Terminal Blocks Fuseholders 30 A Rated Class 9080
Maximum Voltage Rating Wire Range (based on 75° C wire) Wire Type Lug Termination Clip Material
Class H Fuses
Class R Fuses
250
600
250
600
#18 to #10 AWG
#18 to #10 AWG
#18 to #10 AWG
#18 to #10 AWG
Solid or Stranded
Solid or Stranded
Solid or Stranded
Solid or Stranded
Copper Wire
Copper Wire
Copper Wire
Copper Wire
Pressure Wire
Pressure Wire
Pressure Wire
Pressure Wire
Connector
Connector
Connector
Connector
Copper Alloy
Copper Alloy
Copper Alloy
Copper Alloy
Tin Plated
Tin Plated
Tin Plated
Tin Plated
Clip Type
Reinforced
Reinforced
Reinforced
Reinforced
Base Material
High Impact Thermoplastic
General Purpose Phenolic
High Impact Thermoplastic
General Purpose Phenolic
Recommended Tightening Torque
25 lbf-in (2.8 N-m)
25 lbf-in (2.8 N-m)
25 lbf-in (2.8 N-m)
25 lbf-in (2.8 N-m)
Temperature Rating Fuse Size (Via. x Length) AIC Rating in accordance with UL512 Certifications Flammability Rating
-40 to 257° F
-40 to 302° F
-40 to 257° F
-40 to 302° F
-40 to 125° C
-40 to 150° C
-40 to 125° C
-40 to 150° C
9/16" x 2"
13/16" x 5"
9/16" x 2"
13/16" x 5"
10,000
10,000
200,000
200,000
File E40747 Guide IZLT2 UL94V-0
¨
File 70360/ Class 6225-01 UL94V-0
RoHS Compliant
Marked
UL94V-0
UL94V-0
One Pole Blocks Catalog Number Dimensions (D) x (H) x (W)
9080FB1211
9080FB1611
9080FB1211R
9080FB1611R
1.38 x 3.00 x 1.12 in.
1.69 x 6.25 x 1.63 in.
1.38 x 3.00 x 1.12 in.
1.69 x 6.25 x 1.63 in.
35.1 x 76.2 x 28.4 mm
42.9 x 159.0 x 41.4 mm
35.1 x 76.2 x 28.4 mm
42.9 x 159.0 x 41.4 mm
Two Pole Blocks Catalog Number Dimensions (D) x (H) x (W)
9080FB2211
9080FB2611
9080FB2211R
9080FB2611R
1.38 x 3.00 x 1.91 in.
1.69 x 6.25 x 2.94 in.
1.38 x 3.00 x 1.91 in.
1.69 x 6.25 x 2.94 in.
35.1 x 76.2 x 48.5 mm
42.9 x 159.0 x 74.7 mm
35.1 x 76.2 x 48.5 mm
42.9 x 159.0 x 74.7 mm
Three Pole Blocks Catalog Number Dimensions (D) x (H) x (W)
9080FB3211
9080FB3611
9080FB3211R
9080FB3611R
1.38 x 3.00 x 2.95 in.
1.69 x 6.25 x 4.25 in.
1.38 x 3.00 x 2.95 in.
1.69 x 6.25 x 4.25 in.
