T-24 NOTES: 1. ELECTRONIC BALLAST IF 13 WATTS OR MORE. 2. RECESSED CANS IN INSULATED CEILINGS IC TYPE AND CERTIFIED AIRTIGHT. 3. SWITCH ALL HIGH-EFFICACY LIGHTS SEPARATELY FROM LOW-EFFICACY LIGHTS. 4. ALL LIGHTS SHALL BE HIGH EFFICACY (15 WATTS OR LESS PROVIDE 40 LUMEN PER WATT, 15-40 WATTS PROVIDE 50 LUMENS PER WATT AND OVER 40 WATTS PROVIDE 60 LUMEN PER WATT) UNLESS: KITCHENS: 50% OF THE TOTAL WATTAGE FOR KITCHEN LIGHTING TO BE HIGH EFFICACY (e.g. FLUORESCENT). - GARAGE LAUNDRY, UTILITY ROOMS: ALL FIXTURES MUST BE HIGH EFFICACY. ALL MUST BE CONTROLLED BY VACANCY SENSORS. BATH ROOMS: AT LEAST ONE FIXTURE MUST BE HIGH EFFICACY. ALL LOW EFFICACY FIXTURES MUST BE CONTROLLED BY VACANCY SENSORS. - ALL OTHER ROOMS: HIGH EFFICACY OR PROVIDE DIMMER CONTROLS FOR ALL HARDWIRED FIXTURES. - OUTDOOR LIGHTING TO BE HIGH EFFICACY OR CONTROLLED BY A MOTION SENSOR WITH INTEGRAL PHOTO-CONTROL. 5. ALL HIGH EFFICACY LUMINARES (INCLUDING RECESSED CAN FIXTURES) SHALL CONTAIN PIN-BASED SOCKETS UNLESS SPECIFICALLY APPROVED BY THE ENERGY COMMISSION. 6. ALL LIGHTING FIXTURES TO BE SELECTED BY OTHERS. 7. ALL POWER AND LIGHTING OUTLETS IN FAMILY ROOMS, PARLORS, LIBRARIES. DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, HALLWAYS AND SIMILAR AREAS ARE TO BE PROTECTED BY A COMBINATION AFCI BREAKER. KITCHENS, BATHROOMS AND BASEMENTS ARE EXEMPT FROM THIS REQUIREMENT. [CEC 210.12(B)]. 8. COMBO SMOKE/CARBON MONOXIDE DETECTORS TO BE HARD WIRED TO 120V. CIRCUIT AND HAVE EMERGENCY BATT. BACK-UP. CARBON MONOXIDE DETECTORS SHALL BE UL 2034/2075 LISTED. INTERLOCK.