Capacitors
Motor Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J-3 – J-5 Motor Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .J-6 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .J-7
Definite Purpose Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J-8 Pressure Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J-12 – J-13 Switching Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J-9 – J-11 Unit Bearing Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J-14
JARD
JARD Cross Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J-15 – J-17
J–2
The largest selection of motors, components and accessories for the HVAC/R Industry
®
Motor Run Capacitors 12902
JARD NO. 12902 12903 12904 12905 12906 12907 12908 12909 12910 12912 12914 12915 12917 12918 12921 12923 12925 12924 12987 12988 12989 12990
12992
12802
12926
Single Section 370 Volt Oval MICROFARAD 2 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 55 60 65 70 80
CASE WIDTH HEIGHT INCHES INCHES 1.63 1.63 1.63 1.63 1.63 1.63 2.00 2.38 2.63 2.63 3.00 3.38 3.75 3.75 2.63 3.00 3.00 3.38 3.13 3.75 3.75 4.00
2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81
JARD NO.
MICROFARAD
12992 12993 12994 12995 12996 12997 12998 12999 12710 12911 12712 12714 12715 12717 12718 12721 12723 12725 12726 12727 12828 12729 12899 12916
2 3 4 5 6 7.5 10 12.5 15 16 17.5 20 25 30 35 40 45 50 55 60 65 70 80 100
CASE HEIGHT INCHES 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.38 2.63 2.75 3.00 3.38 3.75 3.75 4.00 3.38 3.75 4.00 3.38
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated. ®
1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81
DEPTH INCHES 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 2.00 2.00 2.00 2.50
Features:
• JARD provides a low cost alternative to popular models and the widest selection of ratings in the industry • Non-PCB capacitors. Physical interrupter makes our capacitors safe • Perfect for general replacements • Capacitor accessories – see page J-7 • UL and CSA listings available Single Section 440/370 Volt Oval
JARD NO.
MICROFARAD
12926 12919 12927 12928 12929 12930 12931 12932 12933 12934 12936 12937 12940 12941 12943 12945 12948 12949 12950 12951 12952 12830 12831 12840
2 2.5 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 55 60 65 70 75 80
CASE WIDTH HEIGHT INCHES INCHES 1.63 1.63 1.63 1.63 1.63 1.63 2.00 2.38 2.75 3.00 3.75 4.00 4.75 3.00 3.00 3.38 3.75 3.75 4.75 4.75 4.75 4.75 3.75 3.75
2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.06 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 3.56 3.56
DEPTH INCHES
Single Section 440/370 Volt Round
JARD NO.
MICROFARAD
12802 12803 12804 12805 12806 12807 12732 12733 12734 12736 12737 12740 12741 12743 12745 12748 12751 12752 12754 12657 12758 12759 12868
2 3 4 5 6 7.5 10 12.5 15 17.5 20 25 30 35 40 45 50 55 60 65 70 80 90
CASE HEIGHT INCHES 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.38 2.38 2.63 3.00 3.38 3.75 4.00 3.38 3.75 3.75 4.75 4.75 4.75 3.75 4.00
1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.21 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.88 1.88
DEPTH INCHES 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 1.75 2.00 2.00 2.00 2.00 2.00 2.00 2.50 2.50
Base Dimensions on page J-5
The largest selection of motors, components and accessories for the HVAC/R Industry
J–3
JARD
Single Section 370 Volt Round
DEPTH INCHES
129
Single Section Run Capacitors MARS SERIES
JARD
Motor Run Capacitors MARS SERIES
120
Dual Section Motor Run Capacitors
Dual section run capacitors are used primarily to serve two microfarad applications. They can, however, by making various combinations of parallel connections, be used to obtain many other microfarad ratings.
