SITE PLAN AWS

Report 0 Downloads 130 Views
39,843 SF (30.6%)

35 FEET

NO LIMIT

0.3060

1.0

BY DATE 13455 NOEL ROAD, SUITE 700, DALLAS, TX 75240 PHONE: 972-770-1300 FAX: 972-239-3820 WWW.KIMLEY-HORN.COM TX F-928

No.

CONCRETE WALL PANELS PAINTED WHITE, LARGE FORMAT PORCELAIN WALL TILE, CLEAR GLASS AND ANODIZED ALUMINUM STOREFRONTS

LEGEND

CITY SETBACK LINE

6

PARKING STALL COUNT

LS

LANDSCAPE AREA

BFR

BARRIER FREE RAMP

SW

SIDEWALK DIRECTION OF TRAVEL PROPOSED 4" SIDEWALK PROPOSED 5" CONCRETE PAVEMENT (LIGHT) PROPOSED 6" CONCRETE PAVEMENT (MEDIUM) PROPOSED 7" CONCRETE PAVEMENT (HEAVY) PROPOSED 10" CONCRETE PAVEMENT (PUBLIC)

NOTES 1.

ALL FIRE LANES SHALL HAVE A MINIMUM OF 14-FEET HEIGHT CLEARANCE FROM ALL LANDSCAPING.

2.

MINIMUM TURNING RADIUS FOR FIRE LANES ARE 26-FEET INTERIOR AND 50-FEET EXTERIOR.

3.

ALL DISTANCES SHOWN ARE FROM FACE OF CURB.

4.

BUILDING TO BE SPRINKLED. REFERENCE MEP PLANS FOR DETAILS.

BENCHMARK LIST BM#1 (CITY OF THE COLONY MONUMENT NO. 3 - 1/4-INCH ALUMINUM DISC FOUND IN CONCRETE RIP-RAP BETWEEN THE WEST BOUND SERVICE ROAD OF STATE HIGHWAY NO. 121 AND THE WEST BOUND THROUGH LANES OF STATE HIGHWAY NO. 121 OVER BURLINGTON NORTHERN/SANTA FE RAILROAD, APPROXIMATELY 11,700 FEET NORTHEAST OF INTERSECTION OF STATE HIGHWAY NO. 343. ELEV= 574.83 BM#2 SQUARE WITH "X" CUT SET IN THE NORTHWEST CORNER OF A CONCRETE CURB INLET, NORTH CURB OF WEST BOUND SERVICE ROAD

120260

EASEMENT

P.E. No.

PROPERTY LINE

Date NOVEMBER 2017

PROPOSED FIRE LANE

DSA

FL

DRAWN BY

FL

DANIEL P. GALLAGHER

This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.

REVISIONS

HEIGHT OF BUILDING

2017 KIMLEY-HORN AND ASSOCIATES, INC.

10

LOCATED IN THE NORTHWEST RIGHT-OF-WAY OF STATE HIGHWAY NO. 121. ELEV= 617.09 BM#3 SQUARE WITH "X" CUT SET IN THE NORTHWEST CORNER OF A CONCRETE CURB INLET ON THE NORTH SIDE OF A CONCRETE DRIVEWAY, 345 FEET NORTHEAST FROM THE NORTHEAST RIGHT-OF-WAY OF MORNING STAR DRIVE 470 FEET NORTHEAST FROM THE INTERSECTION OF THE NORTHEAST RIGHT-OF-WAY OF MORNING STAR DRIVE AND THE NORTHWEST RIGHT-OF-WAY OF STATE HIGHWAY NO. 121, 15 FEET NORTHEAST OF A FIRE HYDRANT. ELEV= 616.33

GEOTECHNICAL ENGINEERING REPORT PREPARED FOR: PARAGON INDUSTRIES II PREPARED BY: ALPHA TESTING, INC. REPORT: ALPHA REPORT NO. G170968

(MAY 22, 2017)

SHEET NUMBER

C-02

DPG

1

CHECKED BY

NUMBER OF STORIES

TEXAS

ALLOWED

THE COLONY

PROPOSED

EXTERIOR MATERIALS

EPSG32614_Date20170123_Lat33.079319_Lon-96.861059_Mpp0.075 : gallagher_dan : RGA Logo : EPSG26914_Date20170123_Lat33.079391_Lon-96.861462_Mpp0.075 : xSite : xbdr24x36 : xExUtil : xSurvey : xPav : xView : xEsmt : xUtil 11/2/2017 8:59 AM OSBURN, TYLER 11/2/2017 9:07 AM K:\DAL_Civil\64511801 - Bedrosian The Colony\4_Design\CAD\PlanSheets C-SITE.dwg

PIER AND BEAM

FOUNDATION TYPE

TOTAL FLOOR AREA RATIO

IMAGES XREFS LAST SAVED PLOTTED BY DWG PATH DWG NAME

619.00 FEET

FINISHED FLOOR ELEVATION

Engineer

PARKING REQUIRED FOR LOW VOLUME RETAIL IS 2.5 SPACES PER 1,000 SF OF GFA (1 SPACE PER 400 SF)

BUILDING COVERAGE

TAO

1 SPACE

DESIGNED BY

1 SPACE

26,689 SF/ 0.61 AC.

BEDROSIANS TILE AND STONE

OFF-STREET LOADING AREA

IMPERVIOUS AREA

AS SHOWN

1 SPACE

SCALE

1 SPACE

H

PREPARED FOR

ACCESSIBLE VAN PARKING

130,214 SF/ 2.99 AC

SITE PLAN

3 SPACES

LOT AREA

FOR REVIEW ONLY

3 SPACES

NO RT

COMMERCIAL, PD-16, GATEWAY OVERLAY DISTRICT

NOT FOR CONSTRUCTION PURPOSES

Call before you dig.

ACCESSIBLE AUTO PARKING

ZONING

GRAPHIC SCALE IN FEET 15 30 60

NOVEMBER 2017

Know what's below.

39,843SF / 400 100 SPACES

0

DATE

WARNING: EXISTING UTILITIES SHOWN ARE BASED ON AVAILABLE RECORD DRAWINGS AND ABOVE GROUND FIELD SURVEY DATA, THEREFORE THERE MAY BE UTILITIES PRESENT THAT ARE NOT SHOWN ON THESE CONSTRUCTION PLANS. CONTRACTOR TO FIELD VERIFY PRESENCE AND EXACT LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION AND USE CAUTION DURING CONSTRUCTION. NOTIFY ENGINEER AND OWNER OF ANY DISCREPANCIES.

100 SPACES

RETAIL, LOW VOLUME

PROPOSED USE

THE COLONY DEVELOPMENT

TOTAL PARKING

REQUIRED

KHA PROJECT 064511801

PROVIDED

SITE DATA SUMMARY

SITE PLAN SP17-0022

PARKING SUMMARY TABLE