ACECLAMP® JR Technical Datasheet Pub 100602-1td V1.0 June 2010
ACECLAMP® JR Primary Block - ¼”.............................................................................. 1 ACECLAMP® JR Primary Block - ⅜”...............................................................................2 ACECLAMP® JR Assembly .............................................................................................2 ACECLAMP® JR - Shown with Top Mounting Hardware . ............................................3
ACECLAMP® JR - ¼” Catalog No. 004030M
• • • • •
Ace Clamp Primary Block-¼” Material: Mill Finish Extruded Aluminum Alloy 6061-T6 .92 Ultimate Tensile: 45 ksi (310 MPa) 1.23 .97 Yield: 40 ksi (275 MPa) Ace Clamp Primary Block-¼” Weight: .34 .60 0.25 lbs 1.00 (113 g) Resistance factors and safety factors are determined according to Part 1 Section 9 of the 2005 Aluminum Design Manual 1.88
2X R.63
2.60
1.94 .06
.47
.92
1.23
1.00
.60
1/4-20 UNC - 2B 1.88
Y
Dimensions specified in inches unless noted X
1
Bright Thinking in Solar
.41
R
® Seamed Metal Roof Mounting Solution
Technical Datasheets
ACECLAMP® JR - ⅜” Catalog No. 004031M
A HILTI GROUP COMPANY
.92 1.23 Ace Clamp Primary Block-⅜” Material: .97 Mill Finish Extruded Aluminum Alloy 6061-T6 Ultimate Tensile: 45 ksi (310 MPa) .34 .60 1.00ksi (275 MPa) Yield: 40 Ace Clamp Primary Block-⅜” Weight: 0.25 lbs (113 g) Resistance factors and safety factors are determined 1.88 9 of the 2005 Aluminum according to Part 1 Section Design Manual
• • • • •
2X R.63
2.60
1.94 .06
.47
.92
1.23
1.00
.60
3/8-16 UNC - 2B 1.88
Y
Dimensions specified in inches unless noted X
ACECLAMP® JR Assembly Applied Load Direction
Average Ultimate (lbs)
Design Factor Φ
Design Load (lbs)
Safety Factor FS
Allowable Load (lbs)
Lateral Parallel to Seam (X)
123
0.35
42.7
4.36
28
Lateral Perpendicular to Seam (Y)
1071
0.41
441.5
3.67
292
Tension (+Z)
336.5
0.51
172.5
2.95
114
Compression (-Z)
1374
0.39
542.7
3.88
354
Allowable and Design Loads are valid when ACECLAMP® JR is assembled on a 24-ga standing seam metal roof panel, with a torque value of 175 in-lbs or 14.58 ft-lbs. Z
Y X
Dimensions specified in inches unless noted
2
Bright Thinking in Solar
.41
R
® Seamed Metal Roof Mounting Solution
Technical Datasheets
A HILTI GROUP COMPANY
ACECLAMP® JR - SHOWN WITH TOP MOUNTING HARDWARE
END CLAMP
MID CLAMP
Note: Top mounting hardware purchased separately. Please refer to product catalog for additional details. Top mounting components must be assembled with the ACECLAMP® JR according to authorized Unirac documents.