Features:
• Non-PCB capacitors. Physical interrupter makes our capacitors safe • Perfect for general replacements • Capacitor accessories – see page J-7 • UL and CSA listings available Dual Section 370 Volt Round
12841
JARD NO. 12841 12956 12957 12958 12959 12960 12961 12962 12963 12864 12964 12842 12965 12966 12843 12832 12867 12833 12844 12845 12969 12846 12847 12848 12971 12972 12849 12850 12851 12858 12871 12852 12834 12874 12853 12836 12837 12838 12854 12855 12839 12856 12857 12859 12863 12817
Dual Section 370 Volt Oval MICROFARAD 15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/3 20/4 20/5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/8 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/5 45/7.5 45/10 45/15 50/5 55/5 55/7.5 60/5 60/7.5 60/10 65/5 80/5 80/7.5
CASE WIDTH HEIGHT INCHES INCHES 2.63 2.63 2.63 2.38 2.63 2.63 2.63 3.13 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 2.63 3.00 2.63 2.63 2.63 3.00 2.63 3.00 2.63 3.00 3.00 3.00 3.75 3.75 3.75 3.75 3.75 4.75 3.75 3.75 4.75 4.75 4.75
2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 3.56 2.81
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated.
Base Dimensions on page J-5
J–4
DEPTH INCHES 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.88 1.81
JARD NO.
MICROFARAD
12701 12702 12703 12704 12705 12706 12707 12760 12716 12708 12709 12711 12875 12761 12762 12713 12720 12763 12764 12724 12728 12939 12730 12731 12766 12735 12738 12739 12767 12878 12768 12746 12747 12947 12769 12749 12750 12753 12755 12825 12757 12893 12894 12967 12976 12895 12896 12865 12742 12953 12954 12955 12744 12946 12984 12897 12819 12824 12722 12829 12756 12922
15/3 15/4 15/5 15/10 17.5/4 17.5/5 20/4 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 30/3 30/4 30/5 30/7.5 30/10 30/15 35/3 35/4 35/5 35/7.5 35/10 40/3 40/4 40/5 40/7.5 40/10 45/3 45/4 45/5 45/7.5 45/10 50/3 50/5 50/7.5 50/10 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 65/5 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 80/12.5 85/5 85/7.5 85/10
The largest selection of motors, components and accessories for the HVAC/R Industry
CASE HEIGHT INCHES 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.13 2.63 3.13 3.13 3.13 3.13 3.63 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.63 3.13 3.13 3.13 2.63 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75
DEPTH INCHES 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00
®
Motor Run Capacitors Capacitor Base Dimensions
MARS SERIES
129
Capacitor accessories – see page J-7
DEPTH
HEIGHT
DEPTH WIDTH
12780
Dual Section 440/370 Volt Oval MICROFARAD
12765 12770 12771 12777 12880 12983 12884 12882 12883 12886 12881 12887 12982 12835 12985 12879 12885 12888 12876 12772 12877 12986 12889 12773 12890 12774 12808 12913 12775 12822 12809 12776 12810 12815 12898
10/5 15/4 15/5 15/10 20/5 20/15 25/5 25/7.5 25/10 25/15 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/7.5 35/8.5 35/10 40/3 40/5 40/7.5 40/10 45/5 45/7.5 50/5 50/7.5 55/5 55/10 60/5 60/7.5 65/10 80/5 80/7.5
CASE WIDTH HEIGHT INCHES INCHES 2.63 2.63 2.63 2.63 2.63 3.00 2.63 3.00 3.00 3.75 3.75 3.00 3.75 3.75 3.00 3.75 3.75 3.00 3.00 3.75 3.75 3.75 3.75 3.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75
2.81 2.81 2.81 2.81 2.81 3.56 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 3.56 3.56 3.56
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated.
®
DEPTH INCHES 1.81 1.81 1.81 1.81 1.81 1.88 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.88 1.88 1.88
JARD NO.
MICROFARAD
12811 12818 12656 12650 12780 12654 12651 12812 12653 12655 12778 12779 12813 12814 12826 12820 12781 12782 12652 12977 12870 12783 12719 12784 12797 12978 12785 12786 12920 12787 12798 12979 12891 12788 12827 12789 12872 12790 12791 12892 12719 12792 12793 12799 12860 12794 12795 12796 12861 12642 12659 12862 12823 12866 12869 12968 12901 12935 12801 12816 12821 12938 12942 12944
10/5 15/5 15/10 17.5/5 20/5 20/7.5 20/10 20/15 25/3 25/4 25/5 25/7.5 25/10 25/15 30/3 30/4 30/5 30/7.5 30/10 35/3 35/4 35/5 35/6 35/7.5 35/10 40/3 40/4 40/5 40/6 40/7.5 40/10 45/3 45/4 45/5 45/6 45/7.5 45/10 50/5 50/7.5 50/10 50/12.5 55/5 55/7.5 55/10 60/3 60/5 60/7.5 60/10 60/12.5 65/5 65/7.5 65/10 70/5 70/7.5 70/10 75/5 75/7.5 75/10 80/5 80/7.5 80/10 85/5 85/7.5 85/10
CASE HEIGHT INCHES
The largest selection of motors, components and accessories for the HVAC/R Industry
3.13 3.13 3.63 3.63 3.63 3.63 3.13 3.13 3.13 3.13 3.63 3.13 3.13 3.13 3.13 3.13 3.13 3.13 3.88 3.88 3.88 3.13 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 4.75 4.75 3.88 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 3.88 4.75 4.75 4.75
DEPTH INCHES 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 0.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.50
J–5
JARD
JARD NO.
