SUBMITTAL DATA power vented gas-fired unit heaters model HD

Report 2 Downloads 44 Views
6-460.8 April, 2007

SUBMITTAL DATA power vented gas-fired unit heaters model HD

Certified for Residential and Commercial Use

Dimensions (inches)

Performance HD30

Models

HD45

HD60

HD75

Models

HD100 HD125

HD30 HD45 HD60 HD75 HD100/125

Btu/Hr Input

30,000 45,000 60,000 75,000 100,000 125,000

A

26.8

26.8

26.8

26.8

35.5

Btu/Hr Output

24,000 36,000 48,000 60,000 80,000 100,000

B

12.2

12.2

18.0

18.0

20.5

Entering Airflow (CFM) 505

720

990

1,160

1,490

1,980

C

16.5

16.5

16.5

16.5

22.0

523

749

653

769

565

747

D

14.9

14.9

14.9

14.9

22.5



44

46

45

48

50

47

E

10.1

10.1

15.9

15.9

18.4

Mounting Height (Max ft.)

10

10

12

14

12

16

F

7.5

7.5

10.7

10.7

14.0



25

27

36

38

42

56

G

18.5

18.5

18.5

18.5

24.0

1/15

1/12

1/12

1/12

1/8

H

7.6

7.6

7.8

7.8

8.4

1,550

1,625

1,625

1,050

1,550

Gas Connection

1/2

1/2

1/2

1/2

1/2

S.P.

P.S.C.

I

34.5

34.5

34.5

34.5

43.0

Outlet Velocity Air Temp. Rise (°F) Heat Throw (ft.)

Horsepower 1/15 1,550 RPM

Motor Data

Type

S.P.

S.P.

Amps Unit Total Amps

2.4

2.4

1.2

1.2

2.7

2.2

J



22

22

25

25

31.0

3.7

3.7

2.5

2.5

4.7

4.2

Fan Diameter



10

10

14

14

18.0

3

3

3

4

4

Approx. Shipping Weight (lbs.)



55

60

80

85

125

Vent Connector Size (in.)

3

P.S.C. P.S.C.

Mounting

Clearances

25.10 26.20

23.10

21.10

19.10

9.10

7.10

5.10

3.10

.00 1.10

HD30-75

17.10

1” - angle, mounting brackets are slotted to accommodate joists on 16” or 24” centerlines.

Unit Side

Clearance To   Combustible Materials

Recommended Service Clearance



Top and Bottom

1"

1"



Access Side

18"

18"



Non-Access Side

1"

1"



Rear

18"

18"



Vent Connector

4"

4"

33.50 35.00

31.50

29.50

27.50

25.50

23.50

21.50

13.50

11.50

9.50

7.50

5.50

3.50

.00 1.50

HD100/125

Control Options

Control Description

Control Code No.

Service Voltage

Thermostat Voltage

Type of Gas

Model Size

11

115V

24V

natural

30-125

Gas is lit with a direct spark igniter on call for heat.

21

115V

24V

propane

30-125

Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark igniter on call for heat. ➂

12

115V

24V

natural

75-125

22

115V

24V

propane

75-125

Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a single-stage combination gas control with ignition control.

SUBMITTAL DATA power vented blower gas-fired unit heaters model HDB

Certified for Residential and Commercial Use

MOUNTING HOLES TYP 3/8 X 1" LONG

G

ADJUSTABLE LOUVERS

MOUNTING BRACKETS

A POWER VENTER VENT PIPE CONNECTION

ELECTRICAL CONNECTIONS

1.00

GAS CONNECTION ACCESS PANEL

E OPENING

B F

C J I ACCESS VIEW

REAR VIEW

100,000

100,000

Air Flow CFM Range

635-1100 795-1390 1060-1850 1240-2050

Horsepower RPM

Motor Data

3

1/4

1/3

1/2

1/2

Max 1,100

Max 1,100

Max 1,100

Max 1,100

P.S.C.

P.S.C.

P.S.C.



5.4

7.1

9.5

9.5



6.4

8.1

11.5

11.5

3

3

4

4

Vent Connector Size (in.)

C D 33.50 35.00

3

B

31.50

29.50

27.50

3

25.50

45-75

23.50

40-70

3

P.S.C.

