Unite your power network
StruxureWare Power Monitoring software Maximize operational efficiency, optimize power distribution, and improve bottom-line performance
Healthcare
Data Centers and Networks
Make the most of your energy
SM
Scalable power management software that unites your power network Today, as a facility manager, you are pushed to the limit with demands on your time, staff reductions, increasing responsibilities, complexity of systems, CapEx and OpEx pressures. At the same time, critical business operations depend on your ability to maintain reliable operations, reduce energy costs, and get the most out of your electrical assets.
StruxureWare Power Monitoring brings your facility together
8%
StruxureWare™ Power Monitoring software is a complete, interoperable, and scalable supervisory interface dedicated to power monitoring that enables you to maximize operational efficiency, optimize your power distribution system, and improve your bottomline performance.
Your per-year energy losses without a power monitoring system in place
Real-time monitoring, alarming, and power quality analysis help you avoid critical conditions that can cause equipment failures and downtime. Additionally you gain the ability to track the consumption and cost of power, gas and other resources, then allocate those costs by building, department, or process. The software helps you uncover energy waste, unused system capacity, and shows new ways to extend equipment performance and life span. Plus, cuttingedge flexibility and compatibility let you extend your power management system at your own pace, and allow for an open system with the integration of third-party devices and systems. Achieve maximum efficiency with ready-to-use device drivers, preconfigured tables, views, and reports dedicated to power and energy management, saving thousands of engineering hours.
StruxureWare Power Monitoring Software A flexible, scalable architecture that collects data from your entire power system 2
Intuitive web interface display of any measured parameter
Integrate your entire facility and maximize your electrical network performance
Applications for your power management challenges Power availability and reliability
Energy efficiency
Verify the reliable operation of power equipment
Identify billing discrepancies
Ensure and indicate that operations are normal Proactively optimize electrical distribution network Monitor breaker status, trip counting, real-time voltage, transformers, ATS, generators, capacitor banks, and tap changers Stay alert to adverse trends; take corrective action when necessary
Improve response to powerrelated problems Verify normal activities and provide information to help proactively assess issues Quickly review events, trends, and load status before, during, and after a problem
Validate that power quality complies with the energy contract Analyze and verify metrics to ensure compliance with agreed-upon levels of quality
Electrical distribution monitoring Leverage existing infrastructure capacity and avoid over-building Reveal historical and current load patterns and hidden capacity Determine if existing infrastructure will accommodate new equipment
Support proactive maintenance to prolong asset life Real-time and historical data reveals relationships between equipment and the conditions affecting system stability
Validate utility bills, document errors, and measure energy contract compliance Identify false penalty charges and validate benefits of on-site generation
Measure efficiency, reveal opportunities, and verify savings
Up to 80K Annual facility cost of power quality problems
Measure and compare consumption across departments, processes, and industry KPIs to identify the optimal places for improvement or adjustment Confirm ROI for system improvements with advanced reporting and analysis
Allocate costs to departments or processes Collect, calculate, and report costs for buildings, departments, processes, shifts, lines, or equipment Reduce expenses, enable best practices, and validate all your conservation initiatives
Reduce peak demand, power factor penalties Identify locations of poor power factor and justify power factor improvement measures Automatically monitor capacitor banks and load tap changers Alert on demand levels, analyze trends to identify demand reduction, and load shifting opportunities
Participate in load curtailment programs Review historical patterns to build a curtailment plan to enable participation in utility programs Automate, aggregate load management to verify curtailment, coordinate backup systems, and ensure contract compliance Negotiate to reduce loads in response to utility curtailment requests
3
Expand your energy capabilities As your operations grow, your power monitoring system needs to be an integral part of your growth strategy. StruxureWare Power Monitoring software fits in with your strategy and expands its capabilities with flexible deployment options that meet the needs of your IT group. Whether supporting custom solutions and advanced requirements, or through its capability to communicate with third-party devices in your system, StruxureWare Power Monitoring adds value over the long term.
