SUBMITTAL PACKAGE RETURN 1038-03 - Hyatt Regency Public Space Renovation To: Marcus Esmay ARCHITECTURAL WOODWORK OF MONTANA 106 HWY 2 EAST COLUMBIA FALLS, MT 59912
From: Shane McKinley Hathaway Dinwiddie Construction Co. 275 Battery Street Suite 300 San Francisco, CA 94111-3330
We are transmitting the following Submittal Package Number: “ 27”, Revision: “0” Description: “Restrooms Millwork Shop Drawings” for your review. This package is intended to be compliant with contract Specification Number: “064000”. Please review and respond to Shane McKinley, should you have any questions, or need additional information regarding any of the items. Additional Notes: Pkg #
Item #
27
1t
27
2t
27
3t
27
4t
27
5t
Sincerely,
Rev
Spec
Description PACIFIC CONCOURSE RESTROOMS STREET LEVEL RESTROOMS BAY LEVEL SEACLIFF RESTROOMS (B) - DETAIL 2 ID05.02 BAY LEVEL BAYVIEW RESTROOMS (A) - DETAIL 1 ID05.02 ATRIUM LEVEL RESTROOMS
1038-03 - Hyatt Regency Public Space Renovation To: Jeff Espiritu Looney & Associates 212 Superior Street, Suite 500 Chicago, IL 60654
27
From: Shane McKinley Hathaway Dinwiddie Construction Co. 275 Battery Street Suite 300 San Francisco, CA 94111-3330
We are transmitting the following Submittal Package Number: 27, Revision: 0 Description: Restrooms Millwork Shop Drawings for your review, intended to be compliant with contract Specification Number: 064000. Please review and respond by: 5/22/2015. Additional Notes: Pkg #
Item #
27
1t
27
2t
27
3t
27
4t
27
5t
Rev
Spec
Description PACIFIC CONCOURSE RESTROOMS STREET LEVEL RESTROOMS BAY LEVEL SEACLIFF RESTROOMS (B) DETAIL 2 ID05.02 BAY LEVEL BAYVIEW RESTROOMS (A) DETAIL 1 ID05.02 ATRIUM LEVEL RESTROOMS
Architect Stamp:
Revise and resubmit per Looney's and Axis' comments. C. Sum / AXIS 05/22/15
Details
Status
Drawings dated 5/14/15.
Submitted
Drawings dated 5/14/15.
Submitted
Drawings dated 5/14/15.
Submitted
Drawings dated 5/14/15.
Submitted
Drawings dated 5/14/15.
Submitted
HDCCO JOB #: 1038-03 SUBMITTAL #: 27 DATE: 05/18/2015 Reviewed by: Shane McKinley This submittal has been reviewed for general conformance with the Plans and Specifications. Quantities are the responsibility of the subcontractor and his agents.
Please note the new location of the accessible urinals because the elevations do not show this. The existing accessible urinals are consistently located at the end of the row next to a perpendicular wall. Unfortunately, these urinals are typically located less than 15" from the wall which does not comply with current code. Axis' coordination of the new toilet room layouts found it was less invasive to limit demolition to 2 fixtures and creating the accessible stall through the location of the partitions rather than shifting all the fixtures along the wall. However, the relocation of the accessible urinal means some plumbing work in the wall to mount the new fixtures at the required heights. Please refer to the A8.00 series drawings and keynote 22.3. -C. Sum / AXIS
15" CODE MIN. TYP.
60" CODE MIN.
60" CODE MIN.
36" CODE MIN.
15" CODE MIN. TYP. 60" CODE MIN.
60" CODE MIN.
36" CODE MIN.
36" CODE MIN. 4" MIN.
30" CODE MIN. 15" MIN. 15" MIN.
(N) ACCESSIBLE URINAL
17 ' - 19" PER CODE
CONTRACTOR TO CONFIRM DOOR TO ACCESSIBLE STALL PROVIDES 32" CLEARANCE W/ HARDWARE WHEN OPEN
(E) ACCESSIBLE URINAL STALL
CONTRACTOR - PLEASE NOTE LOCATION OF (N) ACCESSIBLE URINAL STALL
MOUNT AT 48" AFF AT ALL ACCESSIBLE STALLS
OK
15" CODE MIN. TYP.
60" CODE MIN.
EQ.
EQ.
15" CODE MIN. TYP.
36" CODE MIN.
36" CODE MIN.
15" CODE MIN. TYP.
30" CODE MIN. 15" MIN. 15" MIN.
(N) ACCESSIBLE URINAL
WHY IS THIS PARTITION SHORTER?
60" CODE MIN.
CONTRACTOR TO CONFIRM DOOR TO ACCESSIBLE STALL PROVIDES 32" CLEARANCE W/ HARDWARE WHEN OPEN
CONTRACTOR TO CONFIRM DOOR TO ACCESSIBLE STALL PROVIDES 32" CLEARANCE W/ HARDWARE WHEN OPEN