Savant Wireless Thermostat (SST-W100) Quick Reference Guide

Report 8 Downloads 116 Views
009-0793-02 SST-W100-00

Savant Wireless Thermostat (SST-W100) Quick Reference Guide

The Savant Wireless Thermostat (SST-W100) is a Wi-Fi enabled wireless digital thermostat designed to control Heating, Ventilation and Air Conditioning (HVAC) systems which communicate wirelessly over Wi-Fi to a Savant System. The SST-W100 is designed to integrate seamlessly into a Savant controlled environment.

Holes for mounting on wall screws

Box Contents (1) SST-W100 (1) Installation Kit (xxx) (1) Quick Reference Guide (this document)

Optional Components One of the 16 screw-down connectors used for wiring to climate control devices

SST-TEMP1 - Remote Temperature Sensor

Specifications Environmental Temperature

32° to 104° F (0° to 40° C)

Humidity

10% to 90% Relative Humidity (non-condensing)

Rear View of SST-W100

Height

3.96 in/10.06 cm

Wiring

Width

5.775 in/14.67 cm

Depth

.58 in/1.47 cm

Weight

0.5 lb/.23 kg

Dimensions and Weight Screw-down connectors on the inside of the back cover of the SST-W100 are used for wiring connections to various climate control devices. Use the next figure to identify these connectors described in the next table.

Power Power Supply

24V AC (requires both R and C from the HVAC system)

Maximum Power Draw

200mA

Compliance Safety and Emissions

FCC Part 15 | UL Class 2

RoHS

Compliant

Screw-down Connectors on SST-W100 Left Side 24RC

Cooling 24V

24C

G

Fan Output

24RH

Y1

Cooling Stage 1 output (Compressor)

Front View of SST-W100 Backlite Display

Time

Outside Temperature

Relative Humidity

Right Side

W1

24V AC Common (Required) 24V Heating Heat Stage 1 output (standard gas/electric HVAC) Auxiliary Heating (heat pump HVAC)

Setpoints

Y2

Cooling Stage 2 output (Compressor)

W2/O

Heat Stage 2 output (standard gas/electric HVAC) Change Over Valve (heat pump HVAC)

Warmer System Status Colder

Room Temperature

RS2

Remote Sensor 2

RS1

Remote Sensor 1

RS2

Remote Sensor 2

RS1

Remote Sensor 1

RSC

Sensor Shield

RSC

Sensor shield

A1

Menu Heating/Cooling Mode Selection

Fan Mode Selection

Run/Hold Mode Selection

Auxiliary 1 Relay

A2

Auxiliary 2 Relay

NOTE: The Savant Wireless Remote Temperature Sensor (SST-TEMP1) Quick Reference Guide is available at: dealers.SavantSystems.com Savant Hardware > Energy Management

Front View with Callouts

053013

009-0793-02 SST-W100-00

Savant Wireless Thermostat (SST-W100) Quick Reference Guide Standard Gas/Electric HVAC System Wiring

Standard Gas/Electric HVAC System Wiring

Heat Pump HVAC System Wiring

Heat Pump HVAC System Wiring Standard Gas/Electric HVAC System Wiring

Thermostat back

Thermostat back

Optional 24R Connection for single transformer HVAC Systems RC and RH are jumpered together on thermostat board. Cut RC/RH jumper JP1 for separate heating & cooling transformers

Cooling 24V Fan Cooling stage 1 Cooling stage 2 Remote Sensor 2 Remote Sensor 2 Sensor shield

A1 Relay Humidity Relay Com

24RC G Y1 Y2 RS2 RS2 RSC HC A1

24C 24RH W1 W2/O RS1 RS1 RSC H1 A2

Thermostat back For Heat Pump systems, connect the 24R connection to either the 24RC or 24RH Optional 24R Connection for single transformer HVAC Systems RC and RH are jumpered together on thermostat board. Cut RC/RH jumper JP1 for separate heating & cooling transformers

*

24VAC Com

Cooling 24V

24V Heating

CoolingFan 24V Cooling stage Fan1

Heating stage 1 Heating stage 2 Remote Sensor 1

Cooling Coolingstage stage21

Remote Sensor 1

Remote Sensor Cooling stage22

Sensor shield

Remote RemoteSensor Sensor22 Sensor shield2 Remote Sensor

A2Humidity Relay Relay

shield A1 Relay HumiditySensor Relay Com

A1 Relay Humidity Relay Com

Shielded cable

24RC G 24RC Y1 G Y2 Y1 RS2 Y2 RS2 RSC RS2 RSC A1 HC HC

24VAC Com 24V Heating 24VAC Com Heating 24VAux Heating Change Over Heating stage 1 Valve Remote Sensor 1 Heating stage 2 Remote Sensor Remote Sensor 1 1 Sensor shield1 Remote Sensor Sensor shield A2 Relay Humidity Relay

