REPLACING ELECTRODES (H50, H100 and H200 systems) - Hidrion

Report 7 Downloads 68 Views
REPLACING ELECTRODES (H50, H100 and H200 systems) Worn out electrodes must be replaced in order for the system to carry on treating water effectively.

Replacement Electrodes are supplied pre-assembled, as shown in this picture. Each replacement contains: 1 set of 4,6 or 10 electrodes and cable connections; 1 o-ring retainer;

PRODUCED BY HIDROSWIM - SISTEMAS PARA TRATAMENTO DE ÁGUAS, LDA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 WWW.HIDRION.EU V20120924

1

STEPS:

1.

Switch off skimmer valves, drain and vacuum and return points;

2.

Switch the 6-way valve to the “closed” position;

3.

Disconnect the two connectors between the ioniser cable and the cable connecte to the Hidrion electric switchboard (electrode outlet);

4.

Loosen and remove the M5 screws (4) and nuts from the ioniser using two spanners;

PRODUCED BY HIDROSWIM - SISTEMAS PARA TRATAMENTO DE ÁGUAS, LDA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 WWW.HIDRION.EU V20120924

2

5.

Remove ioniser from the PVC container;

6.

Remove the used o-ring;

7.

Remove the top PVC lid from the cable, it will be used again;

PRODUCED BY HIDROSWIM - SISTEMAS PARA TRATAMENTO DE ÁGUAS, LDA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 WWW.HIDRION.EU V20120924

3

8.

Put the new o-ring in place;

9.

Place the new ioniser inside PVC container;

10. Place PVC lid onto the container, threading it first onto ioniser cable;

PRODUCED BY HIDROSWIM - SISTEMAS PARA TRATAMENTO DE ÁGUAS, LDA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 WWW.HIDRION.EU V20120924

4

11. Put in M5 screws (4) and respective nuts (4);

12. Be sure to tighten the screws with spanners so that o-ring does not come loose;

13. Connect ioniser cable and Hidrion switchboard connector cable (electrode t) through the connectors;

14. Open all valves which were closed at the beginning of the process;

PRODUCED BY HIDROSWIM - SISTEMAS PARA TRATAMENTO DE ÁGUAS, LDA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 WWW.HIDRION.EU V20120924

5

15. Switch the 6-way valve to “filter” position; 16. Switch on the swimming pool pump; 17. Check for any water leakage through the o-ring or loose screws. If there is any, go back to step 8;

18. Finally, use the potentiometer to adjust current intensity to its normal level.

PRODUCED BY HIDROSWIM - SISTEMAS PARA TRATAMENTO DE ÁGUAS, LDA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 WWW.HIDRION.EU V20120924

6