Standard Industrials

Report 2 Downloads 135 Views
Industrials

Standard Industrials

L LA

tified ballast is standard. Sound rating depends on lamp/ballast combination.

Intended Use For mounting heights up to 16' requiring low to medium light levels. Ideal for light duty areas, utility, storage rooms or retail.

Wiring & Electrical - AWM, TFN or THHN wire used throughout, rated for required temperatures. Mounting - For unit or row installations, surface or suspended mounting.

Features

Listings - UL Listed (standard). NOM Certified (see options). These models not available in Canada.

Solid top reflector or 8% uplight is available. Sturdy combination reflector and channel cover secured by captive quarterturn latch for easy access to wireway. Combination endplate/channel connector supplied with each fixture. High-gloss backed white enamel finish. Reflector is painted after fabrication. Available in tandem wired lengths. Accepts plug-ins for 1, 2 or 3 primary circuits

For product details and performance data, see the FLUORESCENT binder or the on-line catalog at www.lithonia.com.

Ballast - Thermally-protected, resetting, Class P, HPF, non-PCB, UL listed, CSA-cer-

Example: L240120ES

Ordering Information

Series L

Number of lamps 17

17WT8I24")

120

20

20WT12(24")'

277

Not included.

32

32WT8I48")

347

40

40W 112(48")

48

38W Slimline (48")

8% uplight For tandem double-length unit, add prefix T. Example: TL

48T8HO 96 96T8 96T8HO

Options/

Voltage

1 2

Solid reflector

LA

Lamp type

MVOLT 2 Others available.

Accessories NOM NOM Certified For additional options and accessories, see below and pa 103.

44WT8(48") 75W Slimline (96") 59W T8 Slimline (96") 86W T8 380mA (96")

Availability and Dimensions Lamps per Cross

per

Lamp

Width 3

Depth 3

Length 3

Section

Fixture

Type

in.(cm)

in. (cm)

in. (cm)

Series

L, LA

L, LA TL , TLA

L, LA

Lamps

1

1

17, 20'

12 (30.5)

4 (10.2)

24 (61.0)

2

2

17, 20'

12 (30.5)

4 (10.2)

24 (61.0)

1

1

32, 40, 48

12 (30.5)

4 (10.2)

48 (121.9)

2

2

32, 40, 48, 48T8HO

12 (30.5)

4 (10.2)

48 (121.9)

1

2

32, 40, 48, 48T8HO

12 (30.5)

4 (10.2)

96 (243.8)

2

4

32, 40, 48

12 (30.5)

4 (10.2)

96 (243.8)

1

1

96, 96T8, 96T8HO

12 (30.5)

4 (10.2)

96 (243.8)

2

2

96, 96T8, 96T8HO

12 (30.5)

4 (10.2)

96 (243.81

1. Standard Packaging* Fixture ships complete in unit cartons. To order, use single catalog number as shown. Ordered:

NOTES: 1 Specify ballast option HPF or LPF for 20W. 2 Multi-Voltage ballast operates on any input within the voltage range 120V-277Vinclusive at 50HZor60HZ. Available as option in the GEB10IS category for 1-4T8 lamps up to 48" in length only. 3 For detailed mounting information consult the product specification sheets.

f* L/THON/A

ORDERING/PACKAGING OPTIONS - To accommodate the product's physical configuration as well as a range of customer handling and processing needs, alternative ordering/packaging methods are available.

UGHT/NG

Drawings for dimensional detail only. May not represent actual mechanical configuration. Dimensions are shown in inches (centimeters).

(Qty 21] L240 120 ES

Shipped as: (21] I 2 40120 ES - housing & reflector 2. Job Packaging* Fixture ships housings and reflectors separately in job packs of four. To order, use single master catalog number as shown. Ordered:

(Qty 21) L 2 40 120 ES J4

Shipped as:

(20) LCC 2 40 120 ES J4 - housing (20) LR48 J4 - reflector 111 L 2 40120 ES - housing & reflector

* Job-site load of fixtures on pallets, wrapped without individual cartons, is available. AddJP to fixture catalog number for this option. Contact factory for fixtures per pallet number.

Fluorescent Options

Miscellaneous Options PW - Prewiring Option (Troffers only)

Factory-installed flexible cable, wired into fixture through access plate.

Complete range of prewired whips for every installation requirement.

%" cable with snap-in connectors standard. Vf cable optional.

Ordering Information Develop 6- or 7-digit suffix as explained below. Add suffix to fixture catalog number.

Choice of wire gauge. Up to five wires, including one neutral (white) and one ground (green) - permits multi-level switching.

Example: 26T8 3 32 A12 120 PWS1836 (%" flex cable with three No. 18 AWG leads B, W, GR, cable 6' long.)

Family

PW

Cable

Prewire

(blank)

S

1

/2" dia.

Ready to connect to J-box.

Number of wires

Wire gauge

3

12,14,18

4 5

%" dia.

T-Bar Safety Clips Screw-on Clips (Troffers only) LATC Hold-down clips to secure troffer to T-bar. Field installed. Attach by screwing to fixture end plates. Four furnished per fixture.

Cable length 6

6 feet

Ballast Options CW

Cold-weather ballast; 0°F starting for RS slimline lamps and some T8 lamps. CW20 Cold-weather ballast; -20°F starting for HO and PG lamps. GEB

GEB10IS

GEB10RS

Example: 2PM4 G B 3 32 18LD 120 GEB LATC

1 circuit 2 circuits 3 circuits

Electronic ballast, maximum 20% THD. Factory choice; see page 593 for specification and ordering information. Electronic ballast, instant start maximum 10% THD. Factory choice; see page 593 for specification and ordering information. Electronic ballast, rapid start, maximum 10% THD. Factory choice; see page 593 for specification and ordering information.

Construction for Fire-Rated Ceilings (Troffers only) FR Lithonia fluorescent troffers are UL Listed and are compatible with UL Fire-Rated Ceiling assemblies. Upon request for the FR option, the FR label is applied to the back of the housing. Label states: This troffer is specially designed to be installed in fire-rated or insulated ceilings.

Example: 2GT8 4 32 A12 120 GEB FR

NOTE: Not applicable for CSA or NOM listings. Some dimming and some compact lamp troffers may require electronic ballasts.

Example: C 2 96 120 CW

NOTE: Safety clips may be used on fixtures with integral Tbar clips if additional means of attachment are required. Snap-on Clips (Troffers, RR, CRR) HTC Hold-down clips to secure troffer to T-bar. Four furnished per fixture.

Fusing One per ballast furnished. Fusing not recommended for use with 277V magnetic dimming ballasts. Internal Fusing BKTK GLR GMF

Internal fast-blow fuse. For use in 347V fixtures. Internal fast-blow fuse. Internal slow-blow fuse.

External Fusing (Strips and open industrials only) GLRX GMFX

f* L/THON/A

L/GHT/NG

External fast-blow fuse. External slow-blow fuse.

Fluorescent Lighting