V-Series Incandescent Luminaires 1L

Report 1 Downloads 113 Views
900-901.qxp

12/16/2013

6:44 PM

Page 900

Wet Locations NEMA 3, 3R

V-Series Incandescent Luminaires

1L

Enclosed and Gasketed Applications:

Standard Materials:

V-Series incandescent luminaires are used: • Indoors or outdoors in industrial locations where enclosed and gasketed fixtures are required • In tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem • For flush or surface mounting on ceiling or wall, with or without a cast outlet box, pendant or in conduit systems

• • • •

Features:

Bodies – Feraloy® iron alloy Guards – copper-free aluminum Globes – glass Reflectors – Krydon® fiberglassreinforced polyester material reflectors

Standard Finishes: • Feraloy iron alloy – electrogalvanized and aluminum acrylic paint • Copper-free aluminum – natural • Krydon® material – high reflectance white

Options:

• Designed to exclude dirt, moisture and corrosive vapors from the interior of the fixtures and the conduit system • Several body styles provide a wide variety of mountings, while all use the same globes, guards and optional accessories • Rugged and corrosion resistant

Size Ranges:

Certifications and Compliances:

• 3/4 hubs • Maximum wattage lamp: – Glass globes 150W, A23 – Polycarbonate 75W, A33

Description Corro-free™ epoxy powder coat

Suffix S752

Plastic polycarbonate globe

Order separately. See below

1L

• Wet locations • NEMA: 3, 3R • UL Standard: 1598

Description

VDA

VC

VG

VJ

VD

Cat. #

Cat. #

Cat. #

Cat. #

Cat. #

With plain globe and guard

VDA2759

VC2759

VG2759

VJ2759

VD2759

Without globe and guard

VDA275

VC275

VG275

VJ275

VD275

Glass Globes and Guards

Polycarbonate Globes Applications: Polycarbonate globes are used: • In food processing plants, canneries, dairies, breweries and bakeries • In emergency lighting • Emergency police and fire alarm boxes

V63 Color Clear (heat resisting) Green Blue Red Amber 900

V911 Cat. #

Globe Size

V63

6 /4" 3

Cat. # V911

VN72 VN73 VN75 VN76 www.crouse-hinds.com

US: 1-866-764-5454

Features: • Polycarbonate globes are shatterproof, preclude contamination of food products with broken particles of glass • Comply with U.S. Dept. of Agriculture specification for food processing plants

CAN: 1-800-265-0502

V470 Color

Cat. #

Natural Red

V470 V475

Copyright© 2013 Eaton’s Crouse-Hinds Business

900-901.qxp

12/16/2013

6:44 PM

Page 901

1L

Incandescent Luminaires Accessories and Parts For V-Series

Reflectors

Receptacles

Krydon® – fiberglass-reinforced polyester (Must be used with V911 Guard)

(medium base)

Dome

Description

Cat. #

Medium Base Receptacle

V46

Gasket

Angle Lamp Size Dome 50–150W 30°Angle 50–150W Note:

Dia.

Cat. #

12"

RD60

12"

RA60

Description

Cat. #

Gasket

GASK213

Angle reflector cannot always be used with bracket style fixtures. Check distance from mounting surface to center of body against reflector size to determine if reflector will fit.

1L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

901

902-903.qxp

12/16/2013

6:44 PM

Page 902

V-Series Incandescent Luminaires

1L

Enclosed and Gasketed Dimensions Dimensions In Inches:

VC

VD

a

c

d

h

k

/8 7 /8

311/16 311/16

4 4

63/16 63/16

49/16 49/16

7

Hub Size 1 /2 3 /4

a

b

c

g

h

k

415/16 415/16

43/16 43/16

515/16 63/16

21/2 23/4

63/16 63/16

49/16 49/16

1L

Hub Size 1 /2 3 /4

VDA

VG Hub Size 1 /2 3 /4

902

VJ

c

h

k

47/8 47/8

63/16 63/16

49/16 49/16

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Hub Size 1 /2 3 /4

b

c

d

e

h

k

113/16 113/16

47/8 47/8

3

/8 3 /8

53/8 53/8

63/16 63/16

49/16 49/16

Copyright© 2013 Eaton’s Crouse-Hinds Business

902-903.qxp

12/16/2013

6:44 PM

Page 903

V-Series Incandescent Luminaires

1L

Photometric Data

Enclosed and Gasketed Luminaires V-Series Lamp: 150W/A23 Clear Total Bare Lamp Lumens: 2800 All data provided is for 150W incandescent lamp. Use following candela/lumen multipliers for the other lamp sizes: 100W – 0.61

Example: Zonal lumens for 150W lamp for 0–40° with guard is 252.

Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall

Room Cavity Ratio 1 2 3

4

5

50 30 10

.659 .623 .591

.558 .504 .458

.479 .417 .367

.416 .349 .298

.361 .298 .248

70

50 30 10

.609 .577 .545

.515 .466 .426

.442 .386 .342

.384 .324 .278

.336 .275 .230

50

50 30 10

.515 .491 .469

.434 .397 .364

.372 .328 .293

.321 .274 .238

.282 .234 .197

30

50 30 10

.429 .411 .395

.359 .332 .307

.307 .274 .245

.264 .228 .198

.232 .194 .165

10

50 30 10

.350 .337 .325

.290 .269 .251

.246 .221 .199

.211 .183 .160

.185 .156 .132

Room Cavity Ratio 6 7 8

9

10

80

50 30 10

.325 .259 .212

.290 .227 .183

.261 .199 .157

.236 .176 .136

.211 .153 .116

70

50 30 10

.299 .240 .197

.268 .210 .170

.241 .186 .146

.219 .164 .127

.194 .143 .108

50

50 30 10

.252 .205 .169

.226 .178 .145

.203 .158 .125

.185 .140 .109

.165 .122 .092

30

50 30 10

.208 .170 .141

.186 .149 .121

.169 .131 .105

.153 .117 .091

.137 .101 .076

10

50 30 10

.167 .136 .114

.151 .121 .098

.135 .106 .084

.124 .094 .073

.110 .081 .060

% Reflectance Eff. Ceil. Wall

www.crouse-hinds.com

US: 1-866-764-5454

1L

80

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

903