Viking Installation Guide - Viking Range

Report 0 Downloads 142 Views
Viking Installation Guide

Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200

For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com

Electric Induction Rangetops F20115A

(PS032607JJ)

IMPORTANT – Please Read and Follow!

General Information

• Before beginning, please read and follow these instructions completely and carefully.

• All openings in the wall behind the appliance and/or in the floor under the appliance should be sealed. • Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors. • Disconnect the electrical supply prior to servicing and/or cleaning. • When removing the appliance for service and/or cleaning, disconnect AC power supply and carefully remove the appliance by pulling forward. • Electrical requirements are listed in the product specifications chart. Electrical installation should comply with national and local codes. • DO NOT remove protective packaging until you are ready to perform the installation.

WARNING This appliance should not be used for space heating. This information is based on safety considerations.

• Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty.

WARNING

• Please observe all local and national codes and ordinances.

ELECTRICAL GROUNDING INSTRUCTIONS This appliance must be electrically in accordance with local codes, or in the absence of local codes, the National Electrical ANSI/NFPA 70, latest edition.

• Please ensure that this product is properly grounded. • Installation must conform with local codes, or in the absence of codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

• In CANADA: Electrical installation must be in accordance with the current CSA C22.2 Canadian Electrical Codes Part 1 and/or local codes.

CAUTION Be sure all electrical power is off between the breaker box and the junction box, until the unit is installed and ready to operate. The junction box should be connected to a suitable ground.

Electrical Connection

WARNING Electrical power to the unit must be shut off while line connections are being made. Failure to do so could result in serious injury or death. When making the wire connections, use the entire length of the conduit provided (3 feet). The conduit must not be cut. Connect the red and black leads from the unit conduit to the corresponding leads in the junction box. The bare ground wire in the conduit is connected to the unit frame. When connecting to a 3conductor branch circuit, if local codes permit, connect the bare ground connector lead of the unit to the branch circuit neutral (gray or white in color).

Electrical Requirements

• Installer should leave these instructions with the consumer who should retain for local Inspector’s use and for future reference.

Check your national and local codes regarding this unit. This rangetop is supplied with a 3 wire, 240/208 VAC, 60 Hz conduit which is equipped with a No. 10 ground wire. See electrical connection section for grounding instructions. This unit should be fused separately.

• Consumer should retain this guide for the local Electrical Inspector’s use.

DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. SUCH USE MAY RESULT IN A FIRE, ELECTRICAL SHOCK OR OTHER PERSONAL INJURY.

WARNING The use of cabinets for storage above the appliance may result in potential fire or burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided, the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets.

Back Trim Accessories Assembly and installation instructions are included with all back trim accessories.

1

2

Dimensions & Specifications

Dimensions & Specifications All Induction Rangetop

Induction/Radiant Rangetop Description Overall Width Overall Height From Bottom

VCRT301 29 7/8” (75.9 cm) BASE HEIGHT To top of glass frame 7 7/8” (20.0 cm)

Overall Depth From Rear

Description

VCRT361 35 7/8” (91.1 cm) ADDITIONS TO BASE HEIGHT To top of island trim - add 1 1/4” (3.2 cm) To top of backguard - add 6” (15.2 cm) To top of high-shelf - add 23 1/2” (59.7 cm)

30” (76.2 cm)

35 7/8” (91.1 cm) ADDITIONS TO BASE HEIGHT To top of island trim - add 1 1/4” (3.2 cm) To top of backguard - add 6” (15.2 cm) To top of high-shelf - add 23 1/2” (59.7 cm)

To edge of side panel - 24” (61.0 cm) To end of control panel - 25 15/16” (65.9 cm) To end of knobs - 27 7/16” (69.7 cm)

Cutout Width

36” (91.4 cm)

VIRT361

29 7/8” (75.9 cm) BASE HEIGHT To top of glass frame 7 7/8” (20.0 cm)

Overall Depth From Rear

To edge of side panel - 24” (61.0 cm) To end of control panel - 25 15/16” (65.9 cm) To end of knobs - 27 7/16” (69.7 cm)

Cutout Width

Overall Width Overall Height From Bottom

VIRT301

30” (76.2 cm)

36” (91.4 cm)

Cutout Height

7 1/2” (19.1 cm)

Cutout Height

7 1/2” (19.1 cm)

Cutout Depth

24” (61.0 cm)

Cutout Depth

24” (61.0 cm)

Electrical Requirements

3 - Wire, 240/208 VAC, 60 Hz, electrical connection. Unit is equipped with No. 10 ground wire in conduit. Should be fused separately.

