Skylark Contour® C • L ® Dimmer Dimmer for CFL, LED, Halogen, and Incandescent dimmable bulbs. Features • On / off rocker switch with a captive linear-slide dimmer for a standard designer wallplate opening • HEDT Technology: Advanced LutronR dimming circuitry designed for compatibility with most high efficacy light bulbs • ULR Listed to control: — Dimmable compact fluorescent (CFL) with integrated ballast — Dimmable LED with integrated driver — Halogen — Incandescent • Low-end adjustment to accommodate a wide range of bulbs
Select light level with slider
• 100% factory tested Switch on (to selected
Application Requirements • When dimming CFLs or LEDs, only bulbs marked or rated as DIMMABLE may be used. • For a complete list of compatible DIMMABLE CFLs and LEDs please visit www.lutron.com/dimcflled. For questions call 1.800.523.9466. • Some DIMMABLE CFLs and LEDs require a minimum number of bulbs for proper operation. For details and a list of bulbs, please visit www.lutron.com/dimcflled.
light level), and off * Wallplate sold separately
Model Number CTCL-153P-XX1
Single pole / 3-way2
1
“XX” in the model number represents color/finish code; see "Colors and Finishes" on next page.
2
For 3-way and 4-way switching, use ClaroR switches or other mechanical switches.
Job Name:
Job Number:
S P E C I F I C AT I O N S U B M I T TA L Model Numbers:
Page
Skylark Contour®
C • L ® Dimmer
Wallbox Controls 369683a 2 12.03.12
Specifications
Dimensions
0.30 in (7.6 mm)
Regulatory Approvals • ULR Listed to US and Canadian safety requirements UL1472 / CSA C22.2 184.1 • NOM 4.69 in (119 mm)
Power and Ratings • 120 V 60 Hz • 150 W dimmable CFL/LED or • 600 W Incandescent/Halogen or • Mixed bulb type per Multigang and Mixed Bulb Type Ratings table (see page 3)
2.94 in (75 mm)
2.75 in (70 mm)
1.31 in (33 mm)
Note: Requires a U.S. wallbox 2` in (64 mm) deep minimum.
Environment • For indoor use only. • Operating temperatures 32 °F to 104 °F (0 °C to 40 °C). Performance • • • • •
Power-failure memory Captive linear slider Electrostatic discharge tested Precise color matching Mechanical air-gap switch to disconnect load power Warranty
• 1 Year Limited Warranty For additional Warranty information, please visit http://www.lutron.com/TechnicalDocumentLibrary/ 369-119_Wallbox_Warranty.pdf
Job Name:
Job Number:
S P E C I F I C AT I O N S U B M I T TA L Model Numbers:
Colors and Finishes Gloss Finishes Add color/finish code to model # Example: CTCL-153P-WH WH White IV Ivory AL Almond LA Light Almond GR Gray BR Brown BL Black
Page
Skylark Contour®
C • L ® Dimmer
Wallbox Controls 369683a 3 12.03.12
Multigang and Mixed-Bulb-Type Ratings When installing more than one Dimmer in the same wallbox, it may be necessary to remove some side sections prior to wiring (see diagram). Removal of Dimmer side sections may reduce maximum wattage, as shown in the chart below. Mixing bulb types (using a combination of CFL/LED, and Incandescent/Halogen bulbs) will also affect the maximum ratings, as shown in the chart below. *EXAMPLE: If one set of side sections is removed and you have two 24 W CFL bulbs installed (Total CFL Wattage = 48 W), you may add up to 300 W of incandescent or halogen lighting. Do not remove outside sections
Each Dimmer has inside sections removed
Middle Dimmer has two side sections removed
Total CFL/LED Wattage Installed
Maximum Allowable Incandescent/Halogen Wattage
(Wattage per bulb x # of bulbs)
0W 1 W – 25 W 26 W – 50 W 51 W – 75 W 76 W – 100 W 101 W – 125 W 126 W – 150 W
Job Name:
Job Number:
No sides removed
+ + + + + + +
600 W 500 W 400 W 300 W 200 W 100 W 0W
S P E C I F I C AT I O N S U B M I T TA L Model Numbers:
1 side removed
500 W 400 W 300 W 200 W 100 W 50 W 0W
2 sides removed
400 W 300 W 200 W 100 W 50 W 0W 0W
Page
Skylark Contour®
C • L ® Dimmer
Wallbox Controls 369683a 4 12.03.12
Operation (View with wallplate removed) Lever-type Adjustment Dial 1
Switch
Turns lights ON and OFF.
2
Slider
3
Up (clockwise) Increases brightness
Up Increases light level
3
2 1
Adjustment lever
Sets low end dimming limit.
Controls light level.
Down Decreases light level IMPORTANT: Set slider to bottom before adjusting dimming range. Down (counter-clockwise) Decreases brightness
OR
Wheel-type Adjustment Dial 3
Adjustment dial
Sets low end dimming limit. Up (clockwise) Decreases brightness
Down (counter-clockwise) Increases brightness
Job Name:
Job Number:
S P E C I F I C AT I O N S U B M I T TA L Model Numbers:
Page
Skylark Contour®
C • L ® Dimmer
Wallbox Controls 369683a 5 12.03.12
Wiring Diagrams Single-Pole Wiring Dimmer
Line/ Hot Hot
Dimmer
Black Black
Red
Red
Red/White
Red/White
120V V~ 120 60 60HzHzFeed
Lighting Load
Green
Green
Lighting Load
Neutral
Neutral
3-Way Wiring Dimmer Line Side Dimmer
Line/ Black Hot Control
*
Red
Line Side Hot
Black
Dimmer Load Side 3-Way Switch Line/ Hot ** * Control
3-Way Switch **
Load Side
3-Way Switch
Dimmer Red/White Red
*
Hot
***
Green Red/White
120 V 60 Hz Feed
Lighting Load OR
Green
Neutral
*** Red/White
Black
Green
120 V 60 Hz Feed
Lighting Load
Black
Dimmer
* Red/White Red
120 V~ 60 Hz
OR
120 V~ 60 Hz
3-Way Switch
Dimmer Red
Lighting Load
Green Lighting Load
Neutral
4-Way Wiring * or Copper/Black screw terminal ** or Brass/Gold screw terminal *** or Green screw terminal
Dimmer Line Side 4-Way † Switch
Dimmer
Line/ Hot Black ntrol
Red
*
3-Way Switch **
*
†
**
e Side 120 V~ 60Black Hz
4-Way Red/White *
Dimmer
**
Switch
3-Way * Switch
Lighting Load
Red
Green
***
***
Red/White
Neutral Feed
3-Way Switch
ral
Line/
4-Way † Switch
**
*
OR*
3-Way Switch
*
4-Way * Switch
ntrol Hot d Side 120 V~ 60 Hz
Neutral Feed
Job Name:
Job Number:
Dimmer **
Red
**
Red/ Dimmer White
Red
***
***
Note for 4-Way Wiring: Dimmer must be installed Line Side or Load Side. It cannot be installed in the 4-way location.
Lighting Load
OR
Green
Dimmer Load Side
Red/ White
Please refer to switch instruction sheet for proper wiring.
Black
Black
Lighting Load
Green
Green