1 typical enlargement - Arlingtonva

Report 47 Downloads 47 Views
LEGEND: LEGEND: STREETSCAPE

E BIKE RACKS

S

BENCH

D

CONCRETE PAVING

T

EVERGREEN TREES (TOTAL 6) FOR REPLACEMENT OF TREE #26.1 APPROVAL NEEDED FROM NEIGHBORING PROPERTY

SOUTH LINCOLN S

TRASH CAN

TREET

LIGHT POLE

UNIT PAVERS

BRICK WALL WITH WOODEN FENCE TYPE 2

: UTILITIES

4'-11"

2'-0"

2'-0"

CONCRETE PAVING

E

4'-3"

TREE PIT MIN 6' WIDE AND 12' LONG WITH GROUND COVERS AND SHRUBS

S

E

E

E

E

E

E

E

E

D T OH

TREE GUARD (TYP.) ON THREE SIDES

EVERGREEN TREES

W

ENLARGEMENT: A

OH

W

LIGHT FIXTURE (TYP.) TYPE A

OH

W W

30'-0"

LANDSCAPE AREA

OH

3

4

1"=10'

ENLARGEMENT:B 1"=10'

2'-3"

BENCH (TYP.)

4'-7"

6'-0"

6'-0"

30'-0"

2'-0" WIDE SCORED CONCRETE PAVEMENT AS CROSSING TO GET FROM PARKING TO CLEAR ZONE

30'-0"

TREE PIT WITH GROUNDCOVERS AND SHRUBS

BIKE RACK (TYP.) TWO (2) AT THIS LOCATION

TREET

ULMUS AMERICANA 'VALLEY FORGE' SEE PLAN FOR QUANTITIES

SOUTH LINCOLN S

REFER ENLARGEMENT 4/L101

30'-0"

TREE PIT WITH GROUNDCOVERS AND SHRUBS "SHY ZONE"

SHY ZONE

REFER ENLARGEMENT 3/L101

REFER ENLARGEMENT 1/L101 T

E

G

6'-0" FURNITUR E& PLANTING ZON E CURB GUTTER PAN

6'-0" "PLANTING & FURNITURE ZONE" 8' WIDE PARKING

PARKING

TREE PIT WITH GROUNDCOVERS AND SHRUBS

2

PLANTER SUBDRAIN

E

TRASH CAN (TYP.)

T

W

EXISTING TRANSFORMERS TO REMAIN

33'-2"

PROPOSED SWM VAULT. SEE CIVIL

E

E

G

T

W

T

W

LIGHT FIXTURE (TYP.) TYPE A

E

W

EXISTING BUS SHELTER TO REMAIN. SURROUNDING CONCRETE CURB TO BE REMOVED. T

T

T

T

T

T

T

T

T

T

G

T

T

T

T

T

BIKE RACK (TYP.) ONE AT THIS LOCATION

30'-0"

24' - 0"

HANDICAP RAMP WITH DETECTABLE PAVING SEE CIVIL FOR RAMP DETAILS.

E

30'-0"

T

W E

W

W

W

W

W

W

W

W

W

W

W

W

W

W

2'-0" WIDE SCORED CONCRETE PAVEMENT AS CROSSING TO GET FROM PARKING TO CLEAR ZONE

SIGHT TRIANGLE SEE CIVIL LIGHT FIXTURE (TYP.) TYPE B

T

W

E

W

G

W

W 6'-0" "CLEAR ZONE" W CONCRETE PAVEMENT WITH 3' X 3' SCORING PATTERN

W

T

G

W

BIKE RACKS TWO AT THIS LOCATION

W

T

W

PROPERTY LINE

6'-0" PLANTING & W W FURNITURE ZONE

W

E

W

W

E

W

W

G

STREET LIGHT TYPE B

W

W

W

W

W

W

W

W

W

W

W

G

W

W

QUERCUS RUBRA SEE PLAN FOR QUANTITIES

G

T

T

G

30'-0"

T

1"=10'

T

W

30'-0"

47'-1"

T

T

T

T

T

E

T

G

T

W W

T

E

G

T

TYPICAL ENLARGEMENT: SOUTH LINCOLN STREET 6'-0" CLEAR ZONE

G

PLANTER SUBDRAIN

6'-0" CLEAR ZO N

6'-0" PLANTING & FURNITURE ZONE

G

30'-0"