Dual Section 440/370 Volt Round
Motor Start Capacitors MARS SERIES
119
JARD Motor Start Capacitors provide a low cost alternative to popular models available. MARS offers the largest assortment of capacitor ratings in the industry.
These electrolytic capacitors feature a hermetically sealed black bakelite case which permanently protects the capacitor from oil, dirt, grease or moisture. Capacitor accessories – see page J-7 JARD NO.
11908
JARD NO.
JARD
11902 11903 11904 11905 11906 11907 11908 11909 11910 11912 11911 11913 11914 11915 11916 11917 11918 11919 11920 11921 11922 11923 11924 11971 11925 11926 11927 11947 11928 11972 11929 11973 11930 11974
JARD NO.
J–6
11975 11976 11977 11931 11932 11933 11934 11978 11935 11936 11979 11980 11994 11981 11982 11983
110/125 Dual Voltage AC MICROFARAD 21-25 25-30 30-36 36-43 43-56 56-67 72-88 88-108 108-130 124-156 130-156 145-175 161-193 189-227 200-240 216-259 233-292 270-324 300-360 324-388 340-408 378-440 400-480 430-516 460-552 540-648 590-708 645-774 708-850 815-970 829-995 850-1020 1000-1200 1290-1548
165 Volts AC MICROFARAD 72-88 88-108 108-130 124-149 145-175 161-193 189-227 216-259 233-292 270-324 340-408 378-455 400-480 540-648 710-850 810-972
CASE SIZE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 4 4 4 4 4 4 4 5 5 5 5 5
CASE SIZE 1 1 1 1 1 1 1 2 2 2 4 4 4 4 5 5
11938 11939 11940 11941 11942 11943 11984 11937 11944 11945 11946 11948 11949 11950 11951 11952 11953 11954 11985 11986 11987 11988 11989 11990 11991
JARD NO. 11955 11956 11957 11958 11959 11995 11960 11961 11962 11963 11964 11965 11992 11966 11967 11968 11969 11970 11993
CASE SIZE 1 2 4 5 6 7 8
220/250 Dual Voltage AC MICROFARAD CASE SIZE 21-25 25-30 30-36 36-43 43-56 56-72 59-71 64-77 72-88 88-108 108-130 124-156 145-175 161-193 189-227 216-259 233-292 270-324 280-336 320-384 340-408 378-455 400-480 430-516 630-750
330 Volts AC MICROFARAD 21-25 25-30 30-36 36-43 43-56 56-72 64-77 72-88 88-108 108-130 130-156 124-156 135-162 145-175 161-193 189-227 216-259 270-324 300-360
CASE DIMENSIONS* DIAMETER IN INCHES 1.44 1.44 1.81 1.81 2.06 2.06 2.56
1 1 1 1 1 1 1 1 1 2 4 4 4 5 5 5 5 5 4 4 4 5 5 5 8
CASE SIZE 1 1 1 1 4 2 4 4 4 4 5 5 5 5 5 5 7 7 8
LENGTH INCHES 2.75 3.38 3.38 4.38 3.38 4.38 4.38
*Capacitors may be put in different case sizes occasionally, but will not be larger than those stated.