Maximum Amps

240v - 37.9 amps 208v - 32.8 amps

Surface Element Rating

Approx. Shipping Wt.

240v - 55.0 amps 208v - 50.2 amps

240V

208V

Left Front Left Rear

2500 watts 1500 watts

1875 watts 1125 watts

Right Front Right Rear

1200 watts 3300 watts

900 watts 2475 watts

110 lbs. (49.5 kg)

Left Front Left Rear Center Front Bridge Center Rear Right Front Right Rear

240V

208V

2200 watts 1500 watts 1800 watts 800 watts 1800 watts 1200 watts 3300 watts

1650 watts 1125 watts 1350 watts 600 watts 1350 watts 900 watts 2475 watts

125 lbs. (56.2 kg)

Electrical Requirements

3 - Wire, 240/208 VAC, 60 Hz, electrical connection. Unit is equipped with No. 10 ground wire in conduit. Should be fused separately.

Maximum Amps

240v - 37.9 amps 208v - 32.8 amps

Surface Element Rating

Approx. Shipping Wt.

240v - 56.3 amps 208v - 56.3 amps

240V

208V

Left Front Left Rear

2500 watts 1500 watts

1875 watts 1125 watts

Right Front Right Rear

1200 watts 3300 watts

900 watts 2475 watts

110 lbs. (49.5 kg)

240V Left Front Left Rear Center Front Center Rear Right Front Right Rear

2700 1800 2700 1800 1200 3300

208V watts watts watts watts watts watts

2025 watts 1350 watts 2025 watts 1350 watts 900 watts 2475 watts

125 lbs. (56.2 kg)

Minimum Clearance from adjacent combustible construction • Cooking surfaces and below (36” [91.4 cm] and below) • Sides - 0” • Rear - 0” with backguard or highshelf; 0” with island trim and non-combustible wall; 6” (15.2 cm) with island trim and combustible rear wall • Top grate support - 36” (91.4 cm) • Above cooking surface (above 36” [91.4 cm]) • Sides - 6” (15.2 cm) • Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm) above cooking surface. • Wall cabinets directly above product must be minimum 36” (91.4 cm) above cooking surface.

3

4

Installation

Clearances

Proximity to cabinet installation

Interior Cabinet Clearances for proper airflow

1. This rangetop may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets. 2. The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the rangetop to such combustible surfaces above the 36” (91.4 cm) counter height. 3. Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop. 4. Wall cabinets above the rangetop must be a minimum of 36” (91.4 cm) above the rangetop cooking surface for the full width of the rangetop.

Detailed View of Bottom Support 2 3/4” (7.0 cm)

1 1/2” dia. cutout for conduit

3” (7.6 cm)

2” (5.1 cm)

8” (20.3 cm)

8” (20.3 cm)

SIDE

FRONT 3” (7.6 cm)

1 1/2” (3.8 cm) Remove the material from this area for proper air flow into the unit. 13” Max 36” Min. (91.4 cm)

(33.0 cm)

7 1/2” (19.1 cm)

6” Min. (15.2 cm)

36” Min. (91.4 cm)

5

18” Min. (45.7 cm)

IMPORTANT: The electronic components for the induction elements in the rangetop need some air circulation. To ensure long life of electronic components, it is required that a minimum of 8” (20.3 cm) of open space remain between the bottom of the unit and any shelf underneath. The maximum length of the shelf underneath is to be 18” (45.7 cm) There should be no partition or shelf directly underneath the unit.

8” Min. (20.3 cm) 18” Max. (45.7 cm)

6

Final Preparation 1. The interior of the oven should be washed thoroughly with hot, soapy water to remove film residues and installation debris before being used for food preparation, then rinsed and wiped dry. Solutions stronger than soapy water are rarely needed. 2. Some stainless steel parts may have a plastic protective wrap, which must be removed. All stainless steel body parts should be washed with hot soapy water and with liquid cleaner designed for this material. If build-up occurs, do not use steel wool, abrasive cloths, cleaners or powders! If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wood or nylon scraper. Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel!! Scratches are almost impossible to remove.

Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted on the inside of the water tank opening. Model number _________________________________________

Serial number _________________________________________

Date of purchase _________________________________________

Date installed _________________________________________

Dealer's name _________________________________________

Address

Service & Parts

_________________________________________

Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.