POTENTIAL LOCATION OF BIOFILTER FOR AN ALTERNATE CONCEPT OF SWM. SEE CIVIL FOR MORE DETAILS

6'-0" "CLEAR ZONE" CONCRETE PAVEMENT WITH 3' X 3' SCORING PATTERN

SOUTH LINC OLN STREET

30'-0"

CONCRETE PAVING

W

CURB

"SHY ZONE"

GUTTER PAN

COLUMBIA PIKE

1 0

10'

20'

40'

60'

PARKING

TYPICAL ENLARGEMENT: COLUMBIA PIKE 1"=10'

TREE REPLACEMENT: ON SITE

PLANTER CURB

PROPOSE D # TREES

CATEGORY

EQUIVALENT REPLACEMENT VALUE

12

LARGE TREES

12

24

ORNAMENTAL AND EVERGREEN TREES

8

EGRESS GATE

42" GUARD RAIL BUILT-IN PLANTER - 1241 SF; TREES, SHRUBS, PERENNIALS & GROUNDCOVER UNIT PAVING ON STRUCTURE 938 SF

1

TOTAL REPLACEMENT TREES PROVIDED

20

TOTAL REPLACEMENT TREES REQUIRED

4

TOTAL REPLACEMENT DEFICIT

0

TREE REPLACEMENT CALCULATIONS

BENCH

BUILT-IN PLANTER - 543 SF; SHRUBS, PERENNIALS, & GROUNDCOVER (POTENTIAL BIO-RETENTION AREA)

EGRESS GATE

BUILT-IN PLANTER - 706 SF; SHRUBS, PERENNIALS & GROUNDCOVER

BUILT-IN PLANTER - 612 SF; SHRUBS, PERENNIALS & GROUNDCOVER

UNIT PAVING ON STRUCTURE SEAT WALL

BUILT-IN PLANTER - 1370 SF; SHRUBS, PERENNIALS & GROUNDCOVER 938 SF

0

5'

10'

20'

30'

2

20 YEAR CANOPY COVERAGE CALCULATIONS

LEGEND: PAVEMENT DRAIN

TRENCH DRAIN

RIDGE

VARIES 1% TO 1.5%

TRENCH DRAIN

TRENCH DRAIN

PLANTING

PLANTER DRAIN

PLANTING

PLANTING

PLANTING

0

5'

10'

20'

30'

PLANTER CURB

STRUCTURAL FILL

CONCRETE UNIT PAVERS OR OTHER APPROVED SURFACE

3'-6"

PLANTING SOIL

PLANTER CURB

4'-0"

2'-0"

GUARD RAIL

1'-0"

PLANTING SOIL

VARIES SEE PLAN

VARIES 5'-6" AT THE TREE

1

SECTION 1 3/8"=1'-0"

PLANTING SOIL

CONCRETE UNIT PAVERS OR OTHER APPROVED SURFACE

SEAT WALL BEYOND

STRUCTURAL FILL

VARIES SEE PLAN

2

SECTION 1 3/8"=1'-0"

2'-0"

2'-0"

SEAT WALL BEYOND

VARIES SEE PLAN

VARIES SEE PLAN

DRAINAGE GRAVEL

LINE OF ADJACENT CONSTRUCTION

2"

6'-0"

- 81" HAND TIGHT SAND-SWEPT JOINTS ASTM C144 FOR FINE AGGREGATE

1 16

EXPANSION JOINT DELETE DOWEL

2"

6"

UNIT PAVERS

SAND SETTING BED ASTM C33 FOR FINE AGGREGATE

5'-6"

LAYOUT LINE (TYP.)

2"x3" JOIST

3" 8

INSIDE

2"

CIP CONCRETE BASE

6"

7'-0"

7'-0"

4"

OUTSIDE

EDGE RESTRAINT

4"

EQ.

1"x4" BOARDS

ADJACENT PLANTER 1"

1"x4" BOARDS

FORMED KEY NO METAL KEY

TOOLED JOINT, 1 4 DEPTH OF SLAB.

BACKER ROD W/ BUFF COLOR SEALANT.