Designed for step-by-step investment Scalable, flexible architecture Grow to hundreds of metering points Integrate legacy and third-party devices Leverage and optimize existing infrastructure
Interoperable Share data with third-party SCADA, automation, building management, and accounting systems Open standards-based interoperability via ODBC, OPC, XML, Modbus®, and PQDIF
Historical trend analyses
Alarms and control functions
Real-time display of data
Network diagrams
Power quality analyses
Reports library
Local and remote workstations
Corporate network
Piped utilities (WAGES) Switching and mitigation equipment
4
Power distribution equipment
Loads, processes, or tenants
As scalable, reliable, and integrated as you need Real-time monitoring Dashboard displays Share information with your external stakeholders Display any parameter in your power network Kiosk or slide-show mode for flexible presentation options Combine metering of all utilities (WAGES)
Graphical and tabular displays Collect system-wide data, display, and perform calculations Customize views of your data Graphics templates and table libraries provide plug and play views of your facility
Attractive dashboard displays
Alarms and events Trigger on complex conditions, on-screen alarm notifications Log all relevant data and sequence of events for diagnosis Flag and avert potential problems Acknowledge alarms with authenticated web access and audit trails
Trend, analyze, and report Analyze data and power quality Trend any parameter to reveal demand peaks and track system-wide energy costs Identify patterns in operational usage trends Optimize network capacity and avoid over-building
Alarm and event displays
Power quality analyses Monitor events and waveform plotting system-wide Monitor harmonics, K-factor, crest factor, symmetrical components Diagnose and isolate PQ problems to increase reliability
Comprehensive reports Sixteen pre-configured report templates to get you up and running immediately Options for fully customized reports Manual, scheduled, or alarm/event-triggered distribution via email or web
Power quality analyses
5
Protect and support your investment 100%
Without monitoring and maintenance Optimized usage via automation
Efficient devices and installation
Energy Consumption
70%
Monitoring and maintenance
Time Up to 8% per year is lost without a monitoring and maintenance program
Up to 12% per year is lost without regulation and control systems
Investing in a power and energy monitoring system pays. It helps you manage your energy efficiently and gives you unique insight into energy-related costs, risks, and opportunities. Protect and optimize your investment by signing up for Schneider Electric™ Energy Management Services StruxureWare Power Monitoring software is an investment in your business, and you’ll want to protect it with a Schneider Electric Technical Service and Support agreement. It helps you maximize your investment and ensure you have a reliable power network both today and tomorrow.
Technical Support Contract As with all of our products, we offer the best experience and knowledge in the industry to help you with all of your power management support and maintenance needs. Best of all, you can clearly and simply choose your level of service.
Standard Support Standard Support is available with every PowerLogic™ System. If you have the time and the knowledge to doit-yourself, then we are happy to assist you with PowerLogic product installation and configuration questions.
Priority Support The Square D™ PowerLogic Priority Support program offers priority assistance by our senior technical support engineers. They can remotely connect to your system and resolve the issue while you observe or work on other tasks.
Premium Support Premium Support provides proactive support that improves the system performance, increases system utilization, and helps reduce the total cost of ownership.
6
Energy Management Life Cycle Schneider Electric’s energy and sustainability solutions support you at every stage of the energy management life cycle. Comprehensive energy management is a tremendous asset, allowing you to redirect resources to your core business.
Concern
Benefit
What is my Strategy?
Make a comprehensive plan that fits your goals, and chart your progress
How do I buy?
Negotiate the best terms with every supplier and minimize risk.
How do I control?
Monitor your operations to ensure reliability, uptime, power quality, and billing accuracy
How do I optimize?
Execute targeted efficiency projects with ROI that can be proven.
How am I performing?
Use robust support services and reporting software to ensure optimum performance
7
Part of the bigger picture Power monitoring can be simple
StruxureWare power and energy meters
Legacy power and energy meters
ION8650 series
ION8300/8400/8500
ION8600 series
ION7700
ION7550/7650 series
ION7500/7600 series
ION7550RTU
ION7550RTU
ION6200
ION7300 series (ION7300, ION7330, ION7350)
PM800 series (PM810, PM820, PM850, PM870)
ACM3720, ACM3710, ACM3300
PM700 series (PM710, PM750)
PowerLogic circuit monitors
PM1200
CM2000 series (CM2050, CM2150, CM2250, CM2350, CM2450)
EM1200, EM5600
CM3000 series (CM3250, CM3350)
PM210
CM4000 series (CM4150, CM4250, CM4000T
DM6200
PowerLogic branch circuit power meters
Circuit breaker trip units
BCPM (A, B, C models)
Micrologic™ A, P and H devices
Protective relays
PLC
Sepam series 10, 20, 40, 48, 80
Modicon™ Momentum M1 – TR (A8, D10, D16)
Limited edition (LE) drivers for download
Twido™ Modular PLC (D12,D28, D44)
Modbus-compatible devices and other devices through OPC
Schneider Electric USA 295 Tech Park Dr. LaVergne, TN 37086 Tel: 615- 287-3500 www.schneider-electric.com/us Document Number 3080BR1201
April 2012
©2012 Schneider Electric. All Rights Reserved. Schneider Electric, Make the most of your energy, StruxureWare, Square D, PowerLogic, Micrologic, Modicon, and Twido are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. 998-6535_US
The depth of StruxureWare Power Monitoring software makes it simple to match your operational needs, your facility’s portfolio, and your budget. The software is compatible with a host of devices, and new device drivers are added continuously.