Universal Lighting Technologies Navigator

Report 4 Downloads 75 Views
• Instant Starting Options

T8HO

• 1-2 Lamp Applications

Fluorescent-Electronic

Lamp Starting Line Catalog Qty. Method Volts Number F48T8HO - One Lamp Applications 120 B286I120RH 1 IS 277 B286I277RH F60T8HO - One Lamp Applications 120 B286I120RH 1 IS 277 B286I277RH F72T8HO - One Lamp Applications 120 B286I120RH 1 IS 277 B286I277RH F96T8HO - One Lamp Applications 120 B286I120RH 1 IS 277 B286I277RH F48T8HO - Two Lamp Applications 120 B286I120RH 2 PAR-IS 277 B286I277RH F60T8HO - Two Lamp Applications 120 B286I120RH 2 PAR-IS 277 B286I277RH F72T8HO - Two Lamp Applications 120 B286I120RH 2 PAR-IS 277 B286I277RH F96T8HO - Two Lamp Applications 120 B286I120RH 2 PAR-IS 277 B286I277RH

11.75”

3.13”

Certification NOM

11.14”

Min. F/C Start Wiring Temp Diag. Dim.

• •

• •

• •

0.47 0.20

48 47

> .90 > .90

1.00 1.00

2.08 2.13

< 30 -20/-29 < 30 -20/-29

3 3

SL SL

• •

• •

• •

0.56 0.23

60 57

> .90 > .90

0.99 0.98

1.65 1.72

< 30 -20/-29 < 30 -20/-29

3 3

SL SL

• •

• •

• •

0.64 0.26

71 67

> .90 > .90

0.98 0.98

1.38 1.46

< 30 -20/-29 < 30 -20/-29

3 3

SL SL

• •

• •

• •

0.79 0.32

92 87

> .90 > .90

0.96 0.93

1.04 1.07

< 25 -20/-29 < 25 -20/-29

3 3

SL SL

• •

• •

• •

0.70 0.30

80 77

> .95 > .90

0.85 0.84

1.06 1.09

< 25 -20/-29 < 25 -20/-29

3 3

SL SL

• •

• •

• •

0.85 0.36

99 96

> .95 > .95

0.85 0.84

0.86 0.88

< 20 -20/-29 < 20 -20/-29

3 3

SL SL

• •

• •

• •

1.00 0.42

117 114

> .95 > .95

0.85 0.84

0.73 0.74

< 20 -20/-29 < 20 -20/-29

3 3

SL SL

• •

• •

• •

1.30 0.53

151 144

> .95 > .95

0.81 0.81

0.54 0.56

< 20 -20/-29 < 20 -20/-29

3 3

SL SL

Mounting Dimensions H M X 1.78”

Line Input Power Ballast Ballast Current Power Factor Factor Efficacy THD (Amps) (Watts) (PF) (BF) Factor (BEF) %

STARTING METHOD LEGEND PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start

IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start

SL

FOR (1) AND (2) F48T8HO, F60T8HO, F72T8HO AND F96T8HO LAMPS

• 4-8’ T8 High Output

High Output Lamps

Overall Dimensions Draw # L W

TRIAD® ELECTRONIC BALLASTS

PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start

WIRING DIAGRAMS

2.00”

For One Lamp Operation, Insulate one blue lead to 600V

DIAGRAM 3

Page 2-34

FOR MORE INFORMATION CALL

1-800-BALLAST (225-5278)

Fluorescent-Electromagnetic

Product Overview Rapid Start Ballasts These ballasts provide smooth starting to Rapid Start lamps — reaching full brightness in about two seconds without the use of starters. They have built-in filament windings that energize the low-voltage cathodes in Rapid Start lamps. Because electrodes are continuously heated, less voltage is required to strike an arc through a Rapid Start lamp than a Slimline one. Ballasts for T12/T10 Applications Universal offers a wide variety of T12 and T10 ballasts to operate 1 - 3 Rapid Start lamps. This lamp/ballast system provides smooth, virtually instant starting without the use of starters (30and 40-watt T12 models and 40-watt T10 models are available). Models for U-lamp applications are also available. UNIVERSAL® PLUS models are available for use where maximum efficiency is required. These "hybrid" type ballasts in corporate an electronic switch which disconnects power to the lamp cathodes after start-up, saving additional energy. Ballasts for T8 Applications Universal's T8 product offering includes models for F17, F25, F32 and F40 type T8 lamps. This product line features our OcTek™ electromagnetic ballast models. These models are low initial cost energy efficient options for use with F32T8, 4 foot Rapid Start lamps. These models are available in several variations, including full, medium, low light output and hybrid versions (OcTek™ Plus). These models maximize energy savings and provide effective choices when retrofitting 4-foot T12 fixtures. Slimline Ballasts Our Slimline models are designed for use with single-pin Slimline lamps. They do not require the use of starters. These ballasts deliver a high starting voltage to the lamps, enabling an arc to strike through the tube without preheating the lamp cathodes (which are specially constructed to withstand the shock).

PAGE 1-2

Rapid Start Ballasts

T12/T10 Applications

T8 Applications

Slimline Ballasts

FOR MORE INFORMATION CALL

1-800-BALLAST (225-5278)