2A
Position switches FD series
Selection diagram
01
08
10
11
18
31
51
52
19
02
04
Ø 8 mm Ø 12,7 mm stainless steel stainless steel sphere sphere
external rubber gasket
57
35
fibber glass rod
56
safety adjustable lever adjustable lever
05
41
42
bistable
bistable
ACTUATORS
CONTACT BLOCKS
5
6
7
1NO+1NC snap action
1NO+1NC slow action
1NO+1NC slow action overlapped
15
16
18
2NO 2NC 1NO+1NC slow action slow action slow action shifted independent closer
9
2NC slow action
20
1NO+2NC slow action
10
2NO slow action
21
3NC slow action
11
2NC snap action
22
2NO+1NC slow action
12
2NO snap action
2
2x(1NO-1NC) snap action
13
2NC slow action shifted and spaced
14
2NC slow action shifted
E1
1NO-1NC electronic PNP
CONDUIT ENTRY
Threaded conduit entry M2
PG 13,5 (standard) M20x1,5
With assembled cable gland K21 K25
for Ø 6 to Ø 12 mm cables range for Ø 3 to Ø 7 mm cables range
With M12 metal connector assembled and wired K40 K50
8 poles from bottom 5 poles from bottom
product option accessory sold separately
2/3
General Catalog 2013-2014
2A
15
16
20
21
25
34
stainless steel stainless steel roller lever roller lever
32
33
stainless steel round rod
square rod
36
53
fiber glass rod porcelain roller
external rubber gasket
76
38
rope switches for signalling
without actuator
58
40
without actuator
bistable without actuator
LOOSE ACTUATORS See page 2/11
Code structure
Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article
options
FD 502-1GM2K50 Housing FD
Preinstalled cable gland or connectors
metal housing, one conduit entry
no cable gland or connector (standard) K21
Contact blocks 5
1NO+1NC, snap action
6
1NO+1NC, slow action
7
1NO+1NC, slow action overlapped
...
........................
... K50 ...
01
short plunger roller lever
05
offset roller lever
...
........................
Suffix
1 2
with Ø 35 mm polymer roller (see special loose actuators on page 2/12)
3
with Ø 50 mm rubber roller (see special loose actuators on page 2/12)
4
with Ø 50 mm overhanging rubber roller (see special loose actuators on page 2/12)
General Catalog 2013-2014
5 poles M12 assembled metal connector (see conduit entry page 2/3) ........................
Threaded conduit entry PG 13,5 (standard) M2 M20x1,5
Contacts type
no suffix (standard) with Ø 20 mm stainless steel roller for actuators 02, 05, 31, 35, 51, 52, 56, 57, 41, 42
........................
For the complete list of all combinations, please contact our technical office.
Actuators 02
assembled cable gland (see conduit entry page 2/3)
silver contacts (standard) G
silver contacts gold plated 1 µm (contact block 2 excluded)
2/4
2A
Position switches FD series Technical data Housing Metal housing, coated with baked epoxy powder One threaded conduit entry Protection degree: IP67 according to EN 60529 with cable gland having equal or higher protection degree General data Ambient temperature:
from -25°C to +80°C
Version for operation in ambient temperature from -40°C to +80° C on request
Max actuation frequency: Mechanical endurance: Assembling position: Driving torque for installation:
3600 operations cycles1/hour 20 million operations cycles1 any see pages 7/1-7/12
(1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN 60947-5-1 standard.
Main data Metal housing, one conduit entry Protection degree IP67
Cross section of the conductors (flexible copper wire) Contact blocks 20, 21, 22, 33, 34: min. 1 x 0,34 mm2 max. 2 x 1,5 mm2 Contact blocks 5, 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 18: min. 1 x 0,5 mm2 max. 2 x 2,5 mm2 Contact block 2: min. 1 x 0,5 mm2 max. 2 x 1,5 mm2
(1 x AWG 22) (2 x AWG 16) (1 x AWG 20) (2 x AWG 14) (1 x AWG 20) (2 x AWG 16)
17 contact blocks available 28 actuators available M12 assembled connector versions Silver contacts gold plated versions
Markings and quality marks:
Approval IMQ: Approval UL: Approval CCC: Approval EZU: Approval GOST:
EG605 E131787 2007010305230000 1010151 POCC IT.AB24.B04512
In conformity with standards: IEC 60947-5-1, EN 60947-5-1, EN 60947-1, EN 50041, IEC 60204-1, EN 60204-1, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 60529, EN 60529, NFC 63-140, VDE 0660-200, VDE 0113. Approvals: IEC 60947-5-1, UL 508, GB14048.5-2001.