The largest selection of motors, components and accessories for the HVAC/R Industry
®
Capacitor Accessories Accessories for Relays and Capacitors QC-6 Kit
93001
For conversion of screw-type connections on relays
Resistor for Start Capacitors 93007
93106
- 10 pc 2 watt (15,000 ohm) resistors with .25in female spade connectors
Snap-on Mounting Brackets for Motor Start Capacitors
Oval
93014
1.94 x 2.78 for base A
93015
1.97 x 2.94 for base C
93116
2.25 x 3.66 for base D
Oval
2.75 in 3.38 in 4.38 in
93011
1 Hole Boot
93012
2 Hole Boot
93013
3 Hole Boot for Dual Section
Protector (boots) for Motor Run Capacitors
®
Oval
Mounting Brackets for Round Capacitors 93031 - For 1.63 in and 1.75 in diam
93032 - For 2.0 in diam 93033 - For 2.50 in diam
Bakelite End Caps for Motor Start Capacitors
93018 93019 93020 93021
93022 93023 93024 93025
-
-
BEC-1 BEC-2 BEC-3 BEC-4
1.44 in 1.81 in 2.06 in 2.56 in
JARD
93026 93027 93028
930
Wrap-Around Brackets for Motor Run Capacitors
- 2 watt (15,000 ohm) Resistors
QC-13 for Start Capacitors
MARS SERIES
For mounting OFF MOTOR. Leads on top side. BEC-1 BEC-2 BEC-3 BEC-4
1.44 in 1.81 in 2.06 in 2.56 in
The largest selection of motors, components and accessories for the HVAC/R Industry
J–7
Definite Purpose Contactors MARS SERIES
173
Definite Purpose Contactors
“A Low Cost Alternative By The Name You Trust”
JARD Definite Purpose Contactors are designed for use on refrigeration, air conditioning, and electric heating systems. The universal mounting base allows replacement of most contactor brands. Power connections can be made with either screws & quick connects or lugs & quick connects depending on the style.
Features:
17125
JARD
JARD W/LUGS
J–8
17125 17126 17127 17215 17216 17217 17225 17226 17227 17315 17316 17317 17325 17326 17327 17335 17336 17337 17415 17416 17417 17425 17426 17427 17435 17436 17437 17535 17536 17537 17635 17636 17637 17735 17736 17737 17935 17936 17937 17997 17998 17999
• 2 styles: screw terminals with quick connects or lug terminals with quick connects • UL (both styles) • CSA (screw terminal style) • CUL (lug terminal style)
17999 JARD W/SCREWS
FULL LOAD AMPS
17121 20 17122 20 17123 20 – 25 – 25 – 25 17221 25 17222 25 17223 25 17311 30 17312 30 17313 30 17321 30 17322 30 17323 30 17331 30 17332 30 17333 30 – 40 – 40 – 40 – 40 – 40 – 40 – 40 – 40 – 40 – 50 – 50 – 50 – 60 – 60 – 60 – 75 – 75 – 75 – 90 – 90 – 90 Auxiliary Contact- Fits 75 & 90A 3P models Auxiliary Contact- Fits 50 & 60A 3P models Auxiliary Contact- Fits 40A 3P models
RESISTIVE AMPS 30 30 30 35 35 35 35 35 35 40 40 40 40 40 40 40 40 40 50 50 50 50 50 50 50 50 50 65 65 65 75 75 75 90 90 90 120 120 120
COIL VOLTAGE 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240 24 120 240
The largest selection of motors, components and accessories for the HVAC/R Industry
POLES 2 2 2 1-1/2 1-1/2 1-1/2 2 2 2 1-1/2 1-1/2 1-1/2 2 2 2 3 3 3 1-1/2 1-1/2 1-1/2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
®
Switching Relays General Purpose Switching Relays
MARS SERIES
902
JARD SPST and SPDT Fan Relays are among the most popular electromechanical relays used in air conditioning, heating and refrigeration today.
Features:
92290
• • • • •
16 Amp switching 55 Amp inrush current Quick-connect terminals Universal mounting bracket UL and CUR
switch diagrams: 2
4
1
3
92290 92291 92292
92293
92293 92294 92295
JARD
JARD NO.
SPST 92290 92291 92292
24 110-120 208/240
8 amps continuous 25 amps inrush
16 amps 16 amps 16 amps
90-290, 90-290Q 90-291, 90-291Q 90-292, 90-292Q
92293 92294 92295
24 110-120 208/240
8 amps continuous 25 amps inrush
16 amps 16 amps 16 amps
90-293, 90-293Q 90-294, 90-294Q 90-295, 90-295Q
SPDT
®
NORMALLY OPEN CONTACT RATING COIL 125/250 VAC REPLACES VOLTAGE INDUCTIVE RESISTIVE ESSEX/RBM NO.
