAssistanceavailablethroughoutthedesignprocess x FollowingtheseguidelineseliminatestheneedforcostlyEnergyModel

19