In conformity with requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and Electromagnetic Compatibility 2004/108/EC. Positive contact opening in conformity with standards: IEC 60947-5-1, EN 60947-5-1, VDE 0660-206.
Installation for safety applications: Use only switches marked with the symbol . The safety circuit must always be connected with the NC contacts (normally closed contacts: 11-12, 21-22 or 31-32) as stated in the standard EN 60947-5-1, encl. K, par. 2. The switch must be actuated with at least up to the positive opening travel shown in the travels diagrams on page 7/4. The switch must be actuated at least with the positive opening force, shown in brackets, underneath each article, near the value of the min. force. If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page 7/1 to page 7/12.
without connector
Thermal current (Ith): 10 A Rated insulation voltage (Ui): 500 Vac 600 Vdc 400Vac 500Vdc (contact blocks 2, 11, 12, 20, 21, 22, 33, 34) Rated impulse withstand voltage (Uimp): 6 kV 4 kV (contact blocks 20, 21, 22, 33, 34) Conditional shot circuit current: 1000 A according to EN 60947-5-1 Protection against short circuits: fuse 10 A 500 V type aM Pollution degree: 3
Alternate current: AC15 (50...60 Hz) Ue (V) 250 400 500 Ie (A) 6 4 1 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 6 1,1 0,4
with 5 poles M12 connector
Utilization categories
Thermal current (Ith): Rated insulation voltage (Ui): Protection against short circuits: Pollution degree:
4A 250 Vac 300 Vdc fuse 4 A 500 V type gG 3
Alternate current: AC15 (50...60 Hz) Ue (V) 24 120 250 Ie (A) 4 4 4 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 4 1,1 0,4
with 8 poles M12 connector
Electrical data
Thermal current (Ith): Rated insulation voltage (Ui): Protection against short circuits: Pollution degree:
2A 30 Vac 36 Vdc fuse 2 A 500 V type gG 3
Alternate current: AC15 (50...60 Hz) Ue (V) 24 Ie (A) 2 Direct current: DC13 Ue (V) 24 Ie (A) 2
2/5
General Catalog 2013-2014
2A Data type approved by IMQ, CCC and EZU
Data type approved by UL
Rated insulation voltage (Ui): 500 Vac 400 Vac (for contact blocks 2, 11, 12, 20, 21, 22, 33, 34) Thermal current (Ith): 10 A Protection against short circuits: fuse 10 A 500 V type aM Rated impulse withstand voltage (Uimp): 6 kV 4 kV (for contact blocks 20, 21, 22, 33, 34) Protection degree: IP67 MV terminals (screw clamps) Pollution degree 3 Utilization category: AC15 Operation voltage (Ue): 400 Vac (50 Hz) Operation current (Ie): 3 A Forms of the contact element: Za, Zb, Za+Za, Y+Y, X+X, Y+Y+X, Y+Y+Y, Y+X+X Positive opening of contacts on contact block 5, 6, 7, 9, 11, 13, 14, 16, 18, 20, 21, 22, 33, 34
Utilization categories Q300 (69 VA, 125-250 Vdc) A600 (720 VA, 120-600 Vac) Data of the housing type 1, 4X “indoor use only”, 12, 13 For all contact blocks except 2 and 3 use 60 or 75 °C copper (Cu) conductor and wire size No. 12-14 AWG. Terminal tightening torque of 7,1 lb in (0.8 Nm). For contact blocks 2 and 3 use 60 or 75 °C copper (Cu) conductor and wire size No. 14 AWG. Terminal tightening torque of 12 lb in (1.4 Nm). In conformity with standard: UL 508
Please contact our technical service for the list of approved products.
In conformity with standards: EN 60947-1, EN 60947-5-1+ A1:2009, fundamental requirements of the Low Voltage Directive 2006/95/CE. Please contact our technical service for the list of approved products.
Adjustable levers
Overturning levers
Rotating heads
In switches with revolving lever it is possible to adjust the lever with 10° steps for the whole 360° range. The positive movement transmission is always guaranteed 10° thanks to the particular geometrical coupling between the lever and the revolving shaft as prescribed for safety applications by the German standard BG-GSET-15.
It’s possible to fasten the lever on switches on straight or reverse side, maintaining the positive coupling. In this way it is possible to obtain two different work plans of the lever.
In all switches, it is possible to rotate the head in 90° steps.