35.1 x 76.2 x 74.9 mm
42.9 x 159.0 x 108 mm
35.1 x 76.2 x 74.9 mm
42.9 x 159.0 x 108 mm
9080FBDIN3
N/A
9080FBDIN3
N/A
DIN 3 (35 mm) Track Adapter
12 04/2009
© 1993 - 2009 Schneider Electric All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Terminal Blocks Fuseholders 30 A Rated Class 9080
Class M Fuses
Class CC Fuses
Class J Fuses
600
600
600
#18 to #10 AWG
#18 to #10 AWG
#14 to #6 AWG
Solid or Stranded
Solid or Stranded
Solid or Stranded
Copper Wire
Copper Wire
Copper Wire
Pressure Wire
Pressure Wire
Box Lug
Connector
Connector
Connector
Copper Alloy
Copper Alloy
Copper Alloy
Tin Plated
Tin Plated
Tin Plated
Clip Type
Standard
Standard
Reinforced
Base Material
High Impact Thermoplastic
High Impact Thermoplastic
High Impact Thermoplastic
Recommended Tightening Torque
25 lbf-in (2.8 N-m)
25 lbf-in (2.8 N-m)
25 lbf-in (2.8 N-m)
-40 to 257° F
-40 to 257° F
-40 to 257° F
-40 to 125° C
-40 to 125° C
-40 to 125° C
13/32" x 1 1/2"
13/32" x 1 1/2"
13/16"x2 1/4"
100,000
200,000
200,000
Maximum Voltage Rating Wire Range (based on 75° C wire) Wire Type Lug Termination Clip Material
Temperature Rating Fuse Size (Dia. x Length) AIC Rating in accordance with UL512
File E40747 / Guide IZLT2 Certifications ¨
File E40747 / Guide IZLT
File 070360 Class 6225-01
¨
RoHS Compliant
RoHS Compliant Marked
Marked Flammability Rating
File 070360 Class 6225-01
UL94V-0
UL94V-0
UL94V-0
One Pole Blocks Catalog Number Dimensions (D) x (H) x (W)
9080FB1611M
9080FB1611CC
9080FB1611J
1.29 x 3.13 x 0.85 in.
1.29 x 3.13 x 0.85 in.
1.95 x 3.38 x 1.16 in.
32.8 x 79.5 x 21.6 mm
49.5 x 85.7 x 29.4 mm
32.8 x 79.5 x 21.6 mm Two Pole Blocks
Catalog Number Dimensions (D) x (H) x (W)
9080FB2611M
9080FB2611CC
9080FB2611J
1.29 x 3.13 x 1.60 in.
1.29 x 3.13 x 1.60 in.
1.95 x 3.38 x 2.20 in.
32.8 x 79.5 x 40.6 mm
49.5 x 85.7 x 56.0 mm
32.8 x 79.5 x 40.6 mm
Three Pole Blocks Catalog Number Dimensions (D) x (H) x (W)
9080FB3611M
9080FB3611CC
9080FB3611J
1.29 x 3.13 x 2.35 in.
1.29 x 3.13 x 2.35 in.
1.95 x 3.38 x 3.25 in.
32.8 x 79.5 x 59.7 mm
32.8 x 79.5 x 59.7 mm
49.5 x 85.7 x 82.5 mm
9080FBDIN3
9080FBDIN3
DIN 3 Track Mounting is standard.
DIN 3 (35 mm) Track Adapter
© 1993 - 2009 Schneider Electric All Rights Reserved
13 04/2009
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Terminal Blocks Fuseholder Approximate Dimensions 250 V, 30 and 60 A 30 A .22/5.6 DIA. HOLE THRU 4 PLACES
1.25 [31.8]
.33 [8.4]
1.25 [31.7]
.22 [5.7]
2.50 [63.5]
1.91 [48.5]
1.12 [28.4]
2.95 [74.9]
.82 [21]
.82 [21]
.82 [21]
1.38 [35.1]
.53 [13]
1.38 [35.1]
.53 [13]
1.38 [35.1] .53 [13]
FB2211 FB2211R
FB1211 FB1211R
3.00 [76.2]
30 A
250 V
3.00 [76.2]
30 A
250 V
3.00 [76.2]
.19 [4.8]
.75 [19]
1.50 [38.1]
1.50 [38.1]
.50 [13]
250 V 30 A
.22/5.6 DIA. HOLE THRU 2 PLACES
.22/5.6 DIA. HOLE THRU 2 PLACES
FB3211 FB3211R
60 A .218/5.54 DIA. C BORE.400/10.16 DIA. X .63/16 DEEP
250V. 60A.
1.24 [31.4]
4.83 [123]
250V. 60A.250V. 60A.
