PIC-A-WATT® / MULTI-PURPOSE / 950 or 6000 WATTS / CEILINGS UNDER 10 FT
LR43323
FEATURES: OPTIONS:
Pic-A-Watt® Element Cast Iron Motor Aluminum Fan Blade Built-in Thermostat Quiet Running
• 30 Amp plug, cord, handle kit • Remote thermostat (-RT) • 24 Volt control (-RTLV)
• Multiple wattage selection • Powder-coated finish • Standard color: almond • Universal mounting bracket • Fan delay • Selector switch - Fan / Heat / Off • Tested under UL1278 • Bi-metallic limit turns element off if an over temperature condition occurs then automatically resets when normal temperature returns
ENGINEERING SPECIFICATIONS:
The KBP is an excellent choice for a garage or shop heater with the capacity to easily heat a large space. The flow-through design moves air efficiently by pulling air from the back of the heater and discharging it out the front. This rugged heater has quality components suitable for commercial applications as well. It comes standard with a 3-position switch and an accurate built-in thermostat listing degrees on the label for precise temperature control. An included fan delay helps dissipate heat from the elements.
This heater can be purchased with optional (-K1) (120 Volt) or (-K2) (240 Volt) accessory kits.
Contractor shall supply and install KBP Series unit heaters manufactured Fan Delay Switch: The fan continues to operate after the thermostat shuts off in order to remove the residual heat left in the elements. by King Electrical Mfg. Company. Heaters shall be of the wattage and Power must not be interrupted. voltage as indicated on the plans. Universal Mounting Bracket: Combination ceiling/wall/floor bracket is included with every heater. Pic-A-Watt® Heating Element: Exclusive King multi-tap element allows field adjustment to several wattages at time of installation. Steel Unit Bearing Motor: Permanently lubricated, cast iron, 4 -Pole motor with 20 cc of oil. Enclosed rotor provides long-lasting, trouble-free sheath elements of various resistance are copper brazed to steel plate operation. Thermally protected. 1300 RPM. fins producing a multi-wattage heating element. Built-in Thermostat: Single Pole factory installed hydraulic capillary Auto-Reset Thermal Limit Control: Heater shuts off when an over temperature conditions exist and automatically resets when the normal tube thermostat with precision heating control. Operating range 40º operating temperature returns. to 90º F. Fan / Heat / Off Switch: 3-position switch provides heating and Exterior: Textured acrylic powder-coating provides an attractive durable finish in almond color. summer fan only operation. The DPST off switch provides a “positive off” that disconnects all ungrounded conductors. Not available in 480V Approval: cCSAus (LR43323) and 3-Phase models. Tested under UL1278
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738
www.king-electric.com
SELECTION:
380V-3Ø Heaters are available in most kW ratings
MODEL
UPC #093319 PART #
VOLTS
PHASE
WATTAGE RANGE
PHASE AMPS SINGLE / THREE
MOTOR SIZE
CFM
TEMP RISE (°F)
AIR THROW
WT. (lbs.)
KBP1230
15191
120
1
2850 • 1900• 950
24
5W
270
35°
16 ft.
26
KBP2406
15190
240*
1
5700 • 4750 • 3800 2850 • 1900 • 950
24
5W
270
70°
16 ft.
24
KBP2006-3MP**
15193
208
1-3
5700 • 2850
27 / 16
5W
270
70°
16 ft.
26
KBP2406-3MP**
15188
240*
1-3
5700 •2850
24 / 14
5W
270
70°
16 ft.
25
KBP2704
15187
277
1
4000 • 3000 2000 • 1000
15
5W
270
47°
16 ft.
26
KBP4804-3MP**
15196
480***
1-3
4160
9/5
5W
270
49°
16 ft.
26
KBP4806-3MP**
15197
480***
1-3
6000
13 / 8
5W
270
71°
16 ft.
26
* Approved for 208V operation. Heater will draw 13% less Amps and 25% less wattage ** 3-Phase units do not have Heat / Fan / Off *** 480 Volt models are 24 Volt control
* Factory installed only - Heat / Fan / Off activated at unit only - can not operate remotely
Standard Color: Textured Almond
INSTALLATION WIRING FOR REMOTE THERMOSTAT Power must be routed to heater first, then to remote thermostat. This is due to the fan delay circuit needed to cool the elements on shutdown.
