Super-Fast Installation! Super-Fast Installation! Very

Report 0 Downloads 117 Views
Conduit & Fittings — T&B® Cord & Cable Fittings

MC and AC Cable Fittings Tite-Bite Connectors ®

Application • To connect and effectively bond metalclad cables, armored cable or flexible metal conduit to a box or an enclosure

Locknut

Saddle

Features • Provided with an angled saddle designed to:

3110 Series

• Insulated throat protects conductors during and after installation and reduces wire pull effort

Body Insulated Throat

Box or Enclosure Wall

• Heat-curled insulator in throat: • Locknuts designed to provide effective bond between connector and box or enclosure, will not vibrate loose • Designed with fewer installing screws — reduces installation time and labor cost

Standard Material/Finish Body . . . . . . . . . . . . . . . Steel or Malleable Iron/ Electro Zinc Plated & Chromate Coated Saddle. . . . . . . . . . . . . Steel/Electro Zinc Plated & Chromate Coated Screws . . . . . . . . . . . Steel/Electro Zinc Plated & Chromate Coated

• Armor stop with viewing window • Rugged all-steel or malleable iron construction

Insulator . . . . . . . . . . . Thermoplastic/As Molded

• Suitable as a grounding means per NEC® Article 348 for flexible metal conduit, NEC® Article 320 for armored cable and NEC® Article 330 for metalclad cable

UL 514B

UL

(UL File No. 23018)

• Suitable for hazardous location use per Class 1 Division 2 NEC 501.10 (b)(2)

CSA

(LR-2884, LR-4484)

3110 Series Straight Connectors 3130 Series 90° Connectors

Super-Fast Installation! Up to 2X faster than standard connectors!

Listings/Compliances

Range

E-154

Typical Installation

CSA C22.2 No. 18 NEMA FB1

Hub Size

Conduit Size

3 ⁄2" to 4" NPS ⁄8" to 4" 1 3 ⁄2" to 4" NPS ⁄8" to 4" (All hubs provided with straight pipe threads NPS) 1

United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354

Cable Opening

Very High Cable Pull-Out Resistance!

Now UL Listed for New Interlocked Armor Ground Type Metal Clad Cable (MCI-A)!

.470" to 4.560" .470" to 4.560"

Technical Services Tel: 888.862.3289

www.tnb.com

MC and AC Cable Fittings

Squeeze Connectors — Straight B

C

A

Cat. No.

Ins. Cat. No.

252*** 253-TB**†† 254-TB 255 256 257*** 258*** 259*** 249*** 277*** 278-TB***†† 281-TB***††

— 253-I-TB**†† 254-I-TB 255-I 256-I 257-I*** 258-I*** 259-I*** 249-I*** 277-I*** 278-I-TB***†† 281-I-TB***††

CABLE Opening (in.) max.

min.

Trade Size

.531 .585 .938 1.094 1.375 1.656 1.875 2.500 3.062 3.563 4.370 4.600

.437 .455 .812 .938 1.250 1.500 1.688 2.313 2.812 3.312 3.200 3.500

⁄16" 3 ⁄8" 1 ⁄2" 3 ⁄4" 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4" 5

Dimensions (in.)

K.O. Size

A

B

C

⁄8" 1 ⁄2" 1 ⁄2" 3 ⁄4" 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4"

⁄16 31 ⁄32 17⁄32 11⁄4 119⁄32 17⁄8 21⁄4 231⁄32 35⁄16 313⁄16 65⁄8 71⁄4

⁄32 113⁄64 13⁄8 117⁄32 15⁄8 123⁄32 17⁄16 25⁄8 211⁄16 27⁄8 51⁄4 53⁄4

⁄32 ⁄8 13 ⁄32 7 ⁄16 1 ⁄2 17 ⁄32 9 ⁄16 11 ⁄16 3 ⁄4 3 ⁄4 15⁄16 15⁄8

3



13

25

11

5

• Malleable iron or steel construction ** UL Listed for armored cable only. Fitting material steel. *** UL Listed for flexible metal conduit only. † Approximate dimension with screw at minimum height. †† cULus Certified

• Catalog Nos. 252, 253-TB, 254-TB and 255 are steel • Add “I” suffix for insulated throat

.485"–.660" cable opening range for 253-I-TB. ­UL File No. E 23018 CSA File No. 2884

Only two screws to tighten! Squeeze Connectors — 90° Angle

Cat. No. C 266-TB 272** 268-TB B 279 270 273-TB A 274*** 275*** 276*** 282-TB***†† †† • Cap lifts off simply by loosening screws partway 283-TB*** †† 284-TB*** • 3⁄8" and 1⁄2" sizes made of steel 285-TB***††

• 3⁄4" and larger sizes made of malleable iron

Ins. Cat. No. 266-I-TB 272-I** 268-I-TB 279-I 270-I 273-I-TB 274-I*** 275-I*** 276-I*** 282-I-TB***†† 283-I-TB***†† 284-I-TB***†† 285-I-TB***††

CABLE Opening (in.) min.

Trade Size

K.O. Size

A†

B

C

.656 .812 .937 1.000 1.125 1.406 1.656 1.875 2.500 3.100 3.640 4.220 4.600

.406 .688 .813 .875 1.000 1.187 1.375 1.625 2.125 2.520 3.100 3.700 4.100

⁄8" 3 ⁄8" 1 ⁄2" 3 ⁄4" 3 ⁄4" 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4"

⁄2" 1 ⁄2" 1 ⁄2" 3 ⁄4" 3 ⁄4" 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4"

11⁄2 19⁄16 111⁄16 113⁄16 17⁄8 23⁄8 3 33⁄8 41⁄2 45⁄16 51⁄16 613⁄16 71⁄4

113⁄32 17⁄8 113⁄16 21⁄16 13⁄4 27⁄32 3 35⁄16 313⁄16 517⁄16 69⁄16 85⁄16 87⁄8

17⁄16 — 17⁄8 113⁄16 113⁄16 27⁄16 3 4 47⁄8 79⁄16 815⁄16 111⁄4 123⁄8

** UL Listed for armored cable only. *** UL Listed for flexible metal conduit only. † Approximate dimension with screw at minimum height.

• Add “I” suffix for insulated throat

Dimensions (in.)

max.

3

1

Conduit & Fittings — T&B® Cord & Cable Fittings

Fits every size of armored cable, metal-clad cable and flexible metal conduit!

†† cULus Certified UL File No. E23018 CSA File No. 2884

Fast and easy installation — simply loosen screws partway to lift off cap! Squeeze Connectors — 45° Angle C

B A

• ⁄8" and ⁄2" sizes made of steel 3

1

• 3⁄4" size made of malleable iron • Add “I” suffix for insulated throat

www.tnb.com

Cat. No.

Ins. Cat. No.

265 267 269

265-I 267-I 269-I

UL File No. E-23018 CSA File No. 2884

United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354

CABLE Opening (in.) max.

min.

.656 .937 1.125

.406 .813 1.000

Dimensions (in.)

Trade Size

K.O. Size

A†

⁄8" 1 ⁄2" 3 ⁄4"

⁄2" 1 ⁄2" 3 ⁄4"

117⁄32 123⁄32 2

3

1

B

C

⁄32 1 ⁄2 17 ⁄32

11⁄8 11⁄4 19⁄16

15

UL Listed for armored cable and flexible metal conduit. Approximate dimension with screw at minimum height.



Technical Services Tel: 888.862.3289

E-157