Wall Mounted Perforated 1, 2-Lamp T5, T5HO, T8, Indirect Distribution Project Information Project Name

Type

Catalog No.

Date

Construction —Fixtures are available with one or two T8, T5 or T5HO lamps.

Features • Perforated housing provides a contemporary appearance for today’s modern interiors • Indirect Luminaire • Product available with either T8, T5, or T5HO lamps • Heavy 20-gauge steel construction for excellent housing rigidity • Controls compatible • Unique connection method ensures housing seams are minimized and consistent • Specular reflector system provides maximum output with wide distribution

—The exact shape of the housing is maintained by the use of an inner structural plate at each socket location. The plate is welded into the housing, ensuring housing tolerances are consistent. —End caps are 18-gauge construction and attach with nuts and bolts. —The reflector is specular aluminum for wide distribution with maximum efficiency.

Finish The housing and all painted parts are treated with a five stage phosphate bonding process before being finished. Parts are then finished with a white powder coat finish for maximum consistent coverage and longevity.

Mounting The WMP mounts directly to and is flush with the wall. A 2" × 3" cutout is provided in the unit to mount to a 2" × 4" junction box. If a junction box larger than 2" in diameter is used, a cover plate must be used to cover the exposed junction box. Key-hole solts on the back of the unit provide additional support. Consult the Installation Sheet for exact dimensions and locations of holes and slots. Labels and Electrical –UL listed 1598. cUL or CSA. Damp location listed. –Prewired with either T5, T5HO, or T8 electronic ballasts. –Quick connect plugs standard. Name: Test #: Efficiency: LER:

WMP1T8-S-WM-E 12589 74.5% 56

Shape and Dimensions 31⁄8" 6¼"

Ordering Information

WMP — Model WMP Wall Mounted Perforated



Example: WMP-8-2T8-PERF-WM-EU-MW



LAMP TYPE AND PROFILE 1T5 One T5 Lamp 2T5 Two T5 Lamps 1T5HO One T5HO Lamp 2T5HO Two T5HO Lamps 1T8 One T8 Lamp 2T8 Two T8 Lamps

row length 4 4' Single 8 8' Single — Indicate row length over 8' in 4' increments Note: Rows over 8' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory.



WM



MOUNTING Method WM Wall Mount

housing type PERF Perforated S Solid AP All Perforated HSLT Horizontal Slot VSLT Vertical Slot

— U 120 277 347

Finish MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.

Voltage 120V-277V 120V 277V 347V

Ballast E Electronic, Instant Start (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ED Electronic, Dimming (Must specify) ESD Electronic, Step Dimming Unless specified, Alera will use fewest ballasts possible.



GCO PSW UB EL EMC NLC GLR GMF

Options Grounded Convenience Outlet (120V only) Pull Chain Switch Upper/Lower Switching Emergency Battery Pack1, 2 One Emergency Circuit2, 3 Night Light Circuit2, 3 Fast Blow Fuse Slow Blow Fuse

Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). Not available with all configurations; some limitations apply. Contact factory for details. 3 One extra feed drop per EMC/NLC. For through wiring, contact factory. 1 2

Page 1/3 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

curves / WMP

Wall Mounted Perforated 1, 2-Lamp T5, T5HO, T8, Indirect Distribution Cross section

3⅛"

3⅛"

6¼"

6¼"

One Lamp

Two Lamp

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

WMP-2T8-PERF-WM-E WMP Architectural Surface Mounted 6.5" × 48" 2-Lamp Wall Mount With Specular Reflector REL-2P32-SC 0.88 F32T8 2900 57 Wall 0º = 0  90º = 0 0º = N/A  90º = N/A Length: 3.38 Width: 0.17 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

90.0 135.0 180.0 225.0 270.0 412 412 1017 952 1076 1003 1113 1007 1137 991 1143 980 1161 974 1152 931 1095 876 1158 724 1187 755 1505 860

412 368 342 344 321 294 225 177 164 145 108 215

412 87 98 212 291 261 225 177 110 72 108 215

412 87 318 371 291 229 187 177 110 145 108 215

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 20 34 66 88 893 1529 2787 3640 3727

0.3 0.6 1.1 1.5 15.4 26.4 48.0 62.8 64.3

0.5 0.9 1.8 2.3 24.0 41.0 74.8 97.7 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12519