Type

Amps Unit Total Amps

0.8

21.50

13.50



11.50

9.50

Motor Speeds

7.50

5.50

3.50

.00 1.50

Air Temp. Rise (°F)

0.8

HDB 60 HDB 75 HDB100/125

A

Static Pressure (max)

0.7 HD100/125 40-70 40-70

Models

125,000

80,000

0.7

Dimensions (inches)

25.10 26.20

23.10

60,000

HDB125

21.10

48,000

HDB100 19.10

9.10

5.10

3.10

.00 1.10

Btu/Hr Output

7.10

HDB60

Btu/Hr Input

HDB75 HD30-75 60,000 75,000

17.10

Performance Models

H

D OPENING

E F G H Gas Connection I J Blower Approx.Shipping Weight (lbs.)



26.8 18.0 16.5 14.9 15.9 10.7 18.5 7.8 1/2 35.5 32.5 9 - 7 92

26.8 18.0 16.5 14.9 15.9 10.7 18.5 7.8 1/2 35.5 32.5 9 - 7 97

35.5 20.5 22.0 22.5 18.4 14.0 24.0 8.4 1/2 44.5 41.5 10 - 10 151

Mounting 1” - angle, mounting brackets are slotted to accommodate joists on 16” or 24” centerlines.

Clearances

25.10 26.20

23.10

21.10

19.10

9.10

7.10

5.10

3.10

.00 1.10

HD30-75

17.10

Unit Side

33.50 35.00

31.50

29.50

27.50

25.50

23.50

21.50

13.50

11.50

9.50

7.50

5.50

3.50

.00 1.50

HD100/125

Clearance To   Combustible Materials

Recommended Service Clearance



Top and Bottom

1"

1"



Access Side

1"

18"



Non-Access Side

1"

1"



Rear

18"

18"



Vent Connector

4"

4"

Control Options

Control Description

Control Code No.

Service Voltage

Thermostat Voltage

Type of Gas

Model Size

11

115V

24V

natural

30-125

Gas is lit with a direct spark igniter on call for heat.

21

115V

24V

propane

30-125

Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark igniter on call for heat. ➂

12

115V

24V

natural

75-125

22

115V

24V

propane

75-125

Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a single-stage combination gas control with ignition control.

2

6-460.8

SUBMITTAL DATA separated combustion gas-fired unit heaters model HDS

Certified for Residential and Commercial Use

Dimensions (inches) 26.8

35.5

12.2

12.2

18.0

18.0

20.5

9.10

25

Horsepower 1/15 1,550 RPM

Motor Data

1,160

1,490

1,980

C

16.5

16.5

16.5

16.5

22.0

769

565

747

D

14.9

14.9

14.9

14.9

22.5

47

10.1

10.1

15.9

15.9

18.4

16

F

7.25

7.25

10.75 10.75

14.0 24.0

38

42

56

G

18.5

18.5

18.5

1/12

1/12

1/8

H

7.6

7.6

7.835 7.835

1,550

1,625

1,625

1,050

1,550

Gas Connection

1/2

1/2

1/2

1/2

34.5

34.5

34.5

43.0

22

25

25

31.0

48 14

50 12

31.50

36 1/12

12

29.50

27 1/15

45

10

27.50

E

46

25.50

10

990

749 653 HD100/125

HDS30 HDS45 HDS60 HDS75 HDS100/125

33.50 35.00



Heat Throw (ft.)

44

13.50



Mounting Height (Max ft.)

11.50

Air Temp. Rise (°F)

9.50

7.50

5.50

3.50

.00 1.50

720

523

Outlet Velocity

23.50

Entering Airflow (CFM) 505

25.10 26.20

26.8

B

23.10

26.8

24,000 36,000 48,000 60,000 80,000 100,000

21.10

26.8

19.10

A

17.10

Models

30,000 45,000 60,000 75,000 100,000 125,000

21.50

Btu/Hr Output

HD30-75HDS60 HDS75 HDS100 HDS125 HDS30 HDS45 7.10

Btu/Hr Input

5.10

.00 1.10

Models

3.10

Performance

18.5

8.4 1/2

Type

S.P.

S.P.

S.P.

P.S.C.

I

34.5

Amps Unit Total Amps

2.4

2.4

1.2

1.2

2.7

2.2

J



3.7

3.7

2.5

2.5

4.7

4.2

K

2.74

2.74

3.15

3.15

3.87

3

4

4

4

4

L

3.19

3.19

5.55

5.55

10.73

Vent Connector Size (in.)

3

P.S.C. P.S.C.

Fan Diameter

Mounting 1” - angle, mounting brackets are slotted to accommodate joists on 16” or 24” centerlines.



10

10

14

14

18.0

Approx. Shipping Weight (lbs.)