The largest selection of motors, components and accessories for the HVAC/R Industry
J–9
Switching Relays MARS SERIES
902
Heavy Duty Fan Switching Relays
JARD Heavy Duty Fan Relays are used on heating and air conditioning equipment to provide switching of heavier loads with a compact size relay.
Features:
• 25 Amp switching • Universal mounting bracket • Quick-connect terminals • UL and CUR 92362
Model Identification COIL VOLTAGE
JARD NO. SPST-NO.
JARD NO. NO. SPDT
JARD NO. SPNO-SPNC
110/120
92362
92372
92382
24
208/240
92360 92364
92370 92374
Contact Rating VOLTAGE
92380
120
92384
277
240
FULL LOAD
LOCKED ROTOR
RESISTIVE
8
48
18
12 7
60
18
42
18
JARD
Terminal Identification
Cross Reference:
ESSEX/RBM 90-360Q 90-362Q 90-364Q 90-370Q 90-372Q
J–10
JARD NO. 92360 92362 92364 92370 92372
ESSEX/RBM 90-374Q 90-380Q 90-382Q 90-384Q
JARD NO. 92374 92380 92382 92384
The largest selection of motors, components and accessories for the HVAC/R Industry
®
Switching Relays 2PDT HVAC Relays
MARS SERIES
902
JARD 2PDT relays are primarily used for various applications in heating, air conditioning and refrigeration. They are also suitable for general purpose switching applications in appliances, vending machines, fan controls, and business machines provided the device being controlled is within the electrical limits of the relay.
Features: • • • • • •
92340
Replaces Honeywell, White-Rodgers/RBM 2.13 x 1.88 x 2.25 inches Quick-connect terminals Base designed for easy replacement of competitive relays Molded terminal numbers and circuit diagram on top of relay UL and CUR
Contact Rating 1 2
4
6 5
COIL VOLTAGE
92340 92341 92342
24 110/120 208/240
®
PILOT
Full load Amps Resistive Locked Rotor Amps Horsepower
TERMINALS 1-2-3
TERMINALS 4-5-6
Power
Power
120V
12 15 60 3/4
277V
6 15 35 3/4
208/240V
120V
3 1/10
CROSS REFERENCE ESSEX / RBM 90-340 90-341 90-342
The largest selection of motors, components and accessories for the HVAC/R Industry
277V
3 1/10
HONEYWELL R8222D1014 R4222D1013 R4222N1021
J–11
JARD
COIL Terminals 1& 2, 4 & 5 are normally closed Terminals 1& 3, 4 & 6 are normally open
JARD NO.
POWER
208/240V
3
JARD
JARD Pressure Switches MARS SERIES
339
Fixed Setting Pressure Controls High Pressure Cut-Outs
JARD offers the most complete line of high pressure cut-outs available.
Features:
• Tamper proof construction • Direct mounting on tubing
Specifications: • • • •
Contacts rated at 6 amps, 24-240 volts ¼” female flare S.A.E. mounting 18” leads UL & CSA recognized
High Pressure Cut-Outs, Open on Pressure Rise, Automatic Reset, Normally Closed JARD NO.
FORMER MARS2 NO.
43924
33910
43922 43925 43926 43920 43927 43928 43929 43930 43931 43911
J–12
275
195
300/200 HP Open on rise
33913 33916 33956 33919 33957 33922 33958
33959
43939
275/195 HP Open on rise
33955
43934 43935
RESET PRESSURE
200/150 HP Open on rise
33925
43965
OPENING PRESSURE
33954
43932 43933
DESCRIPTION
325/225 HP Open on rise 350/245 HP Open on rise 350/250 HP Open on rise 375/275 HP Open on rise 400/200 HP Open on rise 400/280 HP Open on rise 400/300 HP Open on rise 410/290 HP Open on rise 425/300 HP Open on rise
425/325 HP Open on rise 450/250 HP Open on rise 590/418 HP Open on rise 600/475 HP Open on rise 630/480 HP Open on rise
250 300 325 350 350 375 400 400 400 410 425 425 450 590 600 630
MOUNTING
150
1/4" Female Flare Fitting S.A.E. Mounting
200
1/4" Female Flare Fitting S.A.E. Mounting
225 245 250 275 200 280 300 290 300 325 250 418 475 480
1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting
The largest selection of motors, components and accessories for the HVAC/R Industry
®
JARD Pressure Switches Low Pressure Controls
MARS SERIES
339
Features:
• Tamper proof construction • Direct mounting on tubing
Specifications: • • • •
Contacts rated at 6 amps, 24-240 volts ¼” female flare S.A.E. mounting 18” leads UL & CSA recognized
Low Pressure Controls, Open on Pressure Fall, Automatic Reset, Normally Open FORMER MARS2 NO.