RC RW 1 2 3 4 5 6 7 8 9 10

70 56 51 46 42 39 35 33 30 28 26

80 50 30 53 51 47 43 41 37 36 31 32 27 28 23 25 21 23 18 21 16 19 14

10 49 40 33 28 23 20 17 15 13 12

70 48 44 40 36 33 30 28 26 24 22

70 50 30 46 44 40 37 35 32 31 27 27 23 24 20 22 18 20 16 18 14 16 13

10 42 35 29 24 21 18 15 13 11 10

50 32 28 24 22 19 17 15 14 12 11

50 30 31 26 22 19 17 14 13 11 10 9

Indoor Candela Plot 10 30 24 20 17 15 13 11 9 8 7

0 0 1 1 1 1 1 1 0 0 0 0

135

150

165

180 1400

165

150

135

120

120 700

105

105

90

90

75

75 700

60

60 1400 45

30

15

0

270.0-90.0

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

15

30

45

180.0-0.0

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens

64.3% 58 $4.14 based on 3000 hrs. and $0.08 per KWH

Test Date 6/13/00

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

WMP-1T5HO-PERFWM-E WMP Curves 6.5" × 48" 1-Lamp Wall Mount With Specular Reflector FWTSD-155P 0.95 F54T5 4400 61 Wall 0º = 0  90º = 0 0º = N/A  90º = N/A Length: 3.38 Width: 0.17 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

90.0 135.0 180.0 225.0 270.0 262 1017 1052 1060 1078 1078 1087 1064 1041 941 971 1290

262 930 954 954 962 947 899 887 767 724 647 860

262 238 220 212 204 163 150 133 110 145 108 215

262 65 73 159 262 294 225 177 164 145 108 215

262 65 269 371 321 261 187 177 110 145 216 215

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 16 29 59 79 1023 1685 3014 3977 4055

0.4 0.7 1.3 1.8 23.2 38.3 68.5 90.4 92.2

0.4 0.7 1.5 1.9 25.2 41.5 74.3 98.1 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12626

RC RW 1 2 3 4 5 6 7 8 9 10

70 80 73 66 61 55 51 47 43 40 37

80 50 30 76 73 67 62 58 52 51 45 46 39 41 34 36 29 33 26 29 23 27 21

10 70 57 47 40 34 29 25 21 19 16

70 69 62 57 52 47 43 40 37 34 32

70 50 30 66 63 57 53 50 45 44 39 39 34 35 29 31 26 28 23 25 20 23 18

10 61 50 41 35 29 25 22 19 16 14

50 45 40 35 31 27 24 22 20 18 16

50 30 44 37 32 27 24 21 18 16 14 13

Indoor Candela Plot 10 42 35 29 25 21 18 15 13 12 10

0 0 1 1 1 1 1 1 1 0 0 0

135

150

165

180 3000

165

150

135

120

120 1500

105

105

90

90

75

75 1500

60

60 3000 45

30 15 270.0-90.0

0

15 180.0-0.0

30

45

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens

92.2% 63 $3.81 based on 3000 hrs. and $0.08 per KWH

Page 2/3 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Test Date 8/30/00 curves / WMP

Wall Mounted Perforated 1, 2-Lamp T5, T5HO, T8, Indirect Distribution Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

WMP-2T5HO-PERFWM-E WMP Curves 6.5" × 48" 2-Lamp Wall Mount With Specular Reflector FWTSD-155P 0.92 F54T5 4400 102 Wall 0º = 0  90º = 0 0º = N/A  90º = N/A Length: 3.38 Width: 0.17 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

90.0 135.0 180.0 225.0 270.0

562 1730 1859 1934 1953 2025 2061 2083 2136 2099 2158 3009

562 1644 1687 1696 1719 1731 1686 1640 1588 1448 1295 1505

562 476 465 424 379 327 262 222 164 145 108 0

562 108 220 397 466 392 300 222 110 72 0 0

562 108 562 556 437 327 225 133 110 72 0 0

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 30 54 108 148 1523 2726 5164 6872 7019

0.3 0.6 1.2 1.7 17.3 31.0 58.7 78.1 79.8

0.4 0.8 1.5 2.1 21.7 38.8 73.6 97.9 100.0

RCR

Luminaire

Angle

Luminaire Data Test 12620

RC RW 1 2 3 4 5 6 7 8 9 10

70 69 63 57 52 48 44 40 37 34 32

80 50 30 66 63 58 53 51 45 45 39 39 33 35 29 31 25 28 22 25 20 23 18

10 61 50 41 34 29 25 21 19 16 14

70 59 54 49 45 41 37 34 32 29 27

70 50 30 57 55 50 46 44 39 38 34 34 29 30 25 27 22 24 20 22 17 20 16

10 52 43 36 30 25 22 19 16 14 12

50 39 34 30 27 24 21 19 17 15 14

50 30 38 32 28 24 21 18 16 14 12 11

Indoor Candela Plot 10 37 30 25 21 18 16 13 12 10 9

0 0 1 1 1 1 1 1 0 0 0 0

135

150

165

180 3000

165

150

135

120

120 1500

105

105

90

90

75

75 1500

60

60 3000 45

30 15 270.0-90.0

0

15 180.0-0.0

30

45

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Comparative Yearly Lighting Energy Cost per 1000 Lumens

79.8% 63 $3.81 based on 3000 hrs. and $0.08 per KWH

Page 3/3 Rev. 06/26/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Test Date 8/8/00