A2Humidity Relay Relay

Shielded cable

Shielded cable Shielded cable Remote Sensor RS2

Shielded cable Shielded cable

Remote Sensor RS1

Remote Sensor RS1 Remote Sensor RS1

Remote RemoteSensor SensorRS2 RS2

Contact Common Closure 24VAC Input

Standard HVAC System Contact Common Contact Closure 24VAC Closure Contact Closure Input Input

Thermostat Connection Optional Feature Humidifier/Dehumidifier

Input

C 24VAC Common

Optional Feature Optional Feature Humidifier/Dehumidifier Humidifier/Dehumidifier

R 24VAC Return W1 Heat Stage1

Common 24VAC

W2 Heat Stage 2 G Fan

Common 24VAC Contact Closure Input

Y1 Compressor Stage 1 Y2 Compressor Stage 2

Thermostat Setup:

Optional Feature Dehumidifier Thermostat Setup: Standard Gas/Electric HVAC Systems To set the HVAC system type, go to the Main Menu Thermostat Info screen and press hold the Setup button. there is and a separate transformer for the heating and cooling

Heat Pump HVAC Systems To set the HVAC system type, go to the Main Menu Optional Feature Thermostat Info screen and press and hold the Setup button.

2. Fan Type. Set the HVAC Fan Type:

x

2

nd

Heat Pump HVAC System Standard HVAC System ThermostatConnection Connection Thermostat 24VAC Common C C24VAC Common R 24VAC Return R 24VAC Return W1 Aux Heat W1 Heat Stage1 O/B Change Over Valve W2 Heat Stage 2 Fan G GFan Compressor Stage Y1Y1 Compressor Stage 1 1 Y2Y2Compressor Stage 2 2 Compressor Stage

Dehumidifier Thermostat Setup:

Default Setup:

NOTE:If system, clip the jumper x HVAC Type: Gas/Elec x board. Fan Type: Gas (JP1)located next to the mini-USB connector on the right side of the circuit 1. Type. Set the HVAC System Type: set to Gas/Elec nd Stage Heat: No

x Deployment 2 Stage Cool:Guide No For installation of the SST-W100 SST-W100 Set to Gas for typicalWireless gas furnaceThermostat, (fan is controlledsee by thethe furnace) available at: dealers.SavantSystems.com Set to Elec for electric heat (fan call with heat call) No setup required for this 3. 2nd Stage Heat. Enable second stage heating outputs Savant Hardware > Energy Management configuration If you have a single stage heating system, leave this set to N If you have a 2 stage heating system, set to Y to enable. 4. 2nd Stage Cool. Enable second stage cooling outputs If you have a single stage cooling system, leave this set to N. If you have a two stage cooling system, set to Y to enable.

DCN: 141-02048-01

24C 24RH 24C W1 24RH W2/O W1 RS1 W2/O RS1 RS1 RSC RS1 RSC A2 H1 H1

Page 19

Standard HVAC Systems 1. Type. Set theGas/Electric HVAC System Type: set to Heat Pump To set the HVAC system type, go to the Main Menu Thermostat Info screen Defaultby Setup: 2. C/O type. Change Over (reversing) Valve Type. Heat pumps change from heating to cooling reversing operation. and press and hold the Setup button. x HVAC Type: Gas/Elec Energy Management If you Ifhave single system, set leave set to N you a have a 2 stage stage heating heating system, to Ythis to enable. Note! If you get heating when you you have 2 stagesecond heatingstage system, set to Y to enable. 4. 2nd IfStage Cool.a Enable cooling outputs expected cooling, change the C/O 4. Aux Heat (HP). IfIfyou youhave have heat strips,system, set thisleave to Y to enable. a auxiliary single stage cooling this set to N. type to the opposite setting. 5. 2nd Stage Cool.If you Enable stagecooling coolingsystem, outputsset to Y to enable. havesecond a two stage If you have a single stage cooling system, leave this set to N. If you have a two stage cooling system, set to Y to enable.

Additional Documentation

DCN: 141-02048-01

DCN: 141-02048-01

Page 19

Page 20

Copyright © 2012 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC. All brand names, product names and trademarks are the property of their respective owners. Savant Systems, LLC reserves the right to change product specifications without notice.

053013