SEPARATION GEOTEXTILE TURN UP AT EDGES

EQ.

2"x3" JOIST

3 8"

#5x12" REBAR. SLEEVED ONE END. 24" O.C. @ ADJOINING SLABS.

EXPANSION/ISOLATION JOINT (EJ)

4"x4" POST

6x6 W2.0xW2.0 WWF

8"

CONTROL/CONTRACTION JOINT (CJ)

3" 4

PEA GRAVEL FILL (TYP.) STRUCTURAL FILL REFER TO ARCHITECTURAL DETAILS

KEYED CONSTRUCTION JOINT (KJ)

STRUCTURAL SLAB REFER TO ARCHITECTURAL PLANS

NOTES: 1. INSTALL CONTROL JOINTS AT EQUAL INTERVALS OF 5'-0" UNLESS OTHERWISE INDICATED. 2. INSTALL EXPANSION JOINTS @ 20'-0" INTERVALS MAX., UNLESS OTHERWISE INDICATED, AND WHERE SLAB MEETS ANY ADJACENT STRUCTURE. 3. TOOL ALL EXPOSED EDGES W/ 14" RADIUS. 4. RECESS EXPANSION JOINTS 14" BELOW FINISH GRADE. 5. SAWCUT JOINTS ARE PROHIBITED.

1"

SECTION C

7

WATERPROOFING & SLAB DRAINAGE REFER TO ARCHITECTURAL DETAILS

8'-0" O.C. (TYP.) 4"

4" 10"

CONCRETE COLLAR

ELEVATION

WOODEN FENCE: TYPE 1

CONCRETE JOINTING

4

1/2"=1'-0"

NOTES: 1. EDGE RESTRAINT: 221 x 4 x 3 16" GALVANIZED STEEL ANGLE, AFFIXED TO TOP OF SLAB W/ EXPANSION ANCHORS, MIN. 24" O.C. INSTALL PAVER COURSES IN STRAIGHT LINES AND TRUE ARCS AND TANGENTS. 1. FOR ALL CUTS, REPLICATE EDGE CONDITION OF UNCUT UNIT. 2. INSTALL CUT UNITS MIN. 10 UNITS FROM ENDS OF COURSE. CUT UNITS LESS THAN 21 PAVER DIMENSION ARE PROHIBITED. REMOVE CUT UNIT AND 2 ADJACENT UNITS; INSTALL 3 EQUAL CUT UNITS. 3. FOR RADIAL COURSES, INSTALL SYMMETRICALLY CUT UNITS AT REGULAR INTERVALS. CUT EACH UNIT FOR SMALLER RADII AND AS DIRECTED BY ARCHITECT.

1 1/2"=1'-0"

UNIT PAVING ON STRUCTURE

1

2'-0"

1 1/2"=1'-0"

TW COPING

2'-0"

BRICK VENEER MATCH ARCHITECTURE REINFORCED CMU BACKER WALL 3 8"

SEALANT JOINT

LINE OF ADJACENT CONSTRUCTION

ADJACENT PAVING

2"

6"

- 81" HAND TIGHT SAND-SWEPT JOINTS ASTM C144 FOR FINE AGGREGATE

1 16

EXPANSION JOINT DELETE DOWEL

3" MIN.

2"

OUTSIDE

UNIT PAVERS

SAND SETTING BED ASTM C33 FOR FINE AGGREGATE

INSIDE PL

SEPARATION GEOTEXTILE TURN UP AT EDGES

2"x3" TOP RAIL

4"

2"x3" TOP RAIL

ADJACENT PLANTER

1"x4" BOARDS

ELEVATION: A

BRICK VENEER AS/ ARCHITECTURE

CONNECT FENCE POST TO MASONRY WALL WITH GALVANIZED STEEL PLATE 38" THK. EMBEDDED IN THE MASONRY BELOW

2"

1" 4"

1'-6"

CIP CONCRETE BASE

6x6 W2.0xW2.0 WWF

6"

4'-3" 2'9"

CAST STONE COPING AS/ARCH.

VARIES

4"

4"

7'-0"

1"x4" BOARDS 4"x4" POST

EDGE RESTRAINT

PEA GRAVEL FILL (TYP.) WATERPROOFING & DRAINAGE BOARD (SEE ARCHITECTURAL DRAWINGS)

VENEER AS/ ARCHITECTURE

8'-0" O.C. (TYP.)