JARD NO. 43941 43942 43943 43944 43945 43946 43947 43948 43949 43950 43951 43952 43953 43975 43954 43955
33929 33930 33933 33962 33936 33963 33964 33939
DESCRIPTION
5/20 LP Open on fall 5/30 LP Open on fall 10/25 LP Open on fall 15/35 LP Open on fall 20/45 LP Open on fall 25/50 LP Open on fall 25/65 LP Open on fall 25/80 LP Open on fall 35/60 LP Open on fall 40/80 LP Open on fall 45/60 LP Open on fall 50/90 LP Open on fall 75/100 LP Open on fall 90/120 LP Open on fall 150/225 LP Open on fall 170/225 LP Open on fall
OPENING PRESSURE 5 5 10 15 20 25 25 25 35 40 45 50 75 90 150 170
RESET PRESSURE 20 30 25 35 45 50 65 80 60 80 60 90 100 120 225 225
1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting
JARD
Condenser Fan Cycling Switch
MOUNTING
Manual Reset high pressure controls
43903
Specifications:
• UL & CSA recognized JARD FORMER NO. MARS2 NO.
43901 43902 43903 43904
33940
43970 43905 43906 43907 43912 43913 43916
33941 33965
®
DESCRIPTION
OPENING PRESSURE
RESET PRESSURE
110/170 FC Close on rise
110
170
75/100 FC Close on rise
75
125/265 FC Close on rise
125
180/240 FC Close on rise
180
150/225 FC Close on rise 19/275 FC Close on rise
210/275 FC Close on rise 300/400 FC Close on rise 375/Man. Open on rise 410/Man. Open on rise 475/Man. Open on rise
150 190 210 300
SWITCH ACTION (OPEN ON PRESSURE)
1/4" Female Flare Fitting S.A.E. Mounting
Fall
100
1/4" Female Flare Fitting S.A.E. Mounting
265
1/4" Female Flare Fitting S.A.E. Mounting
225 240 275 275 400
375
Manual
475
Manual
410
MOUNTING
Manual
1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting 1/4" Female Flare Fitting S.A.E. Mounting
Fall Fall Fall Fall Fall Fall Fall
1/4" Female Flare Fitting S.A.E. Mounting
Rise
1/4" Female Flare Fitting S.A.E. Mounting
Rise
1/4" Female Flare Fitting S.A.E. Mounting
The largest selection of motors, components and accessories for the HVAC/R Industry
Rise
J–13
JARD
Unit Bearing Motors MARS SERIES
150
Unit Bearing Motors
JARD Unit Bearing Cast Iron Motors are used on refrigerators, freezers, food & beverage coolers, vending machines, display cases, and many other fan duty applications.
Features:
15109
JARD NO.