Working operation of contact block 16 with independent contacts The contact block 16 has two NC contacts, both with positive opening activated independently according to the lever turning direction. Lever turned to left
Contacts diagram 11
12
21
22
Lever not turned
Contacts diagram
Lever turned to right
Contacts diagram
11
12
11
12
21
22
21
22
Unidirectional heads In the switches with revolving lever, it is possible to select the directional operation by removing the four screws of the head and revolving the internal piston (contact block 16 excluded).
General Catalog 2013-2014
2/6
2A
Position switches FD series With stainless steel roller on request
Contacts type:
LA
R L LO L L R R LV LS LS LA L L L R
Max speed Min. force Travel diagrams
53
48 - 60
52
60 5.3x7.3
15
30
1NO+1NC FD 501 1NO+1NC FD 601 1NO+1NC FD 701 2NC FD 901 2NO FD 1001 2NC FD 1101 2NO FD 1201 2NC FD 1301 2NC FD 1401 2NO FD 1501 1NO+1NC FD 1801 1NO+2NC FD 2001 3NC FD 2101 2NO+1NC FD 2201 2x(1NO-1NC) FD 201 1NO-1NC FD E101 page 7/3 - type 4 8 N (25 N ) page 7/4 - group 1
40
16 38
5.3 22
119.5
38
5.3x7.3 40
5.3
30
16
60
5.3
60
38
30
114.5 - 126.5
118.5
16
Contact blocks
5 6 7 9 10 11 12 13 14 15 18 20 21 22 2 E1
7
24
5.3
30
15 30
1NO+1NC FD 502 1NO+1NC FD 602 1NO+1NC FD 702 2NC FD 902 2NO FD 1002 2NC FD 1102 2NO FD 1202 2NC FD 1302 2NC FD 1402 2NO FD 1502 1NO+1NC FD 1802 1NO+2NC FD 2002 3NC FD 2102 2NO+1NC FD 2202 2x(1NO-1NC) FD 202 1NO-1NC FD E102 page 7/3 - type 3 6 N (25 N ) page 7/4 - group 2
38 5.3x7.3
40
15 30
FD 504 FD 604 FD 704 FD 904 FD 1004 FD 1104 FD 1204 FD 1304 FD 1404 FD 1504 FD 1804 FD 2004 FD 2104 FD 2204 FD 204 FD E104
16
30
5.3x7.3
1NO+1NC 1NO+1NC 1NO+1NC 2NC 2NO 2NC 2NO 2NC 2NC 2NO 1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
0,5 m/s 0,17 Nm page 7/4 - group 1
With external rubber gasket
6.5
LI
shifted and spaced = slow action independent = slow action closer = electronic PNP
21
Ø 6x200
6.5
shifted
LV = slow action
6.5
Ø 10
90.5 60
187 max.
20
overlapped
LS = slow action
6.5
7
20
26
R = snap action L = slow action LO = slow action
With stainless steel roller on request
40
15 30
1NO+1NC FD 505 1NO+1NC FD 605 1NO+1NC FD 705 2NC FD 905 2NO FD 1005 2NC FD 1105 2NO FD 1205 2NC FD 1305 2NC FD 1405 2NO FD 1505 1NO+1NC FD 1805 1NO+2NC FD 2005 3NC FD 2105 FD 2205 2NO+1NC 2x(1NO-1NC) FD 205 1NO-1NC FD E105 page 7/3 - type 3 6 N (25 N ) page 7/4 - group 2 With external rubber gasket
4
13
Ø 10
Ø 10
L LO L L R R LV LS LS LA L L L R
Max speed Min. force Travel diagrams
FD 508 1NO+1NC FD 608 1NO+1NC FD 708 2NC FD 908 2NO FD 1008 2NC FD 1108 2NO FD 1208 2NC FD 1308 2NC FD 1408 2NO FD 1508 1NO+1NC FD 1808 1NO+2NC FD 2008 3NC FD 2108 2NO+1NC FD 2208 2x(1NO-1NC) FD 208 1NO-1NC FD E108 page 7/3 - type 4 8 N (25 N ) page 7/4 - group 1 1NO+1NC
