STEP 1

Download the SMART Service app to your mobile device. This free app is available for download on the App Store or by scanning the QR code below. The app is compatible with these devices:

STEP 2

Launch the SMART Service app on your mobile device.

SMART Service App iPad® 3 or newer

iPhone® 4S or newer

STEP 3

STEP 4

Power on the sensors with a quick press of the black buttons. The flashing LED indicates the sensor is on.

Link your mobile device to the sensors by touching the low energy Bluetooth® signal symbols.

STEP 5

Confirm that superheat/subcooling readings are indicated on your mobile device.

R-134a

SUPERHEAT

SUBCOOLING

––––

––––

LOW SIDE

HIGH SIDE

STEP 6

Set your system preferences.

R-134a

SUPERHEAT R-134a

SUPERHEAT

SUBCOOLING

––––

––––

LOW SIDE

0.0 psig 75°F

STEP 7

Select the system refrigerant.

R-407A

SUPERHEAT

SUBCOOLING

–REFRIGERANT ––– R-134a

R-404A

0.0 psig R-407A 75°F

––––

HIGH SIDE

0.0 psig 75°F

SUBCOOLING

–SETTINGS –––

Pressure PSIG / Bar

0.0 psig 75°F

Temperature °F / °C

HIGH SIDE

0.0 psig 75°F

STEP 8

Attach sensors to your system.

––––

PSIG °F

HIGH SIDE

0.0 psig 75°F

SMART SERVICE TOOLS Wireless Temperature and Pressure Sensors SMART Service Tools are lightweight wireless sensors that conveniently sync with a mobile app, enabling you to read a system’s real-time pressure and temperature without using hoses or manifold gauges. • Simple, wireless, app-supported readings with hose-free connections • Compact, convenient and can be used with most refrigerants and oils   • Instant data calculations plus export and storage capabilities Contact Parker’s technical support team at 636-392-3906 if you need assistance setting up your SMART Service Tools.

⚠WARNING – USER RESPONSIBILITY Failure or improper selection or improper use of the products described herein or related items can cause death, personal injury and property damage. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. For safety information see the Safety Guide at www.parker.com/safety or call 1-800-CParker. OFFER OF SALE The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” available at www.parker.com. FOR USE ON AIR CONDITIONING and REFRIGERATION SYSTEMS ONLY. App Store, iPad and iPhone are registered trademarks of Apple Inc. © 2015 Parker Hannifin Corporation.

WHAT’S IN THE

BOX.

Parker Hannifin Corporation 2445 South 25th Avenue, Broadview, IL 60155 USA phone 708 681 6300 fax 708 681 6306 www.ParkerRealSolutions.com www.parker.com/refspec

STEP 9

Monitor system settings. If needed, record and send data, change units of measure, etc.

STEP 10

Remove sensors from the system. R-407A

RECORDED SESSIONS Record Residence LOW SIDE R-407A Smith HIGH SIDE 7s on Aug. 8, 2014

STEP 11

To power down the sensors, press and hold the black buttons until LED flashes quickly.

STEP 12

Place your SMART Service Tools back in the case.