typical rtx structure typical rdcsb structure typical rdtx structure typical

Report 20 Downloads 385 Views
TYPICAL RTX STRUCTURE

TYPICAL RDCSB STRUCTURE

12'

10'

2'-6"

2'-6"

6.875"

4'-6"

4'-6"

2'-6"

2'-6"

6" 1'-2"

9"

8.25" 1' 7'

7' 5'-6"

5'-6" 2'-6"

2'-6"

1' 7'

7'

1'

8'

6'

2'

2' *VARIES*

*VARIES*

12'

TYPICAL RDTX STRUCTURE

TYPICAL RDE STRUCTURE

12'

10'

10' 4'-6"

4'-6"

2'-6"

2'-6"

6.875"

4'-6"

2'-6"

4'-6"

6.875"

2'-6"

9"

8.25" 7' 2'-6"

4'-8"

4'-8"

5'-6"

5'-6"

20"

2'-6"

8"

18" 8"

8.25"

7' 12"

6'

2'

6'

*VARIES*

2'

*VARIES*

20'

RDE

PRJ.# - DWG.#:

KINGDOM COMMUNITY WIND

27002 -102 ENGIN'D BY:

NOTE: ALL BOLT LENGTHS AND HARDWARE QUANTITIES ARE APPROXIMATE. CONTRACTOR TO VERIFY BEFORE ORDERING.

GREEN MOUNTAIN POWER LOWELL, VERMONT 0

NO.

ISSUED FOR BID

REVISION/ISSUE

5/17/11

DATE

18 Meadow Road P.O. Box 722 Augusta, ME 04332 Phone 207-621-1077

34.5KV OVERHEAD THREE PHASE TRUNK LINE TYPICAL DOUBLE CIRCUIT STRUCTURE DETAILS

NSH DRAWN BY: CJL DATE: 5/16/11

TYPICAL RDEB STRUCTURE

TYPICAL RDE-RISER STRUCTURE 10' 4'-6"

4'-6"

6.875"

1'-2" 8"

3" 18" 7'

8.25"

6'

3"

7'

5"

6'

2'-11"

5"

12"

6'

3"

2'

2'

*VARIES* *VARIES*

TYPICAL RSX STRUCTURE

TYPICAL RDX-RISER STRUCTURE 10' 2'-6"

10' 2'-6"

2'-6"

2'-6"

6.875"

6.875"

4'-8"

4'-8"

4'-8"

1'-4"

4'-8"

1'-4"

8.25"

8.25"

6'

6'

1'

2'

5"

2'-11"

5"

6'

2'

*VARIES*

*VARIES*

PRJ.# - DWG.#:

KINGDOM COMMUNITY WIND

27002 -103-S1 ENGIN'D BY:

NOTE: ALL BOLT LENGTHS AND HARDWARE QUANTITIES ARE APPROXIMATE. CONTRACTOR TO VERIFY BEFORE ORDERING.

GREEN MOUNTAIN POWER LOWELL, VERMONT 0

NO.

ISSUED FOR BID

REVISION/ISSUE

5/17/11

DATE

18 Meadow Road P.O. Box 722 Augusta, ME 04332 Phone 207-621-1077

34.5KV OVERHEAD THREE PHASE TRUNK LINE TYPICAL SINGLE CIRCUIT STRUCTURE DETAILS

NSH DRAWN BY: CJL DATE: 5/16/11

TYPICAL RLD STRUCTURE

TYPICAL RAR STRUCTURE 21'

24'-6"

6"

3'-6"

6'-6"

3'-6"

TYPICAL RDAR STRUCTURE 24'-6"

3'-6"

6'-6"

3'-6"

5'

5'

5'

5'

3'-6"

6'-6"

6'-6"

3'-6"

6"

6"

5.75"

5.75"

5.75"

1'

1'

1'

7.75"

1'

7.75"

1'

7.75"

4'

4'

12'

10'

10'

10'

9'

1'

3'

10'

10'

*VARIES*

*VARIES*

1'

10'

*VARIES*

10'

10'

10'

PRJ.# - DWG.#:

KINGDOM COMMUNITY WIND

27002 -103-S2 ENGIN'D BY:

NOTE: ALL BOLT LENGTHS AND HARDWARE QUANTITIES ARE APPROXIMATE. CONTRACTOR TO VERIFY BEFORE ORDERING.

GREEN MOUNTAIN POWER LOWELL, VERMONT 0 NO.