38
116.5
37 40
16
30
15 30
FD 510 1NO+1NC FD 610 1NO+1NC FD 710 2NC FD 910 2NO FD 1010 2NC FD 1110 2NO FD 1210 2NC FD 1310 2NC FD 1410 2NO FD 1510 1NO+1NC FD 1810 1NO+2NC FD 2010 3NC FD 2110 2NO+1NC FD 2210 2x(1NO-1NC) FD 210 1NO-1NC FD E110 page 7/3 - type 4 11 N (25 N ) page 7/4 - group 1 1NO+1NC
5.3
16
60
38
40
5.3x7.3 15
30
FD 511 1NO+1NC FD 611 1NO+1NC FD 711 2NC FD 911 2NO FD 1011 2NC FD 1111 2NO FD 1211 2NC FD 1311 2NC FD 1411 2NO FD 1511 1NO+1NC FD 1811 1NO+2NC FD 2011 3NC FD 2111 FD 2211 2NO+1NC 2x(1NO-1NC) FD 211 1NO-1NC FD E111 page 7/3 - type 4 8 N (25 N ) page 7/4 - group 1 1NO+1NC
6.5
30
5.3
5.3x7.3
6.5
15
6.5
6.5
5 6 7 9 10 11 12 13 14 15 18 20 21 22 2 E1
30
5.3x7.3
Contact blocks R
38
30
5.3x7.3 40
16
60
60
38
103.5
5.3
16
103.5
37
29
5.3
95.5 60
30
50
Ø 10
40
15 30
FD 515 1NO+1NC FD 615 1NO+1NC FD 715 2NC FD 915 2NO FD 1015 2NC FD 1115 2NO FD 1215 2NC FD 1315 2NC FD 1415 2NO FD 1515 1NO+1NC FD 1815 1NO+2NC FD 2015 3NC FD 2115 FD 2215 2NO+1NC 2x(1NO-1NC) FD 215 1NO-1NC FD E115 page 7/3 - type 2 11 N (25 N ) page 7/4 - group 1 1NO+1NC
Accessories See page 6/1 All measures in the drawings are in mm
2/7
General Catalog 2013-2014
2A Ø 8 mm stainless steel sphere
With external rubber gasket
Ø 12,7 mm stainless steel sphere
LA
R L LO L L R R LV LS LS LA L L L R
Max speed Min. force Travel diagrams
120 30
1NO+1NC FD 516 1NO+1NC FD 616 1NO+1NC FD 716 2NC FD 916 FD 1016 2NO 2NC FD 1116 2NO FD 1216 2NC FD 1316 2NC FD 1416 FD 1516 2NO 1NO+1NC FD 1816 1NO+2NC FD 2016 3NC FD 2116 FD 2216 2NO+1NC 2x(1NO-1NC) FD 216 1NO-1NC FD E116 page 7/3 - type 2 8 N (25 N ) page 7/4 - group 1
60 40
18.5
5.3
15 30
5.3x7.3
40
15
15
40
30
30
1NO+1NC FD 519 1NO+1NC FD 619 1NO+1NC FD 719 2NC FD 919 FD 1019 2NO 2NC FD 1119 2NO FD 1219 2NC FD 1319 2NC FD 1419 FD 1519 2NO 1NO+1NC FD 1819 1NO+2NC FD 2019 3NC FD 2119 FD 2219 2NO+1NC 2x(1NO-1NC) FD 219 1NO-1NC FD E119 page 7/3 - type 4 8 N (25 N ) page 7/4 - group 1
With external rubber gasket
16 38
5.3x7.3
1NO+1NC FD 518 1NO+1NC FD 618 1NO+1NC FD 718 2NC FD 918 FD 1018 2NO 2NC FD 1118 2NO FD 1218 2NC FD 1318 2NC FD 1418 FD 1518 2NO 1NO+1NC FD 1818 1NO+2NC FD 2018 3NC FD 2118 FD 2218 2NO+1NC 2x(1NO-1NC) FD 218 1NO-1NC FD E118 page 7/3 - type 4 8 N (25 N ) page 7/4 - group 1
With external rubber gasket
30
16 38
5.3x7.3 15
186.5
5.3
30
60
38
5.3x7.3 40
16
60
38
5.3
114.5
30
107.5
16
Contact blocks
5 6 7 9 10 11 12 13 14 15 18 20 21 22 2 E1
48
41
50
5.3
30
6.5
LI
shifted and spaced = slow action independent = slow action closer = electronic PNP
6.5
shifted
LV = slow action
6.5
4
overlapped
LS = slow action
116.5
13
60
R = snap action L = slow action LO = slow action
6.5
55
Contacts type:
FD 520
1NO+1NC
FD 1020
2NO
FD 1820 FD 2020 FD 2120 FD 2220 FD 220 FD E120
1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
1 m/s 0,09 Nm page 7/4 - group 3
Other rollers available. See page 2/12
Ø 3 mm stainless steel round rod
Ø 1.2
5 6 7 9 10 11 12 13 14 15 16 18 20 21 22 2 E1
R
1NO+1NC
FD 525
1NO+1NC
L LO L L
FD 1021
2NO
FD 1025
2NO
R R LV LS LS LI LA L L L R
Max speed Min. force Travel diagrams
FD 1821 FD 2021 FD 2121 FD 2221 FD 221 FD E121
1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
1 m/s 0,08 Nm page 7/4 - group 3
FD 1825 FD 2025 FD 2125 FD 2225 FD 225 FD E125
31 5.3
60
107.5 - 204.5
128.5
30
40
38
1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
1 m/s 0,14 Nm page 7/4 - group 3
40
FD 531 FD 631 FD 731 FD 931 FD 1031 FD 1131 FD 1231 FD 1331 FD 1431 FD 1531 FD 1631 FD 1831 FD 2031 FD 2131 FD 2231 FD 231 FD E131
5.3x7.3 15 30
1NO+1NC 1NO+1NC 1NO+1NC 2NC 2NO 2NC 2NO 2NC 2NC 2NO 2NC 1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
page 7/3 - type 1 0,1 Nm (0,25 Nm ) page 7/4 - group 4
38
30 15
40
6.5
30
5.3
5.3x7.3
15 6.5
5.3x7.3
30 60
38
15
40
16
60
38
31
22
18.5
30
6.5
6.5
FD 521
5.3
16
30 5.3x7.3
Contact blocks
189.5
201.5
18.5 60
5.3
47.5
4.5
41 - 138
7
62
37.5
22
123
135
Ø3x125
56.5
20
87
Ø 7.5
FD 532 FD 632 FD 732 FD 932 FD 1032 FD 1132 FD 1232 FD 1332 FD 1432 FD 1532 FD 1632 FD 1832 FD 2032 FD 2132 FD 2232 FD 232 FD E132
30
1NO+1NC 1NO+1NC 1NO+1NC 2NC 2NO 2NC 2NO 2NC 2NC 2NO 2NC 1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
1,5 m/s 0,1 Nm page 7/4 - group 4
Items with code on the green background are available in stock
General Catalog 2013-2014
2/8
2A
Position switches FD series Other rollers available. See page 2/12
3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
2NO 2NC 1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
1 m/s 0,1 Nm page 7/4 - group 4
Other rollers available. See page 2/12
Other rollers available. See page 2/12
Min. force
55.5 7
20
Travel diagrams
30
30
L LO L L R R LV LS LS
FD 551 FD 651 FD 751 FD 951 FD 1051 FD 1151 FD 1251 FD 1351 FD 1451 FD 1551
1NO+1NC
FD 1851 FD 2051 FD 2151 FD 2251 FD 251 FD E151
1NO+1NC
1NO+1NC 1NO+1NC 2NC 2NO 2NC 2NO 2NC 2NC 2NO
6.5
6.5
5 6 7 9 10 11 12 13 14 15 16 18 20 21 22 2 E1
40
L L L R
Max speed Min. force Travel diagrams
(1)
2NC
6.5
2NO (1)
2NC
(1)
1NO+1NC
(1)
1NO+2NC
(1)
3NC
(1)
2NO+1NC 2x(1NO-1NC) 1NO-1NC
30
FD 552 FD 652 FD 752 FD 952 FD 1052 FD 1152 FD 1252 FD 1352 FD 1452 FD 1552
1NO+1NC
FD 1852 FD 2052 FD 2152 FD 2252 FD 252 FD E152
1NO+1NC
1NO+1NC 1NO+1NC 2NC 2NO
2NC 2NC 2NO
1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
page 7/3 - type 1 0,06 Nm (0,25 Nm ) page 7/4 - group 4
1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
