Y S 5 05A

Report 5 Downloads 143 Views
Ordering information

On-board type

YS5

Y 1

S 2

5 3

05A 4

1Series name 2Single output 3Output wattage 4Output voltage

R

MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT

YS505A 5.0 5V 1.0A

YS512A 5.4 12V 0.45A

YS505A AC85 - 132 1f or DC110 - 170 0.15typ (Io=100%) 47 - 440 or DC 68typ (Io=100%) 15typ (Io=100%)

YS512A

SPECIFICATIONS

INPUT

OUTPUT

Y

PROTECTION CIRCUIT

ISOLATION

ENVIRONMENT

SAFETY AND NOISE REGULATIONS

MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V INRUSH CURRENT[A] ACIN 100V VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] *1 RIPPLE[mVp-p] RIPPLE NOISE[mVp-p] *1 TEMPERATURE REGULATION[mV] 0 to +55C START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[%] HOLD-UP TIME[ms] OVERCURRENT PROTECTION INPUT-FG, OUTPUT OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE

5 12 1 0.45 20max 48max 40max 100max 80max 120max 120max 150max 50max 150max 200max (ACIN 85V, Io=100%) Fixed t5max (Rated input/output, Ta=25 C) 10typ (ACIN 85V, Io=100%) Works over 105% of rating and recovers automatically AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) -10 to +70C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 30minutes each along X, Y and Z axis 490.3m/s2 (50G), 11ms, once each X, Y and Z axis UL60950-1, C-UL Complies with FCC-B

*1 Measured by 20MHz oscilloscope. * Parallel operation with other model is not possible.

G-178

70typ (Io=100%)

YS5 External view

Performance data

¡STATIC CHARACTERISTICS (YS512A)

¡RISE TIME & FALL TIME (YS512A)

Y

20ms/DIV

¡OVERCURRENT CHARACTERISTICS (YS512A)

¡DERATING CURVE

G-179

Ordering information

On-board type

YS10

Y 1

S 2

10 3

05A 4

1Series name 2Single output 3Output wattage 4Output voltage

R

MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT

YS1005A 10.0 5V 2.0A

YS1012A 10.8 12V 0.9A

YS1005A AC85 - 132 1f or DC110 - 170 0.3typ (Io=100%) 47 - 440 or DC 73typ (Io=100%) 15typ (Io=100%)

YS1012A

SPECIFICATIONS

INPUT

OUTPUT

Y

PROTECTION CIRCUIT

ISOLATION

ENVIRONMENT

SAFETY AND NOISE REGULATIONS

MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V INRUSH CURRENT[A] ACIN 100V VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] *1 RIPPLE[mVp-p] RIPPLE NOISE[mVp-p] *1 TEMPERATURE REGULATION[mV] 0 to +55C START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[%] HOLD-UP TIME[ms] OVERCURRENT PROTECTION INPUT-FG, OUTPUT OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE

5 12 2 0.9 20max 48max 40max 100max 80max 120max 120max 150max 50max 150max 200max (ACIN 85V, Io=100%) Fixed t5max (Rated input/output, Ta=25 C) 10typ (ACIN 85V, Io=100%) Works over 105% of rating and recovers automatically AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) -10 to +70C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 30minutes each along X, Y and Z axis 490.3m/s2 (50G), 11ms, once each X, Y and Z axis UL60950-1, C-UL Complies with FCC-B

*1 Measured by 20MHz oscilloscope. * Parallel operation with other model is not possible.

G-180

75typ (Io=100%)

YS10 External view

Performance data

¡STATIC CHARACTERISTICS (YS1012A)

¡RISE TIME & FALL TIME (YS1012A)

Y

20ms/DIV

¡OVERCURRENT CHARACTERISTICS (YS1012A)

¡DERATING CURVE

G-181

Ordering information

On-board type

YS15

Y 1

S 2

15 3

05A 4

1Series name 2Single output 3Output wattage 4Output voltage

R

MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT

YS1505A 15.0 5V 3.0A

YS1512A 15.6 12V 1.3A

YS1505A AC85 - 132 1f or DC110 - 170 0.4typ (Io=100%) 47 - 440 or DC 75typ (Io=100%) 25typ (Io=100%)

YS1512A

SPECIFICATIONS

INPUT

OUTPUT

Y

PROTECTION CIRCUIT

ISOLATION

ENVIRONMENT

SAFETY AND NOISE REGULATIONS

MODEL VOLTAGE[V] ACIN 100V CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V INRUSH CURRENT[A] ACIN 100V VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] *1 RIPPLE[mVp-p] RIPPLE NOISE[mVp-p] *1 TEMPERATURE REGULATION[mV] 0 to +55C START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[%] HOLD-UP TIME[ms] OVERCURRENT PROTECTION INPUT-FG, OUTPUT OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE

5 12 3 1.3 20max 48max 40max 100max 80max 120max 120max 150max 50max 150max 200max (ACIN 85V, Io=100%) Fixed t5max (Rated input/output, Ta=25 C) 10typ (ACIN 85V, Io=100%) Works over 105% of rating and recovers automatically AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) -10 to +70C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 30minutes each along X, Y and Z axis 490.3m/s2 (50G), 11ms, once each X, Y and Z axis UL60950-1, C-UL Complies with FCC-B

*1 Measured by 20MHz oscilloscope. * Parallel operation with other model is not possible.

G-182

78typ (Io=100%)

YS15 External view

Performance data

¡STATIC CHARACTERISTICS (YS1512A)

¡RISE TIME & FALL TIME (YS1512A)

Y

20ms/DIV

¡OVERCURRENT CHARACTERISTICS (YS1512A)

¡DERATING CURVE

G-183