1.48 [37.7]
.49 [12]
.50 [13]
.50 [13]
.49 [13]
2.86 [72.7]
1.24 [31.4]
2.01 [51.1]
.50 [13] 1.33 [33.7]
.01 [.3]
1.33 [33.7] 4.23 [108]
2.01 [51.1]
.62 [16]
2.01 [51.1]
.62 [16]
FB2221 FB2221R
4.83 [123]
1.21 [30.8]
1.21 [30.8]
FB1221 FB1221R
250V. 60A.250V. 60A.250V. 60A.
1.80 [45.8]
1.33 [33.7]
1.21 [30.8]
4.83 [123]
1.80 [45.8]
1.80
[45.8]
.49 [13]
1.24 [31.4]
.62 [16]
FB3221 FB3221R
Dimensions:
© 1993 - 2009 Schneider Electric All Rights Reserved
in. [mm]
21 04/2009
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Terminal Blocks Fuseholder Approximate Dimensions 600 V, 30 A 1 Pole .85 [21.6]
.375 [9.5]
2 Pole 1.60 [40.6]
.750 [19.1]
30 A 3 Pole 2.35 [59.7] 1.500 [38.1]
1.56 [39.6] TYP.
3.13 [79.5]
.24 [6.1]
.42 [10.6]
.42 [10.6]
.750 [19.1]
.172 x .218 SLOTS TYP. [4.4] x [5.5]
.50 [13]
FB1611M
FB2611M
.85 [21.6]
1.60 [40.6]
.375 [9.5]
1.290 [32.8]
FB3611M
.750 [19.1]
2.35 [59.7] 1.500 [38.1]
1.56 [39.6] TYP.
.24 [6.1]
3.13 [79.5]
.42 [10.6]
.42 [10.6]
.750 [19.1]
.172 x .218 SLOTS TYP. [4.4] x [5.5]
.50 [13]
FB1611CC
FB2611CC
1.290 [32.8]
FB3611CC
Dimensions:
© 1993 - 2009 Schneider Electric All Rights Reserved
in. [mm]
23 04/2009
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Terminal Blocks Fuseholders Approximate Dimensions 600 V, 30A and 60 A 30 A .20/5.08 DIA. THRU
.265 [6.7] DIA. THRU
.265 [6.7] DIA THRU C'BORE .50 [12.7] DIA. X .44 [11.8] DP.
.265 [6.7] DIA THRU C'BORE .50 [12.7] DIA. X .44 [11.8] DP.
C'BORE SLOT .50 [12.7] X .94 [23.8] X .44 [11.2] DP.
.34 [8.7]
600V 30A
3.13 [79.4]
600V 30A
6.25 [159]
3.13 [79.4]
6.25 [159]
3.13 [79.4]
600V 30A
6.25 [159]
.31 [7.9]
1.56 [39.7]
.51 [13]
.62 [16]
.38 [9.7]
1.63 [41.4]
.62 [16]
.25 [6.5]
1.56 [39.6] 2.94 [74.7]
1.13 [28.6]
.62 [16] 3.13 [79.2]
.03 [.8]
4.25 [108]
1.13 [28.6]
1.13 [28.6]
1.69 [42.9]
1.69 [42.9]
.69 [18]
.69 [18]
.69 [18]
FB1611 FB1611R
3.51 (89.2)
1.95 (49.5)
1.69 [42.9]
FB3611 FB3611R
FB2611 FB2611R 60 A
.281 D. (7.1)
1.56 [39.7]
1.56 [39.7]
Dimensions:
in. [mm]
5.08 (129)
3.12 (79.2)
6.75 (171.4)
.50 D. (12.7)
1.81 (46)
.62 (15.7)
.66 (16.8)
1.56 (39.6) 1.56 1.29 (39.6) (32.8)
3.12 (79.2)
3.12 (79.2)
2.12 (53.8) .27 (6.8)
FB1621 FB1621R
.77 (19.6)
FB2621 FB2621C
FB3621 FB3621R
24 04/2009
© 1993 - 2009 Schneider Electric All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com