These installation instructions should remain with the unit for future reference.

Contact Viking Range Corporation, (888) 845-4641, for the nearest service parts distributor in your area.

7

8

Electric All Induction 30” Wide Rangetop Wiring Diagram L2 RED

L1

BLACK

CHASSIS GROUND GREEN

L2C L1C

L2R L1R

POWER LINE CONDITIONER

WHITE

J4

BLUE

J3

J2

J1

POWER BOARD

POWER BOARD

J16

RED BLACK

JOUT1 JOUT2

J17

J3

JE3

AC FAN

JE4

J6

J14

J7

J15

RED SMALL COIL

BLACK

J8

JE5

VIO

SMALL COIL POTENTIOMETER

JE3

GRAY

JE6

RED

RED

J10

BLACK

REAR

JE2 J12 JE7

JE8

LARGE COIL POTENTIOMETER

J13 J2 BLACK RED

JOUT3

J18 J19

JOUT4

BROWN

JE5

VIO

JE6

GRAY

J9

RED

J8

BLACK

REAR

J11

RED

J10

BLACK

FRONT

JE2 J12 JE7

JE8

LARGE COIL POTENTIOMETER

J13 J2

RED

JOUT3

J18 J19

JOUT4

RIGHT SECTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

9

SMALL COIL POTENTIOMETER

LED BOARD

J4 J5

CAUTION

This unit must be properly grounded. See installation instructions for proper grounding instructions. NOTE: Trailers or stripes will be the second color in a color combination.

TEMP CONTROL

JE1

BLACK LARGE COIL

SMALL COIL

J14 J15

J7

TEMP CONTROL

LEFT SECTION

WARNING

J6

EMI BOARD

BLACK

J11

AC FAN

JE4

FRONT

LED BOARD

J4 J5

JOUT2 J3

ORG

EMI BOARD

JOUT1

J17

TEMP CONTROL

JE1 J9

J16

10

TEMP CONTROL

LARGE COIL

Electric Induction/Radiant 30” Wide Rangetop Wiring Diagram L1

L2

BLACK

RED

RED/BLK

RED/BLK

YEL/RED

YEL/RED

WH/RED

RED

RED

BLACK

1500 WATT L.R. ELEM.

RED/BLK

CHASSIS GROUND GREEN

L1

PURPLE

P

BLK WH/RED L2C L1C

RED

L2R

L1R

J2

J1

L2

H1

H2

(H2)

(H1)a

POWER LINE CONDITIONER J4

J3

RED/YEL (H1)b

POWER BOARD

P L2

J16

JOUT1

J17

JOUT2 J3

JE3

ORG

AC FAN

JE4

J6

J14

J7

J15

2500/1000 WATT L. F. ELEM.

ORG

BROWN

RED/BLK RED TEMP CONTROL SMALL COIL POTENTIOMETER

JE1

EMI BOARD JE5

VIO

J4

JE6

GRAY

J5

J9

RED

J8

BLACK

WHITE

J10

YELLOW

FRONT

JE2

JE7

RED/BLK

REAR LED BOARD

J11

J12

BLK

L1

SMALL COIL

PURPLE

BLACK

ORG

RED

JE8

ORG

J2 BLACK

BLK/WH

LARGE COIL POTENTIOMETER

J13

RED

J18

JOUT3

J19

JOUT4

TEMP CONTROL

LARGE COIL

RED

PURPLE

RED

RED

SURF. ELEM. POWER ON LIGHT

ORG

RED RED/BLK

RED/BLK RED

WH/BLK YEL/BLK

WARNING

WH/BLK YEL/BLK

CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

This unit must be properly grounded. See installation instructions for proper grounding instructions. NOTE: Trailers or stripes will be the second color in a color combination.