page 7/3 - type 1 0,06 Nm (0,25 Nm ) page 7/4 - group 4
2NC 2NO 2NC 2NO 2NC 2NC 2NO 2NC 1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
Other rollers available. See page 2/12 52.5
43
7
29
30
38
41.5
7
30
38 5.3x7.3
15
40
FD 553-E11V9 FD 653-E11V9 FD 753-E11V9 FD 953-E11V9 FD 1053-E11V9
1NO+1NC
FD 1253-E11V9 FD 1353-E11V9 FD 1453-E11V9 FD 1553-E11V9
2NO
FD 556 FD 656 FD 756 FD 956 FD 1056 FD 1156 FD 1256 FD 1356 FD 1456 FD 1556 FD 1656 FD 1856 FD 2056 FD 2156 FD 2256 FD 256 FD E156
1NO+1NC 1NO+1NC 2NC 2NO
2NC 2NC 2NO
1NO+1NC FD 1853-E11V9 1NO+2NC FD 2053-E11V9 3NC FD 2153-E11V9 2NO+1NC FD 2253-E11V9 2x(1NO-1NC) FD 253-E11 1NO-1NC FD E153-E11V9 0,5 m/s 0,03 Nm (0,25 Nm ) page 7/4 - group 5
15
40
30
2NC 2NO
1NO+1NC
1,5 m/s 0,1 Nm page 7/4 - group 4
Porcelain roller
5.3x7.3 15
31
107.5 - 277.5 41 - 211
60
2NC
LI LA
22
31 (1)
5.3x7.3 15
Contact blocks
2NO
page 7/3 - type 1 0,1 Nm (0,25 Nm ) page 7/4 - group 4
38
60
60
38
40
2NC
71
31
22
5.3
62 128.5
30
(1)
41.5
30.5
16.5
2NC 2NO
Ø9
5.3x7.3
R
56 - 115
2NC
1,5 m/s 0,1 Nm page 7/4 - group 4
Max speed
22 60
2NC
(1)
1NO+1NC
31
R
1NO+2NC
2NO
1NO+1NC
1NO+1NC
20
L
1NO+1NC
2NC
(1)
FD 536 FD 636 FD 736 FD 936 FD 1036 FD 1136 FD 1236 FD 1336 FD 1436 FD 1536 FD 1636 FD 1836 FD 2036 FD 2136 FD 2236 FD 236 FD E136
5.3
L
2NC
2NO
1NO+1NC
30
56 - 115
L
2NO
2NC
1NO+1NC
(1)
122.5 - 181.5
LA
2NC
1NO+1NC
(1)
60
LI
2NC
1NO+1NC
15
40
6.5
LS
2NO
FD 535 FD 635 FD 735 FD 935 FD 1035 FD 1135 FD 1235 FD 1335 FD 1435 FD 1535 FD 1635 FD 1835 FD 2035 FD 2135 FD 2235 FD 235 FD E135
1NO+1NC
57
LS
2NC
30
31
LV
2NO
30
15
5.3
R
2NC
40
22
R
1NO+1NC
15
FD 534 FD 634 FD 734 FD 934 FD 1034 FD 1134 FD 1234 FD 1334 FD 1434 FD 1534 FD 1634 FD 1834 FD 2034 FD 2134 FD 2234 FD 234 FD E134
30 5.3x7.3
60
L
1NO+1NC
38
22
30
1NO+1NC
40
6.5
15
10
5.3x7.3
6.5
L
122.5 - 181.5
5.3x7.3
40
7
38
30
102
LO
22
194.5
5.3x7.3
FD 533 FD 633 FD 733 FD 933 FD 1033 FD 1133 FD 1233 FD 1333 FD 1433 FD 1533 FD 1633 FD 1833 FD 2033 FD 2133 FD 2233 FD 233 FD E133
41.5
49
5.3
168.5
L
38
31
R
5.3
30 60
30
Contact blocks
5 6 7 9 10 11 12 13 14 15 16 18 20 21 22 2 E1
31
128
41 - 138 22
31
38
20
5.3
5.3
LA
Ø 7.3
6.5
LI
47.5
22
LV
4.5
137.5
LS
overlapped = slow action shifted = slow action shifted and spaced = slow action independent = slow action closer = electronic PNP
60
40
6.5
3x3x125
R = snap action L = slow action LO = slow action
107.5 - 204.5
Ø6x200
55
Contacts type:
Fiber glass rod
52.5
20
54
5.3
3x3 mm square rod
30
1NO+1NC 1NO+1NC 1NO+1NC 2NC 2NO 2NC 2NO 2NC 2NC 2NO 2NC 1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
page 7/3 - type 1 0,1 Nm (0,25 Nm ) page 7/4 - group 4
Accessories See page 6/1 (1)
Positive opening only with lever adjusted on the max. See page 2/11.