24V Remote T-Stat
RTLV
Receptacle configurations included for cord set 30 Amp 120 Volt N.E.M.A. #5-30P Model KBP-K1
King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738
10-13
Hobby Greenhouse Kits
Propagation Supplies
Greenhouse Gardening Tips
Garden Supplies
Portable Greenhouses
Sign up for our Gardening Email
INSTALLATION & MAINTENANCE MANUAL Model:
KBP2406
240V-1phase Unit Heater
WARNING
Unpack & Inspect Your New Heater
Model: KBP2406 is 240 volt. It is important that you verify the power supply voltage is the same as the nameplate voltage of the heater. Improper installation or failure to follow the procedures as outlined in this manual can result in damage to the heater. Note that the KBP2406 will operate at 208 volt but will produce 25% less wattage and draw 13% less Amps. Disconnect all power from the heater at the main service panel before attempting to install or service this unit. All electrical wiring must conform to local electrical codes. Heater circuit must be properly protected.
Remove heater from box and inspect it for any damage. Verify you have received the mounting bracket and accessories.
Mounting Heater
Tools Needed
Locate a stud in ceiling or wall and securely fasten bracket with a minimum of two #12 fasteners 1-1/4" long. Attach heater to bracket with 3/8" x 1" wingnut & lock washer supplied. Install the lock washer between the bracket and heater. Do not put lock washer on the plastic wingnut. After desired air discharge position has been determined tighten wingnut so heater will not pivot.
You will need the following tools to install your unit heater: -Screwdriver - (Phillips & Slotted) -Wire Cutters -Pliers -Adjustable Wrench -Electric Drill
Hardware Needed You will need the following hardware: -Adequate gauge & length of wire for your application -Proper size fuses or breakers to handle amperage -Proper wire connectors for your application -Appropriate size fasteners to mount heater.
Location of Heater The heater should be installed out-of-reach of persons. The direction of airflow should not be restricted by machinery, beams, etc. and the airflow should wipe exposed walls, rather than blowing directly at them. When more than one heater is used in an area the heaters should be arranged so that the air discharge of each heater supports the airflow of the others to provide best circulation of warm air. (see airflow chart)
In certain applications conduit may be required by code. Check local electrical codes. If you want to be able to turn the heater be sure to use flexible conduit.
Mounting Height When the air flow of the heater is directed vertically or horizontally the minimum mounting height is 6 feet in USA and 8 feet in Canada. Mounting heights depend upon building utilization and heater kW capacity.
Distance From Walls Maintain 6" minimum clearance to side walls and 2" to ceiling in back of the heater (air intake side). Maintain 18" clearance in front of the heater (discharge side). 2007KBP2406.indd : 3/08
INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If the alarm flashes immediately turn the heater off and inspect for any objects on or adjacent to the heater that may cause high temperatures. Do not operate the heater with the alarm flashing.
21¾"
13"
½" Safety Light
RED
This heater is shipped from the factory wired for maximum wattage of 2750 Watts at 120 Volts. To reduce the wattage unplug (disconnect) an insulated push on terminal and wrap with electrical tape to prevent the possibility of electrical contact with other parts.
A - ORANGE B - BLUE C - YELLOW D - BLACK E - RED
Disconnects 750 Watts Disconnects 500 Watts Disconnects 250 Watts Do Not Disconnect (Common) Do Not Disconnect
YELLOW
750 WATT B
D
500 WATT C
250 WATT
Insulated Push on Terminal ORANGE RED #14
Feild Wattage Selection
BLUE
E
BLACK #14
INSTALLATION INSTRUCTIONS
RED
A
750 WATT E
D
500 WATT
Insulated Push on Terminal
VISUAL ALARM
FAN DELAY 2
1
BLACK#16
LIMIT
BLACK #16 FAN
3 ORANGE#14
E
B
C
750
500
250
Thermostat Connections
PURPLE #16
Pic-A-Watt Metal Sheath Element
D Common A
E
750
500
E
END VIEW OF ELEMENT SHOWING QUICK CONNECT TERMINALS
1250 • 1500 • 1750 • 2000 • 2500 • 2750 WATTAGES AVAILABLE IN ONE UNIT
ORANGE #14
GRAY #16 ORANGE#14
1
2
OFF ....... L1-0, L2-0 FAN ....... L1-2, L2-4 HEAT...... L1-1, L2-4, L2-3 FAN DELAY 1-3 N.C. , 1-2 N.C. 1-2 Closes on Temp Rise
LPW1227
L1
3
Rotary Switch
4
L2
BLACK
D Common
L1
L2 LPW1227.indd : 4/08
OWNERS GUIDE & INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH HEATER FOR HOME OWNER KING ELECTRICAL MFG. COMPANY • 9131 10th Ave So. • Seattle, WA 98108 • Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com