15109 15211 15212 15221 15222 15311 15312 15119* 15411 15412 15421 15422 15811 15812 15821 15822
WATTS 2 4 4 4 4 6 6 9 9 9 9 9 16 16 16 16
* Note: 13” lead with lyall plug
J–14
VOLTAGE 115 115 115 230 230 115 115 115 115 115 230 230 115 115 230 230
• • • • •
Cast iron construction Universal mount Mounting screws included Individually boxed UL recognized
ROTATION CW CW CCW CW CCW CW CCW CW CW CCW CW CCW CW CCW CW CCW
AMPS 0.28 0.33 0.33 0.19 0.19 0.46 0.46 0.62 0.62 0.62 0.33 0.33 0.95 0.95 0.48 0.48
LEAD LENGTH 24" 24" 24" 24" 24" 24" 24" 13" 24" 24" 24" 24" 24" 24" 24" 24"
The largest selection of motors, components and accessories for the HVAC/R Industry
®
JARD to MARS Cross Reference Guide Start Capacitors MARS 11003 11004 11005 11006 11007 11008 11009 11010 11013 11014 11015 11016 11017 11018 11019 11020 11021 11022 11023 11024 11025 11026 11027 11028 11029 11030 11031 11032 11033 11034 11035 11036 11037 11038 11039 11040 11041 11042 11043 11044 11045 11046 11049 11050 11051 11052 11053 11054 11055 11056 11057 ®
Start Capacitors JARD 11958 11959 11995 11961 11962
MARS 11058 11059 11060 11061 11062
JARD 12902 12903 12904 12905 12906 12907 12908 12909 12910 12912 12914 12915 12917 12918 12921 12923 12925 12924 12987 12988 12989 12990 12841 12956 12957 12958 12959 12960 12961 12962 12963 12864 12964 12842 12965 12966 12843 12832 12867 12833 12844 12845 12969 12846 12847
MARS 12002 12003 12004 12005 12006 12007 12008 12009 12010 12012 12014 12015 12017 12018 12021 12023 12025 12024 12087 12011 12089 12090 12141 12056 12057 12058 12059 12060 12061 12062 12063 12064 12164 12142 12065 12066 12143 12131 12167 12133 12144 12145 12069 12146 12147
Run Capacitors
Run Capacitors JARD 12848 12971 12972 12849 12850 12851 12858 12871 12852 12834 12874 12853 12836 12837 12838 12854 12855 12839 12856 12857 12859 12863 12817 12926 12919 12927 12928 12929 12930 12931 12932 12933 12934 12936 12937 12940 12941 12943 12945 12948 12949 12950 12951 12952 12830 12831 12840 12765 12970 12770 12771 12777 12880
MARS 12148 12071 12072 12149 12150 12151 12158 12171 12152 12134 12174 12153 12136 12137 12138 12154 12155 12139 12156 12157 12159 12163 12123 12026 12019 12027 12028 12029 12030 12031 12032 12033 12034 12036 12037 12040 12041 12043 12045 12048 12049 12050 12051 12052 12130 12135 12140 12165 12170 12270 12271 12177 12180
Run Capacitors JARD 12983 12884 12882 12883 12886 12881 12887 12982 12835 12985 12879 12885 12888 12876 12772 12877 12986 12889 12773 12890 12774 12808 12913 12775 12822 12809 12776 12810 12815 12898 12992 12993 12994 12995 12996 12997 12998 12999 12710 12911 12712 12714 12715 12717 12718 12721 12723 12725 12726 12727 12828 12729 12899
MARS 12083 12184 12182 12183 12186 12181 12187 12038 12035 12085 12179 12185 12188 12176 12272 12080 12086 12189 12273 12190 12274 12108 12013 12275 12276 12109 12110 12101 12297 12298 12092 12093 12094 12095 12096 12097 12098 12099 12210 12211 12212 12214 12215 12217 12218 12221 12223 12225 12226 12227 12128 12229 12199
The largest selection of motors, components and accessories for the HVAC/R Industry
Run Capacitors JARD 12916 12701 12702 12703 12704 12705 12706 12707 12760 12716 12708 12709 12711 12875 12761 12762 12713 12720 12763 12764 12724 12728 12939 12730 12731 12766 12735 12738 12739 12767 12878 12768 12746 12747 12947 12769 12749 12750 12753 12755 12825 12757 12893 12894 12967 12976 12895 12896 12865 12742 12953 12954
MARS 12116 12121 12122 12203 12204 12205 12206 12207 12260 12016 12208 12209 12242 12175 12261 12262 12213 12244 12263 12264 12224 12228 12039 12082 12231 12266 12235 12238 12074 12267 12178 12268 12246 12073 12247 12269 12249 12250 12075 12191 12192 12239 12193 12194 12067 12076 12195 12196 12265 12042 12053 12054
