application
electrical
• Designed for modern lamp/ballast systems. High lumen lamps and high efficiency ballasts are recommended to minimize energy consumption without sacrificing light levels. • Energy savings approaching 1/3 are possible compared to conventional T8 parabolic luminaires, while maintaining IES recommended light levels. • Lighting power densities as low as 0.6 Watts/square foot are possible while maintaining recommended light levels. • 3" nominal housing depth requires less plenum space than traditional parabolics.
• Lamp/ballast systems are available offering electrical system efficacy ratings up to 90 Lumens/Watt. • Total luminaire efficacy as high as 77 LPW. • Step dimming ballasts can be switched to 50% (or less) input power for energy savings to meet most energy codes while maintaining symmetrical illumination. • UL listed for damp locations. Canadian certified optional. • Self-contained fluorescent emergency power packs can be incorporated, UL listed for dry locations. • Some models with multiple ballasts or emergency ballasts will be supplied with a top mounted ballast box which will increase the height of the luminaire.
construction • Housing is multi-stage phosphate treated for maximum corrosion resistance and finish coat is high reflectance baked white enamel. • Smooth rolled edges on all four sides for easy handling. • Integral baffling system to prevent light leaks. • Die-formed one piece housing including end plates has stiffening embosses and provides increased rigidity. • T-bar grid clips are integral to luminaire, no extra parts required. Designed for use with standard grid ceiling members, 1-1/2" maximum height. • Embosses with holes provided in housing for screwing to T-bar if desired.
268-PLV Paralouver Recessed 2X2 Energy Select 2 Lamp T5, T5H0 or T8 6 Cell 2 lamp energy saving replacement for standard parabolics
enclosure • 6 cell louver is available with ribbed or flat cross baffles and creates a controlled amount of light in the upper spaces of the room to eliminate “cave effect” and create uniform illumination. • Louver features a high reflectance diffuse white powder-coat finish. • Opposable spring loaded latches are standard for easy operation and consistent retention. • Can be hinged and latched from either side.
Specifier’s Reference Project Type Model No. Comments
Green Choice: 2ESG217-23RMW-UNV-1/2EBHE-LPT835HL 2
ES
Width
2 – 2'
2 Ceiling Type
G – Grid F – Flange
Family
ES – Energy Select
– Lamp Type/Wattage
– Louver Finish
(not included) 2
Louver Configuration (Cells Wide x Cells Long) 23 – 2 x 3
–
Ballast Configuration
Options
CM – Canadian Market F1 – Installed flex, 3/8" diameter, 18 gauge, 3 wire, 6' Ballast Type F2 – Installed flex, 3/8" diameter, 18 gauge, 4 wire, 6' EB95 – 28WT5 electronic ballast, E1* – DEB-1 emerg. ballast, CF/T8, .95 ballast factor 350-450 lumens EB115 – 14WT5/28WT5 electronic ballast, E5* – DEB-5 emerg. ballast, CF/T8, 1.15 ballast factor 1100-1400 lumens EBSD95 – 14WT5/28WT5 electronic step E7* – DEB-7 emerg. ballast, CF/T8, dimming ballast, .95 ballast factor 430-700 lumens EBSD115 – 14WT5/28WT5 electronic E7LP* – DEB-7LP emerg. ballast T8/T5/T5HO, 430-700 step dimming ballast, Voltage lumens 1.15 ballast factor E6LP* – DEB-6LP emerg. ballast, T8/T5/T5HO, 750-1325 120 EBSD80 – 54WT5HO electronic step lumens 277 dimming ballast, .80 ballast factor GLR# – Fusing, fast blow (# = number of ballasts) 347 EBD – Electronic dimming ballast LPT730 – Installed T8 lamps, 70+ CRI, 3000K UNV – Universal EB – Electronic ballast, std. LPT735 – Installed T8 lamps, 70+ CRI, 3500K voltage, ballast factor LPT741 – Installed T8 lamps, 70+ CRI, 4100K 120-277 EBL – T8 electronic ballast, LPT830HL – Installed T8/T5 hi lumen lamps, volt low ballast factor 80+ CRI, 3000K EBH – T8 electronic ballast, LPT835HL – Installed T8/T5 hi lumen lamps, 80+ CRI, 3500K hi ballast factor LPT841HL – Installed T8/T5 hi lumen lamps, 80+ CRI, 4100K EB10I – T8 electronic ballast, LPT830 – Installed CF/T8/T5/T5HO lamps,