1'-0"

STRUCTURAL SLAB (SEE ARCHITECTURAL DRAWINGS)

5

2"

SEAT WALL

2

3/4"=1'-0"

1 1/2"=1'-0"

SECTION: B LINE OF ADJACENT WALL OR CURB CIP CONCRETE MEDIUM BROOM FINISH SWEEP PERPENDICULAR TO DIRECTION OF TRAFFIC

6' - 8' CC

WALL EDGES

4"

C.I.P. RCC SUPPORT WALL OR MASONRY SUPPORT WALL AS PER STRUCTURAL ENGINEER.

4"

8"

4"x4" POST

6"

DRAINAGE BOARD. CLOSE & ANCHOR TO WALL PER MFR'S WRITTEN SPECIFICATIONS

2"x3" WOODEN RAIL

2"

CAST STONE CURB

INSIDE

6x6 W2.1xW2.1 WWF W/ CONTINUOUS CHARS 6 MIL VAPOR BARRIER COMPACTED DENSELY GRADED AGGREGATE VDOT 21-A (TYP.)

OUTSIDE

4"

PLAN

4"

NOTES: 1. REFER TO PLAN FOR JOINT TYPES.

8

WOODEN FENCE: TYPE 2 1/2"=1'-0"

COMPACTED SUBGRADE

UNIT PAVING ON GRADE

8"

1"x4" BOARDS

COMPACTED AGGREGATE VDOT 21-A

6

PLANTER CURB 1 1/2"=1'-0"

3

CONCRETE PAVING 1 1/2"=1'-0"

COMPACTED SUBGRADE PER SPECIFICATIONS

6'-0" 1'-53 4"

4" O.C. TYP. 1 1 2"x2" TUBE STEEL 1 2" TUBE STEEL RING

2"x1" TUBE STEEL 1'-4"

2" x 2" TUBE STEEL ADJACENT CONDITION SEE PLAN

CURB & GUTTER

2" x 2" POST STAINLESS STEEL EXPANSION ANCHORS (TYP.)

NOTES: 1. ALL COMPONENTS ARE GALVANIZED STEEL, PAINTED BLACK TO MATCH EXISTING, UNLESS OTHERWISE INDICATED. 2. ALL CONNECTION ARE SHOP WELDED UNLESS OTHERWISE INDICATED. 3. GRIND SMOOTH ALL WELDS AND PRIOR TO FINISHING.

1

3 8"

TREE GUARD: CROSS SECTION 1"=1'-0"

VARIES SEE PLAN EQ.

EQ. 4" O.C. TYP.

1'-3"

1'-3" 1 1 2"x2" TUBE STEEL 1 2" TUBE STEEL RING

1 2"

2" x 2" TUBE STEEL

1" 1'-32

1" 1'-32

2"x1" TUBE STEEL

NOTES: 1. ALL COMPONENTS ARE GALVANIZED STEEL, PAINTED BLACK TO MATCH EXISTING, UNLESS OTHERWISE INDICATED. 2. ALL CONNECTION ARE SHOP WELDED UNLESS OTHERWISE INDICATED. 3. GRIND SMOOTH ALL WELDS AND PRIOR TO FINISHING.

2

2" x 2" POST STAINLESS STEEL EXPANSION ANCHORS (TYP.) 3 8"

TREE GUARD: LONGITUDINAL SECTION 1"=1'-0"

1" 1'-94 COMPOSITE WOOD MEMBERS

STEEL SUPPORT ADJACENT PAVING

8"

1'-6"

ADJACENT LANDSCAPE AREA

BASE PLATE, BOLTED TO CONCRETE FOOTING PLANTER CURB BEYOND

3

BENCH TYPE II SECTION 1"=1'-0"

3" MIN.