ISSUED FOR BID REVISION/ISSUE

5/17/11 DATE

18 Meadow Road P.O. Box 722 Augusta, ME 04332 Phone 207-621-1077

34.5KV OVERHEAD THREE PHASE TRUNK LINE TYPICAL SINGLE CIRCUIT STRUCTURE DETAILS

NSH DRAWN BY: CJL DATE: 5/16/11

TYPICAL DOUBLE X-ARM W/ BRACE DETAIL

TYPICAL SINGLE X-ARM W/ BRACE DETAIL

TYPICAL SUSPENSION OFFSET BRACKET DETAIL

TYPICAL DEAD END INSULATOR DETAIL

TYPICAL SINGLE X-ARM DETAIL

2'

TYPICAL NEUTRAL ANGLED DEAD END DETAIL

TYPICAL NEUTRAL INLINE DEAD END DETAIL

TYPICAL NEUTRAL SUSPENSION OFFSET BRACKET DETAIL

TYPICAL NEUTRAL/FIBER SUSPENSION DETAIL

TYPICAL NEUTRAL DEAD END DETAIL

BACKFILL SEE NOTE

SEE NOTE

UNDISTURBED EARTH

SOLID ROCK

5' MIN

12 'M

IN

LOOSE SOIL

TYPICAL DOUBLE GUY ATTACHMENT DETAIL

TYPICAL SINGLE GUY ATTACHMENT DETAIL

TYPICAL LOG ANCHOR DETAIL

TYPICAL ROCK ANCHOR DETAIL

TYPICAL DUAL DOUBLE GUY ATTACHMENT DETAIL

NOTE: EYE OF ANCHOR ROD SHALL BE 6" TO 18" ABOVE GROUND. ROD SHALL BE ALIGNED TOWARD ATTACHMENT POINT ON STRUCTURE.

NOTE: EYE OF ANCHOR ROD SHALL BE 6" TO 18" ABOVE GROUND. ROD SHALL BE ALIGNED TOWARD ATTACHMENT POINT ON STRUCTURE.

NOTE: ANCHORING MAY BE ACHIEVED BY USE OF ROCK ANCHORS OR OTHER SUITABLE METHOD. CONTRACTOR SHALL DETERMINE EXISTING SUBSURFACE CONDITIONS AT EACH ANCHOR LOCATION, DETERMINE APPROPRIATE ANCHOR METHOD, AND SHALL SUBMIT ANCHOR DESIGN AND DETAILS TO ENGINEER FOR APPROVAL PRIOR TO START OF CONSTRUCTION.

NEUTRAL

36" MAX.

STAPLES SPACED 12" FOR FIRST 8 FEET

6" MINIMUM

PRJ.# - DWG.#:

3'-0" MINIMUM

KINGDOM COMMUNITY WIND TYPICAL POLE GROUNDING DETAIL

TYPICAL BOUNDED GUY DETAIL

27002 -104 ENGIN'D BY:

GREEN MOUNTAIN POWER LOWELL, VERMONT 0 NO.

ISSUED FOR BID REVISION/ISSUE

5/17/11 DATE

18 Meadow Road P.O. Box 722 Augusta, ME 04332 Phone 207-621-1077

34.5KV OVERHEAD THREE PHASE TRUNK LINE TYPICAL GUYING DETAILS

NSH DRAWN BY: CJL DATE: 5/16/11

RDE

RDCSB

RDE - RISER

TOP

TOP

TOP

TOP

TOP

TOP

BOTTOM

BOTTOM

BOTTOM

BOTTOM

BOTTOM

BOTTOM

BOTTOM

BOTTOM

TOP

TOP

20"

20"

RDEB

RLD

RDAR

TOP TOP

TOP

BOTTOM

TOP

BOTTOM

BOTTOM

BOTTOM

BOTTOM

BOTTOM

TOP

TOP

20"

PRJ.# - DWG.#:

KINGDOM COMMUNITY WIND

NOTE: SEE SHEET E-104 FOR ANCHORING DETAILS

27002 -105 ENGIN'D BY:

GREEN MOUNTAIN POWER LOWELL, VERMONT 0 NO.

ISSUED FOR BID REVISION/ISSUE

5/17/11 DATE

18 Meadow Road P.O. Box 722 Augusta, ME 04332 Phone 207-621-1077

34.5KV OVERHEAD THREE PHASE TRUNK LINE TYPICAL GUYING DETAILS

NSH DRAWN BY: CJL DATE: 5/16/11