2/9
General Catalog 2013-2014
2A
5.3x7.3 40
R L LO L L R R LV LS LS LI LA L L L R
Max speed Min. force Travel diagrams
5 6 7 9 10 11 12 13 14 15 16 18 20 21 22 2 E1
FD 557 FD 657 FD 757 FD 957 FD 1057 FD 1157 FD 1257 FD 1357 FD 1457 FD 1557 FD 1657 FD 1857 FD 2057 FD 2157 FD 2257 FD 257 FD E157
30
1NO+1NC 1NO+1NC 1NO+1NC
40
30
5.3
38
60
116.9
32.1
15.3
62 128.5
22
1NO+1NC
Bistable switch with single track lyra lever
38
15
5.3
30
FD 541
31
62 31 128.5 60
5.3x7.3
38
15
5.3 15
Contact blocks
5 6 7 9 10 11 12 13 14 15 16 18 20 21 22 2 E1
22
31
5.3
65 22 131.5
38
16 47.4
40
FD 542
30
1NO+1NC
Bistable switch with double track lyra lever
2NC 2NO 2NC 2NO 2NC 2NC 2NO
15 6.5
LA
30 60
LI
shifted and spaced = slow action independent = slow action closer = electronic PNP
6.5
shifted
LV = slow action
6.5
overlapped
LS = slow action
40.3
20
31.5
Rope switches for signalling
57.7 7
20
7
20
57.7
20
7
60
20
62.5
R = snap action L = slow action LO = slow action
With stainless steel rollers on request
6.5
Contacts type:
With stainless steel rollers on request
5.3x7.3
Other rollers available. See page 2/12
40
30
FD 576 FD 676 FD 776 FD 976 FD 1076 FD 1176 FD 1276 FD 1376 FD 1476 FD 1576
1NO+1NC
FD 1876 FD 2076 FD 2176 FD 2276 FD 276
1NO+1NC
1NO+1NC 1NO+1NC 2NO 2NC 2NO 2NC 2NO 2NO 2NC
2NC 1NO+1NC 1NO+2NC 3NC 2NO+1NC 2x(1NO-1NC) 1NO-1NC
page 7/3 - type 1 0,1 Nm (0,25 Nm ) page 7/4 - group 4
45° 65° 80°90°
0 25°
S
45° 65° 80°90°
0 25°
S
S = mechanical snap point positive opening with 21-22 contact only
S = mechanical snap point positive opening with 21-22 contact only
0,5 m/s with 30° cam 0,21 Nm (0,36 Nm )
0,5 m/s with 30° cam 0,21 Nm (0,36 Nm )
2NO+1NC 3NC 1NO+2NC 2x(1NO-1NC)
0,5 m/s initial 20 N - final 40 N page 7/4 - group 6
R L LO L L R R LV LS LS LI LA L L L R
Max speed Min. force Travel diagrams
Items with code on the green background are available in stock
General Catalog 2013-2014
2/10
2A
Position switches FD series Position switches with revolving lever without actuator
LA
LO L L R R LV LS LS LI LA L L L R
Min. force Travel diagrams
22
31
M5
M5
5.3
22
31
M5
22
L
5.3
40
15 30
38
60 5.3x7.3
1NO+1NC FD 538 1NO+1NC FD 638 1NO+1NC FD 738 2NC FD 938 2NO FD 1038 2NC FD 1138 2NO FD 1238 2NC FD 1338 2NC FD 1438 2NO FD 1538 2NC FD 1638 1NO+1NC FD 1838 1NO+2NC FD 2038 3NC FD 2138 2NO+1NC FD 2238 FD 238 2x(1NO-1NC) 1NO-1NC FD E138 0,1 Nm (0,25 Nm ) page 7/4 - group 4
R
44.6
38
5.3x7.3
Contact blocks
5 6 7 9 10 11 12 13 14 15 16 18 20 21 22 2 E1
30
38
5.3x7.3 15 30
40
FD 558 FD 658 FD 758 FD 958 FD 1058 FD 1158 FD 1258 FD 1358 FD 1458 FD 1558
40
6.5
LI
5.3
30
28
31.5
60
LV
6.5
LS
28
42.5
60
28
overlapped = slow action shifted = slow action shifted and spaced = slow action independent = slow action closer = electronic PNP
6.5
R = snap action L = slow action LO = slow action
IMPORTANT For safety applications: join only switches and actuators marked with symbol . For more information about safety applications see page 7/1.
Compact head
31
Regular head
Contacts type:
15 30
FD 540
1NO+1NC 1NO+1NC
1NO+1NC
Bistable switch
1NO+1NC
45° 65° 80°90°
0
2NC 2NO
25°
2NC
S
S = mechanical snap point positive opening with 21-22 contact only
2NO 2NC 2NC 2NO
1NO+1NC FD 1858 1NO+2NC FD 2058 3NC FD 2158 2NO+1NC FD 2258 FD 258 2x(1NO-1NC) 1NO-1NC FD E158 0,06 Nm (0,25 Nm ) page 7/4 - group 4
0,5 m/s with 30° cam 0,21 Nm (0,36 Nm )
Loose actuators IMPORTANT: These loose actuators can be used with items of series FD, FP, FL, FC only.
