Vertical Discharge Remote Condenser Vertical Discharge Remote C ...

Report 2 Downloads 78 Views
TS-0895 Remote Condenser

Remote, air-cooled condenser system conserves energy and improves beverage cooling efficiency.

Multiplex remote condenser systems effectively dissipate heat at a convenient location, indoors or outdoors, away from the chiller. This maximizes beverage cooling capability and minimizes air conditioning loads by lowering the ambient air temperature at the chiller.

Standard Features • One size for all remote condenser Multiplex chillers. • Vertical discharge remote condenser is available for Multiplex Model 50 and Model 44. Refer to specification sheet for equipment dimensions, production capacities and electrical requirements. • Condenser operation range from -20°F (-29°C) to 120°F (49°C). Can be installed with up to 15" (38.1 cm) of bottom clearance.

ISO 9001:2000 Quality System Certified

2100 Future Drive

Tel: 812.246.7000

Sellersburg, IN 47172 USA

Fax: 812.246.7024

www.manitowocbeverage.com/us

Vertical Discharge Remote Condenser

For Multiplex Chillers

For Multiplex Chillers

Vertical Discharge Remote Condenser

Standard Interconnecting Refrigerant Lines

Maximum Location Distance—combined vertical and horizontal distances from chiller to condenser must comply with guidelines.

Model

Line Length

Weight

Maximum Line Length: 100' (30 m)*

Maximum Vertical Rise: 100' (30.5 m) above chiller - requires an oil trap every 25' of vertical rise if not terminated in a condenser.

RT-20-R-404A

Maximum Vertical Drop: RT-35-R-404A

100' (30.5 m) below chiller

RT-50-R-404A

To calculate other acceptable horizontal and vertical combinations, refer to remote condenser installation instructions.

20 ft.

11 lbs..

600 cm.

5 kgs.

35 ft.

17 lbs..

1,050 cm.

8 kgs.

50

24 lbs..

1,500 cm.

11 kgs.

Electric Electrical power to the remote condenser is intended to be supplied from the Multiplex chiller. Condenser

Model

Electrical Service

TS-0895

44 or 50

208-230/60/50/1

Weight 85 lbs.. 39 kgs.

m)

28

3c

2.2

(6 0"

.00

" (7

1.1

4.5

2 Optional 34.00" (86.36 cm) or 30.00" (76.20 cm)

2c

m)

E

D

Electrical Entrance

C Discharge Refrig. Line

B F

A 29

G

.16

" (7

4.0

Liquid Refrig. Line

6c

m) TS-0895 Remote Condenser

A B C D

2100 Future Drive Sellersburg, IN 47172 USA

6.00" (15.24 cm) 3.50" (8.89 cm) 3.88" (9.85 cm) 12.13" (30.81 cm)

Tel: 812.246.7000 Fax: 812.246.7024 www.manitowocbeverage.com/us

E F G

1.50" (3.81 cm) 6.50" 16.51 cm) Optional 20.00" (50.80 cm) 16.00" (40.64 cm) 12.00" (30.48 cm)

of specifications without notice.

*230/50/1 available. Consult factory. HACR circuit breakers can be used in place of fuses.

3961C ©2012 Multiplex 3/12 Continuing product improvement may necessitate change

Vertical Discharge Remote Condenser

For Multiplex Chillers

Installation Information and Dimensions