55

60

80

85

125

Clearances

25.10 26.20

23.10

21.10

19.10

9.10

7.10

5.10

3.10

.00 1.10

17.10

Unit Side HD30-75

33.50 35.00

31.50

29.50

27.50

25.50

23.50

21.50

13.50

11.50

9.50

7.50

5.50

3.50

HD100/125 .00 1.50

22

Clearance To   Combustible Materials

Recommended Service Clearance



Top and Bottom

1"

1"



Access Side

1"

18"



Non-Access Side

1"

1"



Rear

18"

18"



Vent Connector

4"

4"

Control Options

Control Description

Control Code No.

Service Voltage

Thermostat Voltage

Type of Gas

Model Size

11

115V

24V

natural

30-125

Gas is lit with a direct spark igniter on call for heat.

21

115V

24V

propane

30-125

Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark igniter on call for heat. ➂

12

115V

24V

natural

75-125

22

115V

24V

propane

75-125

Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a single-stage combination gas control with ignition control.



6-460.8

3

SUBMITTAL DATA separated combustion blower gas-fired  unit heaters — model HDC

Certified for Residential and Commercial Use

MOUNTING HOLES TYP 3/8 X 1" LONG

G SIGHT GLASS

MOUNTING BRACKETS

A POWER VENTER VENT PIPE CONNECTION

ADJUSTABLE LOUVERS

GAS CONNECTION

1.00

TERMINAL STRIP/ GROMMET ACCESS PANEL

B

E OPENING

F L K ELECTRICAL CONNECTION H

C J

D OPENING

I

REAR VIEW

ACCESS VIEW

100,000

Air Flow CFM Range

635-1100 795-1390 1060-1850 1240-2050

Horsepower RPM

Motor Data

3

1/4

1/3

1/2

1/2

Max 1,100

Max 1,100

Max 1,100

Max 1,100

P.S.C.

P.S.C.

P.S.C.



5.4

7.1

9.5

9.5



6.4

8.1

11.5

11.5

4

4

4

4

Vent Connector Size (in.)

C D 33.50 35.00

3

B

31.50

29.50

27.50

3

25.50

45-75

23.50

40-70

3

P.S.C.

Type

Amps Unit Total Amps

0.8

21.50

13.50



11.50

9.50

Motor Speeds

7.50

5.50

3.50

.00 1.50

Air Temp. Rise (°F)

0.8

HDC 60 HDC 75 HDC100/125

A

100,000

Static Pressure (max)

0.7 HD100/125 40-70 40-70

Models

125,000

80,000

0.7

Dimensions (inches)

25.10 26.20

23.10

60,000

HDC125

21.10

48,000

HDC100 19.10

9.10

5.10

Btu/Hr Output

3.10

.00 1.10

Btu/Hr Input

HDC75 HD30-75 60,000 75,000 7.10

HDC60

Models

17.10

Performance

E F G H Gas Connection I J K L Blower

Mounting

Approx.Shipping Weight (lbs.)

1” - angle, mounting brackets are slotted to accommodate joists on 16” or 24” centerlines.

25.10 26.20

23.10

21.10

19.10

17.10

9.10

7.10

5.10

3.10

.00 1.10

33.50 35.00

31.50

29.50

27.50

25.50

23.50

21.50

13.50

11.50

9.50

7.50

5.50

3.50

.00 1.50

HD100/125

26.8 18.0 16.5 14.9 15.9 10.8 18.5 7.8 1/2 35.5 32.5 3.15 5.55 9 - 7 92

26.8 18.0 16.5 14.9 15.9 10.8 18.5 7.8 1/2 35.5 32.5 3.15 5.55 9 - 7 97

35.5 20.5 22.0 22.5 18.4 14.0 24.0 8.4 1/2 44.5 41.5 3.87 10.73 10 - 10 125

Clearances Unit Side

HD30-75



Clearance To   Combustible Materials

Recommended Service Clearance



Top and Bottom

1"

1"



Access Side

1"

18"



Non-Access Side

1"

1"



Rear

18"

18"



Vent Connector

4"

4"

Control Options

Control Description

Control Code No.

Service Voltage

Thermostat Voltage

Type of Gas

Model Size

11

115V

24V

natural

30-125

Gas is lit with a direct spark igniter on call for heat.

21

115V

24V

propane

30-125

Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark igniter on call for heat. ➂

12

115V

24V

natural

75-125

22

115V

24V

propane

75-125

Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry - Utilizes a single-stage combination gas control with ignition control.

Commercial Products Group • Modine Manufacturing Company • 1500 DeKoven Avenue • Racine, Wisconsin 53403-2552 Tel: 262.636.1200 • Fax: 800.204.6011 • www.modine.com © 2007 Modine Manufacturing Company

Litho in USA