NOTES NTS

BENCH ANCHOR

NOTES: 1. ALL FABRICATED METAL COMPONENTS ARE STEEL SHOTBLASTED, ETCHED, PHOSPHATIZED, PREHEATED, AND ELECTROSTATICALLY POWDER-COATED WITH T.G.I.C. POLYESTER POWDER COATINGS. PRODUCTS ARE FULLY CLEANED AND PRETREATED, PREHEATED AND COATED WHILE HOT TO FILL CREVICES AND BUILD COATING FILM. COATED PARTS ARE THEN FULLY CURED PRIOR TO COATING, AVERAGES 8-10 MILS THICKNESS. 2. BASIS OF DESIGN: VICTOR STANLEY RB-28 3. OPTIONS: FREESTANDING, 1 ARM AT EACH END 4. WEIGH 235 POUNDS

1

BENCH TYPE I

6

STREETLIGHT

1A

NTS

STREETLIGHT - TWIN ARM NTS

1 1/2"=1'-0"

EXISTING RECEPTACLE (VARIES)

POLE

SIMILAR TO

BASE COVER

BENCH ANCHOR

GROUT SOLID. SLOPE TO DRAIN. ADJACENT PAVING

UNIT PAVING SIM.

EXPANSION JOINT (SIM.)

NOTES: 1. ADJUST LEVELING FEET TO SET RECEPTACLE PLUMB. 2. ANCHOR TO CONCRETE BASE AS INDICATED. 3. ORIENT RECEPTACLES TOWARD ADJACENT CURB AND VERIFY 4. SIDE DOOR, WHERE PRESENT, HAS FULL RANGE OF UNIMPEDED MOTION.

TRASH RECEPTACLE

5

PRESET CONDUIT & GROUNDING; REFER TO SITE ELECTRICAL & MFR'S WRITTEN SPECIFICATIONS

1"=1'-0"

1'-93 8" 121" O.D. SCHEDULE 40 GALVANIZED STEEL PIPE 3 8"

MAX. SEALANT JOINT (TYP.)

3'-0"

REBAR LUGS BY MRF.

1" 68 MIN.

4

NOTES: 1. THIS DETAIL IS FOR PAVEMENT CONDITIONS ADJACENT TO LIGHT POLE. FOOTING DESIGN BY OTHERS. 2. VERIFY FOOTING DIAMETER W/ LIGHT MRF. & STRUCTURAL REQUIREMENTS. 3. REFER TO SITE ELECTRICAL PLANS/SPECIFICATIONS & POLE MFR. FOR ADDITIONAL INFORMATION.

10"

8

PROVIDE BLACK COLOR FOR ALL STREET FURNISHINGS INCLUDING BENCHES, TRASH RECEPTACLES, BIKE RACKS, LIGHT POLES, TREE FENCE.

1" 1'-28

1)

NOTE: 1. ALL HARDWARE TO BE GALVANIZED OR STAINLESS STEEL. PAINT TO MATCH LEG. 2. PROVIDE (1) ANCHOR & WASHER PER ANCHOR HOLE, AS REQUIRED BY BENCH MFR; DROP-IN ANCHOR OR SLEEVE ANCHOR W/ ACORN NUT.

BIKE RACK NTS

THICKENED SLAB

3

POLE LIGHT BASE 1" = 1'-0"

2

STREETLIGHT - POLE NTS

4

7

1

SINGLE STEM TREE PLANTING (SIM.) ROOT FLARE TREE UPLIGHT IRRIGATION PIPE

4'-0" MIN.

2'-6" MIN.

MULCH

ON STRUCTURE SOIL MIX; REFER TO SPECIFICATIONS 6 x 6 TIMBER DEADMAN, 3'-0" LENGTH w/ 3/8"x4" EYEBOLTS; GUY AS INDICATED FILTER FABRIC DRAINAGE AGGREGATE

4" MIN.

DRAINAGE BOARD & WATERPROOFING; REFER TO ARCHITECTURAL DETAILS. STRUCTURAL SLAB; REFER TO STRUCTURAL PLANS NOTES: 1. INSTALL INSULATION AND/OR TOPPING SLAB, AS APPROVED BY ARCHITECT, TO PROVIDE POSITIVE DRAINAGE TO ALL PLANTING AREA DRAINS. WATERPROOF PER ARCHITECTURAL DETAILS.

PRESET CONDUIT; REFER TO ELECTRICAL PLANS DRAIN; LOCATION/QUANTITES VARY

2

6

3

PLANTING NOTES

PLANTING SPECIFICATIONS

LANDSCAPE MAINTENANCE MANAGEMENT PROGRAM