55
7
M5
M5
M5
M5
6.5
M5
5
7
40
Ø6x200 10
4.5
34 - 93
5
106
20
4.5
19 - 116
13.5
Adjustable fiber glass rod
1 10
20
3x3x125
Ø 3x125 4.9
Adjustable actuator with polymer roller
Flexible rod actuator
19 - 189
Adjustable square rod 3x3x125 mm
M5
Adjustable round rod Ø 3x125 mm
19 - 116
Polymer roller Ø 20 mm
2.5
VF L32
Single track lyra actuator
Double tracks lyra actuator
VF L33
11.5
VF L34
(3)
Polymer roller Ø 20 mm
VF L35
Polymer roller Ø 20 mm
11.5
7 34 - 93
20
Ø9
11
7
M5
M5
80
20
7
M5
M5
18.7
49
40 42.4 62.4
7
M5
18.7
M5
42.4 62.4
M5
40.2 21.2
40.2 21.2
57
20
24
Polymer roller Ø 20 mm
20
15
(3)
1 10
20
20
1 10 20
7
21.6 7
Adjustable safety actuator with polymer roller
Porcelain roller
2.5 17.4
VF L36
(1) (3)
43
VF L31
(3)
VF L42
VF L51
VF L52
VF L53
(2)
VF L56
(3)
- Only orders for multiple quantities of the packs are accepted. - (1) Actuator VF L35 suits to safety applications only if adjusted to its max length, as you can see in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever VF L56. - (2) The position switch obtained by assembling the switch FD •58 (e.g. FD 558, FD 658) with the actuator VF L53 will not present the same travel diagrams and actuating forces as the position switch FD •53-E11V9 (e.g. FD 553-E11V9, FD 653-E11V9...). - (3) If it is installed with switch FD •58 (e.g. FD 558, FD 658..), the actuator can mechanically interfere with the housing of the switch. The interference could happen or not according to the actuator and the head fixing position. - (4) The actuator cannot be oriented to inside direction because it will mechanically interfere with the switch head. Accessories See page 6/1
2/11
VF L57
93
VF L41
Items with code on the green background are available in stock
General Catalog 2013-2014
2A Special loose actuators IMPORTANT: These loose actuators can be used with items of series FD, FP, FL, FC only.
Ø 20 mm stainless steel rollers 1 10
34 - 93
VF L31-1
VF L35-1
M5
7
M5
VF L51-1
(1) (3)
20
7 M5
49 M5
M5
40
M5
7
11
43
20 7
34 - 93
40
7
7
20
24
20
20
15
13.5
5
1 10
20
20
1 10
VF L52-1
VF L56-1
VF L57-1
(3)
Ø 35 mm polymer rollers 0.8 9.5
7
35
19.5
7
35
VF L52-2
(4)
50.5
M5
M5
M5
VF L51-2
(1) (3)
41.3 - 101.3
56.1
M5
VF L35-2
(4)
10.8
7
35 47.5
M5 M5
VF L31-2
9.5
35
7
47.5
35
7
0.8
24 43.5 - 101
13.5
7
35
0.8 9.5
VF L56-2
VF L57-2
(3)
Ø 40 mm rubber rollers 3
10 22
40
10
VF L31-R5
VF L35-R5
(4)
VF L51-R5
(1) (3)
VF L52-R5
(4)
M5
M5
M5
M5
M5
53
59
40 50
40 M5
50
12
40
10
3
26 10
52.5 - 103.5
16
12 10 50 - 103.8
40
10
40
12
3
VF L56-R5
VF L57-R5
(3)
(4)
Ø 50 mm rubber rollers 3
10
10 22
10
50
10
10
58
58.8 - 108
64
55
VF L31-3
(4)
VF L35-3
(1) (3)
VF L51-3
VF L52-3
(4)
M5
M5
M5
M5
M5
M5
55
58.5 - 108
50
50
10
50
16
12
26
12
50
12
50
3
(4)
VF L56-3
(3)
VF L57-3
(4)
Ø 50 mm overhanging rubber rollers
VF L35-4
General Catalog 2013-2014
(1) (3)
M5
10
M5
10
58.8 - 108
58.5 - 108
50
11.4 - 26.4 20 - 35
50
11.4 - 26.4 20 - 35
VF L56-4
(3)
2/12