J–15
JARD
JARD 11903 11904 11905 11906 11907 11908 11909 11910 11913 11914 11915 11916 11917 11918 11919 11920 11921 11922 11923 11924 11925 11926 11927 11928 11929 11930 11931 11932 11933 11934 11935 11936 11994 11938 11939 11940 11941 11942 11943 11944 11945 11946 11949 11950 11951 11952 11953 11954 11955 11956 11957
Cross Reference Guide
JARD
Cross Reference Guide
JARD to MARS Cross Reference Guide Run Capacitors
JARD 12955 12744 12946 12984 12897 12819 12824 12722 12829 12756 12922 12802 12803 12804 12805 12806 12807 12732 12733 12734 12736 12737 12740 12741 12743 12745 12748 12751 12752 12754 12758 12759 12868 12811 12818 12656 12650 12780 12654 12651 12812 12653 12655 12778 12779 12813 12814 12826 12820 12781 12782 12652
J–16
MARS 12055 12044 12046 12084 12197 12198 12201 12202 12129 12230 12222 12102 12103 12104 12105 12106 12107 12232 12233 12234 12236 12237 12240 12241 12243 12245 12248 12251 12252 12254 12258 12259 12068 12111 12118 12356 12350 12115 12354 12351 12112 12353 12355 12278 12279 12113 12114 12126 12120 12281 12282 12352
Run Capacitors JARD
12977 12870 12783 12719 12784 12797 12978 12785 12786 12920 12787 12798 12979 12891 12788 12827 12789 12872 12790 12791 12892 12719 12792 12793 12799 12860 12794 12795 12796 12861 12862 12823 12866 12869 12968 12901 12935 12801 12816 12821 12938 12942 12944
MARS 12077 12070 12283 12119 12284 12091 12078 12285 12286 12220 12287 12088 12079 12219 12288 12127 12289 12172 12290 12291 12124 12253 12292 12293 12299 12160 12294 12295 12296 12161 12162 12255 12166 12169 12168 12125 12047 12257 12216 12117 12022 12020 12001
Contactors JARD 17121 17122 17123 17125 17126 17127
MARS
Contactors JARD 17215 17216 17217 17221 17222 17223 17225 17226 17227 17311 17312 17313 17315 17316 17317 17321 17322 17323 17325 17326 17327 17331 17332 17333 17335 17336 17337 17415 17416 17417 17425 17426 17427 17435 17436 17437 17535 17536 17537 17635 17636 17637 17735 17736 17737 17935 17936 17937 17997 17998 17999
MARS
91311 91312 91313 91315 91316 91317 91321 91322 91323 91325 91326 91327 91331 91332 91333 91335 91336 91337 91411 91421 91422 91423 91431 91432 91433 91531 91532 91533 91631 91632 91633 91731 91732 91733
91999 91998 91997
Pressure Switches JARD 43901 43902 43903 43904 43905 43906 43907 43911 43912 43913 43916 43920 43922 43924 43925 43926 43927 43928 43929 43930 43931 43932 43933 43934 43935 43939 43941 43942 43943 43944 43945 43946 43947 43948 43949 43950 43951 43952 43953 43954 43955 43965 43970 43975
MARS 43301 43302 43303 43304 43305 43306 43307 43311 43312 43313 43316 43320 43322 43324 43325 43326 43327 43328 43329 43330 43331 43332 43333 43334 43335 43339 43341 43342 43343 43344 43345 43346 43347 43348 43349 43350 43351 43352 43353 43354 43355 43365 43370 43375
JARD 32001 32091
MARS 32392 32391
Solid State Controls
The largest selection of motors, components and accessories for the HVAC/R Industry
®
JARD to MARS Cross Reference Guide
Cross Reference Guide
Switching Relays JARD 92290 92291 92292 92293 92294 92295 92340 92341 92342 92360 92362 92364 92370 92372 92374 92380 92382 92384
MARS 90290 90291 90292 90293 90294 90295 90340 90341 90342 90360 90362 90364 90370 90372 90374 90380 90382 90384
JARD 15109 15119 15211 15212 15221 15222 15311 15312 15411 15412 15421 15422 15811 15812 15821 15822
MARS 05109 05119 05211 05212 05221 05222 05311 05312 05411 05412 05421 05422 05811 05812 05821 05822
Unit Bearing Motors
JARD
®
The largest selection of motors, components and accessories for the HVAC/R Industry
J–17