VL - Columbia Lighting

Report 2 Downloads 156 Views
VL

Vandal Resistant Wrap / 2-Lamp T5, T5HO, T8 PROJECT INFORMATION Project Name

Type

Catalog No.

Date

CONSTRUCTION

Heavy 16 gauge cold rolled steel housing with formed end caps welded to housing. BALLASTS

Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant.

FEATURES • • • • • • • •

ELECTRICAL

Ideal for high abuse areas Effective, secure illumination mounts to ceilings or walls Rugged heavy duty steel construction Diffuser is .187" thick clear prismatic polycarbonate for highimpact protection Six tamper-resistant screws for maximum security Closed cell gasketing inhibits entry of airborne contaminants or insects Backpan is only 5/8" deep to hug walls or ceilings and deter vandals Optional stand-off mounting box permits surface conduit entry

Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.

FINISH

Painted parts are treated with a five stage phosphate bonding process and finished with a high reflectance baked white enamel. SHIELDING

Diffuser is of 0.187" thick clear prismatic polycarbonate material. CERTIFICATION

All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.

ORDERING INFORMATION VL

4

MODEL

SIZE

NO. OF LAMPS

VL Vandal Resistant Wrap

4 4'

2 Two

EXAMPLE VL4-232-EU

2



– LAMP TYPE 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28 or 25 Watt 54 4', T5HO: 54 or 51 Watt

– BALLAST

VOLTAGE

E Electronic T8, Instant Start EP Electronic T5 or T8, Programmed Start For a specific ballast vendor, show as option. Note: Certain non-standard ballast cases may not fit the VL. Contact factory for details.

U 120V-277V 347 347V

OPTIONS GLR Fast Blow Fuse WL Wet Location (Ceiling only) EL Emergency Battery Pack T8 350-450 Lumens EL5 Emergency Battery Pack T5 390-700 Lumens

ACCESSORIES (ORDER SEPARATELY) VLSC Surface Conduit Entry Box VLTS Tamper Resistant Screwdriver Note: Certain non-standard ballast cases may not fit the VL. Contact factory for details.

Page 1/2 Rev. 06/19/17

WRAPS / VL

© 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com

VL

Vandal Resistant Wrap / 2-Lamp T5, T5HO, T8

PHOTOMETRIC DATA

Test HP06319 Test Date 3/3/09

LUMINAIRE DATA

Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

ZONAL LUMEN SUMMARY Zone

VL4-232-E Vandal Resistant Close-Fit Wrap 8" × 48" 2-Lamp with Prismatic Plastic Lens 0.88 F32T8 2900 55 Surface 0º = 90  90º = 90 0º = 0.98  90º = 1.18 Length: 4.13 Width: 0.67 Height: 0.20

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

ENERGY DATA

Lumens % Lamp % Fixt. 765 1209 2062 2986 269 284 292 293 3279

13.2 20.9 35.5 51.5 4.6 4.9 5.0 5.1 56.5

23.3 36.9 62.9 91.1 8.2 8.7 8.9 8.9 100.0

INDOOR CANDELA PLOT

RCR

70 59 53 48 44 41 38 35 32 30 28

80 50 30 55 52 48 43 42 37 37 32 33 28 30 25 27 22 25 20 23 18 21 16

10 50 40 33 28 24 21 18 16 15 13

70 57 51 46 42 39 36 34 31 29 28

70 50 30 54 51 46 42 40 36 36 31 32 27 29 24 26 22 24 19 22 18 20 16

10 48 39 32 27 23 21 18 16 15 13

50 50 43 38 34 30 27 25 23 21 20

50 30 48 40 34 30 26 23 21 19 17 16

10 46 37 31 26 23 20 18 16 14 13

56.5%

Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

52 Noncompliant $4.62 based on 3000 hrs. and $0.08 per KWH

AVG. LUMINANCE (Candela/Sq. M.)

COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10

Total Luminaire Efficiency

Average Luminance Angle

Luminaire

0 0 40 32 27 23 20 17 16 14 13 11

0 30 40 45 50 55 60 65 70 75 80 85

0.0

22.5

45.0

67.5

90.0

4306 3041 2484 2220 2043 1992 2060 2210 2249 2151 2056 1867

4306 2966 2419 2145 1898 1702 1604 1579 1559 1604 1720 1949

4306 2998 2611 2443 2290 2129 1987 1894 1807 1773 1902 2335

4306 3175 2993 2899 2800 2741 2716 2680 2654 2722 3273 3610

4306 3326 3293 3279 3285 3347 3446 3507 3581 3789 4750 5068

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

DIMENSIONAL DATA

31/2"

91/2" VL

13/8" 9" VLSC Surface Conduit Entry Box 50" 38" 10" 65/8"

11/16" 81/2"

21/4 Dia. KO

11/16 Dia KO's (4 places)

7/8 Dia. KO's NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 06/19/17 WRAPS / VL © 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com