11

12

Electric All Induction 36” Wide Rangetop Wiring Diagram L2 RED

L1 BLACK

CHASSIS GROUND GREEN

L2L

L1L

L2C L1C

L2R

L1R

POWER LINE CONDITIONER J6

J5

J4

J3

J2

J1

WHITE BLUE

POWER BOARD

RED BLACK

J16

JOUT1

J17

JOUT2 J3

JE3

YELLOW

AC FAN

JE4

J6

BLACK

VIO

J4

JE6

GRAY

J5

JOUT1

J17

JOUT2 J3

SMALL COIL POTENTIOMETER

JE1

JE5

J16

TEMP CONTROL

J15

EMI BOARD

WHT/RED

RED

SMALL COIL (FRONT)

J14

J7

POWER BOARD

POWER BOARD

J9

WHITE

J8

YELLOW

RED

J10

BLACK

JE4

J6

J14

J7

J15

BLACK

JE5

VIO

J4

SMALL COIL POTENTIOMETER

JE2

JE6

GRAY

J5

J9

RED

J12 JE8

LARGE COIL POTENTIOMETER

J13

J8

BLACK

J11

WHITE

J10

YELLOW

J2 BLACK RED

J18

JOUT3

J19

JOUT4

J12 JE7

JE8

J2

BLACK

LARGE COIL (REAR)

RED

LEFT SECTION

J18

JOUT3

J19

JOUT4

AC FAN

JE4

J15

REAR

BROWN

VIO

J4

JE6

GRAY

J5

SMALL COIL POTENTIOMETER

J9

WHITE

J8

YELLOW

REAR LED BOARD

J11

RED

J10

BLACK

J12 JE7

JE8

FRONT

LARGE COIL POTENTIOMETER

J13

TEMP CONTROL

J2 BLACK

LARGE COIL (FRONT)

TEMP CONTROL

JE2

RED

J18

JOUT3

J19

JOUT4

RIGHT SECTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

13

J7

JE5

CAUTION

This unit must be properly grounded. See installation instructions for proper grounding instructions. NOTE: Trailers or stripes will be the second color in a color combination.

J14

SMALL COIL (FRONT)

JE1

CENTER SECTION

WARNING

J6

EMI BOARD

LARGE COIL POTENTIOMETER

J13

TEMP CONTROL

JOUT2

FRONT

JE2

JE7

JE3

LED BOARD

FRONT

JOUT1

J17

J3

ORG

EMI BOARD

J16

TEMP CONTROL

JE1

REAR LED BOARD

J11

JE3

AC FAN

RED SMALL COIL (REAR)

14

TEMP CONTROL

LARGE COIL (REAR)

Electric Induction/Radiant 36” Wide Rangetop Wiring Diagram L1

L2

BLACK

RED

RED/BLK

RED/BLK

YEL/RED

YEL/RED

WH/RED

RED

WH/RED

RED/BLK

RED/BLK

BLACK

RED

1500 WATT L.R. ELEM.

RED/BLK

CHASSIS GROUND GREEN PURPLE

WH/RED

L2R

L2C L1C

L

P

YEL/RED

BLK

RED

1

L2

LEFT REAR H2

H1

L1R

POWER LINE CONDITIONER J4

J1

J2

J3

(H1)a

(H2)

RED/YEL (H1)b

POWER BOARD

LEFT FRONT

P

1800 WATT SMALL COIL (FRONT)

BLK BRIDGE ELEM

JE3

1800 WATT

ORG

AC FAN

JE4

J6

J14

J7

J15

WH/BLK

RED/YEL

ORG

ORG

JE5

VIO

J4

JE6

GRAY

J5

J9

RED

J8

BLACK

REAR

RED

RED/BLK

RED

L

P

1

WHITE

MIDDLE REAR H1

J10

YELLOW

FRONT (H1)a

(H2)

JE7

JE8

LARGE COIL POTENTIOMETER

J13 J2

MIDDLE FRONT

(H1)b

TEMP CONTROL

P

RED

J18

JOUT3

J19

JOUT4

LARGE COIL (REAR)

L1

RED/BLK RED

YEL/BLK

BLK/WH

BLK/WHT

L2

BLACK

RED

H2

JE2

ORG

RED

L2

LED BOARD J11

J12

RED/BLK

BLK

SMALL COIL POTENTIOMETER

JE1

EMI BOARD

BROWN

TEMP CONTROL

RED/BLK

YEL/RED

J3

PURPLE

JOUT2

WH/RED

JOUT1

J17

ORG

BLACK

J16

800 WATT

2200/1000 WATT L. F. ELEM.

L1

L2

RED

PURPLE

SURF. ELEM. POWER ON LIGHT

ORG RED

RED

RED RED/BLK

RED/BLK RED WH/BLK

WH/BLK

YEL/BLK

YEL/BLK

WARNING

CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

This unit must be properly grounded. See installation instructions for proper grounding instructions. NOTE: Trailers or stripes will be the second color in a color combination.

15

16