80mm sq. - Sanyo Denki

Report 5 Downloads 80 Views
80

9CRB type

High Airflow Counter Rotating Fan ■ Features

High Airflow and High Static Pressure The maximum airflow increased by approximately 22% compared with our conventional counter rotating fan, while maintaining equivalent maximum static pressure.* It's a perfect cooling solution especially for densely-packed equipment.

Suitable for 2U Devices Measuring 80 mm square, this new fan is ideal for 2U sized equipment. *: Our conventional counter rotating fan is 80 x 80 x 80 mm“San Ace 80”9CRA type, Model No. 9CRA0812P8G001.

80×80×80 mm ■ Specifications The following nos. have PWM controls, pulse sensors. PWM Operating Expected Rated voltage Operating Rated current Rated input Rated speed [min-1] Max. airflow Max. static pressure SPL life temperature voltage range duty cycle 3 / min] [CFM] [V] [A] [W] Inlet Outlet [m [Pa] [inchH 2O] [dB(A)] (Note 3)[h] (Note 1,2) [V] [ ℃] [%]

Model No.

9CRB0812P8G001

12

10.8 to 13.2

100

9.2

20

0.17

110.4

14,600 12,200

2.04

2,000

5.5

1,670

0.7

194

1,150

24.7

21.6

4.6

80

0.09

24

40,000/60℃ -20 to +70 (70,000/40℃)

Note1: PWM frequency: 25 kHz Note2: Fan does not rotate when PWM duty cycle is 0%. Note3: Expected life at 40℃ ambient is just reference value. Pulse Sensor

Available options:

■ Common Specifications □ Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame, Impeller: Plastics (Flammability: UL94V-0) □ Expected life ・・・・・・・・・・・・・・・・・・・・・ Refer to specifications (L10: Survival rate: 90% at 60℃, rated voltage, and continuously run in a free air state) □ Motor protection system ・・・・・・・・・・ Current blocking function and reverse polarity protection □ Dielectric strength ・・・・・・・・・・・・・・・・ 50 / 60 Hz, 500 VAC, 1 minute (between lead conductor and frame) □ Sound pressure level (SPL) ・・・・・・・・ Expressed as the value at 1 m from air inlet side □ Operating temperature ・・・・・・・・・・・・ Refer to specifications (Non-condensing) □ Storage temperature ・・・・・・・・・・・・・・ -30℃ to +70℃ (Non-condensing)

+ Red ○ - Black Sensor: Yellow Control: Brown □ Lead wire ・・・・・・・・・・・・・・・・・・・・・・・・ Inlet: ○

Outlet: ○ + Orange ○ - Gray Sensor: Purple Control: White

□ Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 430 g

■ PWM Duty - Speed Characteristics Example

■ Airflow - Static Pressure Characteristics

→ Static pressure

5

4

3

(Pa) 1,400

・ Operating voltage range (inch H2O)

12 VDC PWM duty cycle 100%

1,200

5

→ Static pressure

(inch H2O)

1,000 800 600

2

60% 400

1

0

200

0

4

3

2

3

4

5

0 20 40 60 80 100 120 140 160 180 200

→ Airflow

6 (m3 / min) (CFM)

(min-1) 16,000

PWM duty cycle 100% 13.2 V 12 V

1,000

12,000

10.8 V

800

2 400 1

0

14,600 min-1 12,200 min-1 Inlet side

10,000 8,000 6,000

Outlet side

4,000

200

0

Voltage: 12 VDC PWM frequency: 25 kHz

14,000

1,200

600

20% 1

(Pa) 1,400

Speed

・ PWM duty cycle

2,000 1

2

3

4

5

0 20 40 60 80 100 120 140 160 180 200

→ Airflow

6 (m3 / min) (CFM)

0

PWM duty cycle

100 (%)

■ PWM Input Signal Example Input signal waveform

■ Example of Connection Schematic

VIH=4.75 V to 5.25 V

DC fan input voltage

VIL=0 V to 0.4 V

VIH

+ ○

Inside of DC fan

PWM duty cycle (%) = T1 ×100 T PWM frequency 25 (kHz) = 1 T

5V

Source current (Isource) : 2 mA max. at control voltage 0 V

VIL

10kΩ

Sink current (Isink) : 2 mA max. at control voltage 5.25 V

Control

Control terminal voltage: 5.25 V max. (Open circuit)

T1

PWM input signal

When the control lead wire is open, the fan speed is the same as the one at a PWM duty cycle of 100%. Either TTL input, open collector or open drain can be used for PWM control input signal.

T

Isource Isink

22Ω 20kΩ

- ○

■ Specifications for Pulse Sensors Output circuit: Open collector Inside of DC fan

Output waveform (Need pull-up resistor) In case of steady running

VCE=+13.8 V max. Ic=5 mA max. [VCE (SAT) =0.6 V max.]

+ ○

T1 to 4≒ (1/4) T0

(One revolution) T0

Sensor Pull-up resistor

T1

Pull-up voltage

Ic

T3

N=Fan speed (min-1)

T4

VOH VOL

Sensor output (VCE)

- ○

T2

T1 to 4≒ (1/4) T0=60/4N (sec)

0V

■ Dimensions (unit: mm) Outlet side Lead wire AWG22 UL1430

Mounting hole

80±1 (4)

(4)

80±0.5 71.5±0.5

300

71.5±0.5

(10) +30 0

80±0.5

Inlet side 4-φ4.5±0.5

4-φ4.5±0.5

Rotating direction

Airflow direction

Mounting hole

Rotating direction

■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm) Inlet side, Outlet side 78.5 4-φ4.5

78.5

71.5±0.3

φ 90

71.5±0.3

Notice

●Please read the "Safety Precautions" on our website before using the product. ●The products shown in this catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. ●To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. 3-33-1 Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan TEL: +81 3 5927 1020

http://www.sanyodenki.com

The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. “San Ace” is a trademark of SANYO DENKI CO.,LTD. Specifications are subject to change without notice. CATALOG No. C1055B001 ‘15.11