6” LED RETROFIT MODULE

Report 3 Downloads 178 Views
N1.5.0

6” LED RETROFIT MODULE Project:

DOWNLIGHT RETROFIT FOR STANDARD 6” RECESSED HOUSINGS

Fixture Type: Location:

V6RL3K-WH

Contact/Phone:

PRODUCT DESCRIPTION Energy efficient LED retrofit module fits into standard 6” IC or non-IC recessed housings • Replaces 65W incandescent lamp while consuming less than 13W • Dimmable with most standard incandescent dimmers and electronic low voltage dimmers • LED retrofit module is designed to provide 35,000 hours of life • 3 year warranty

PRODUCT SPECIFICATIONS LED Retrofit Module All-in-one design where LED light engine mounts directly to trim for ease of installation into existing 6” recessed housings with medium base sockets. LED Light Engine LEDs and driver are mounted directly to upper housing with finned aluminum heat sink designed to provide superior thermal management and ensure long life • 3000K LED color temperature • 80 CRI typical • 120 volts AC at 60Hz.

DIMENSIONS 4 7/16"

LED Driver Accommodates 120 volts AC at 60Hz • Driver is dimmable with most standard incandescent dimmers • For best results, electronic low voltage dimmers are recommended • Refer to the next page for Juno qualified dimmers. Socket Adapter Fixed medium screw base adapter provided attached directly to LED trim module. Trim Die-cast aluminum splay trim with white finish • Diffusing lens conceals the LEDs from direct view and provides uniform aperture luminance.

6 1/8"

Life Rated for 35,000 hours at 70% lumen maintenance. Labels Energy Star qualified • UL and cUL classified for use with most standard UL listed 6” recessed incandescent housings; see below for specific compatibility requirements • Suitable for damp locations. Testing All reports are based on published industry procedures; field performance may differ from laboratory performance. Product specifications subject to change without notice.

INSTALLATION

9/16" (TO LENS)

7 5/8"

PERFORMANCE DATA Input Voltage Input Power

The LED retrofit module is provided with torsion springs as standard. An accessory kit is available for use in housings that do not have torsion spring retaining brackets.

Frequency EMI/RFI

COMPATIBLE HOUSINGS The V6RL retrofit module is compatible with most 6” recessed housings measuring at least 6-3/4” high with an inside diameter between 6” and 6-3/4”. Removal of the housing socket plate or socket mounting bracket may be required in order for the trim to fit properly. If housing does not have torsion spring brackets, the V6RL-TRB accessory is required. Compatible housings include, but not limited to:

Minimum starting temp Lumens CRI LED CCT LPW

VuLite housings:

V6IC and V6TC Series

Juno housings:

IC2 and TC2 Series, IC22 Series, IC23 Series

Halo housings:

H7 Series

Thomas housings: PS1 and PS3 Series Capri housings:

QL1 Series

Lithonia housings: L7X and LC6 Series

REV-4/11

5 7/8" APERTURE

120V 12.9W 60Hz FCC Title 47, Part 15 Class B (consumer) -30°C (-22°F) 587 Typical 80 3000K 45

PRODUCT CODES Catalog Number

Description

V6RL3K-WH

6” LED retrofit module, 3000K

ACCESSORIES Catalog No. V6RL-TRB

Description Torsion receiver bracket kit to install V6RL into housings that do not have torsion receiver brackets

To order, specify catalog number.

N1.5.0

6” LED RETROFIT MODULE DOWNLIGHT RETROFIT FOR STANDARD 6” RECESSED HOUSING

V6RL3K-WH DIMMER COMPATIBILITY Dimmable with most standard incandescent dimmers. For best results, electronic low voltage dimmers are recommended. Dimming range depends on dimmer model with one fixture load minimum to maximum rated load for dimmer. Compatible dimmers include but are not limited to the following Juno qualified dimmers: INCANDESCENT AND MAGNETIC LOW VOLTAGE DIMMERS

ELECTRONIC LOW VOLTAGE DIMMERS

Lutron® Model Numbers: Glyder® GLV Series Diva® D/DV/DVLV Series Ariadni® AY Series* Skylark® S/SLV Series TG Series Ceana® CNLV Series*

Lutron® Model Numbers: Nova T ® NTELV Series* Skylark® SELV Series* Diva® DVELV Series Maestro® MAELV Series* Faedra® FAELV Series* Spacer System® SPSELV Series*

Leviton® Model Numbers: Illumatech® IP106 Series

Leviton® Model Numbers: Illumatech® IPE04 Series (Dimmer has manual trim adjustment for low end of dimming range to achieve 5% dimming)

*Juno recommended dimmers

WHOLE HOUSE INTEGRATED CONTROL SYSTEMS Schneider Electric C-Bus

PHOTOMETRICS PHOTOMETRIC REPORT Test Report #: LTL22327 Catalog No: V6RL3K-WH Luminaire Spacing Criterion: 1.10 Luminaire LPW: 45.9

60 120 180 240 300

CANDLEPOWER DISTRIBUTION (Candelas) Degrees Vertical 0 5 15 25 35 45 55 65 75 85 90

0˚ 311 308 289 251 195 135 85 48 20 4 0

AVERAGE INITIAL FOOTCANDLES Multiple Units (Square Array, 60’x60’ room)

Ceiling 80% Wall 50% Floor 20% Spacing RCR1 RCR3 RCR5 4.0´ 40 32 26 5.0´ 25 20 17 6.0´ 18 14 12 7.0´ 14 12 9 8.0´ 11 9 7 9.0´ 9 7 6 10.0´ 6 5 4

ZONAL LUMEN SUMMARY Zone 0 - 30° 0 - 40° 0 - 60° 0 - 90°

Lumens 225 347 528 601

%Lamp N/A N/A N/A N/A

%Fixture 37.5 57.7 87.7 100.0

INITIAL FOOTCANDLES (One Unit, 13.1W , 83.2° Beam) Distance to Illuminated Plane Footcandles (Feet) Beam Center 4 19.4 6 8.6 8 4.9 10 3.1

Beam Diameter 7.1’ 10.7’ 14.2’ 17.8’

LUMINANCE (Average cd/m2) Degrees 45 55 65 75 85

Average Luminance 13070 10080 7670 5377 3321

1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792-7335 • Fax (905) 792-0064 Visit us at www.junolightinggroup.com Printed in U.S.A. ©2011 Juno Lighting, LLC.